Xenon lamp aging test chamber full spectrum weather resistance testing equipment complies with GB/T16422.2 standard
Category:
Instrumentation/Test chamber and climate environment equipment/Damp heat test chamber
Model:
JX-XD
Brand:
Juxin Instrument
spectral range:
290–800nm
reference standard:
GB/T 16422.2, ISO 4892-2, ASTM G155
Light source type:
Xenon arc lamp
Simulated environment:
Light heat moisture rain coupling
Acceleration multiplier:
Weeks equivalent to 1-5 years outdoors
humidity range:
20%-98%RH
application field:
Material weather resistance test
Device Type:
Full spectrum aging testing machine
Retail Price
10,000,000.00USD
重量
kg
- Product Description
-
spectral range 290–800nm
reference standard GB/T 16422.2, ISO 4892-2, ASTM G155
Light source type Xenon arc lamp
Simulated environment Light heat moisture rain coupling
Acceleration multiplier Weeks equivalent to 1-5 years outdoors
humidity range 20%-98%RH
application field Material weather resistance test
Device Type Full spectrum aging testing machine
Description :
Xenon lamp aging test chamber is a high-end environmental testing equipment that uses xenon arc lamps and precision filtering systems to simulate the full spectrum of sunlight. It mainly solves the problem of weather resistance evaluation of materials under long-term outdoor exposure, and is suitable for accelerated aging testing of non-metallic materials such as plastics, coatings, rubber, textiles, etc. This device simulates ultraviolet, visible, and near-infrared light in the 290-800nm wavelength range, synchronously integrates temperature and humidity control, spraying, and condensation functions, and truly reproduces the aging environment of outdoor light heat moisture rain coupling. Compared to a single UV aging chamber, the xenon lamp aging test chamber can more comprehensively reflect the performance changes of materials in actual use, and is the gold standard equipment for material weather resistance testing. It is widely used in the quality control process of scientific research institutions, quality inspection agencies, and production enterprises.
The core specifications of the xenon lamp aging test chamber lie in its light source system and control system. The light source adopts a long arc xenon lamp, combined with a precision filter, to ensure that the spectral energy distribution meets the solar standard. The temperature control range is usually 35 ℃ -100 ℃ for blackboard temperature, 10 ℃ -80 ℃ for box air temperature, and 20% -98% RH for humidity. The sprinkler system can simulate rainfall effects, while the condensation function simulates dew formation, alternating between the two to exacerbate aging effects. The equipment complies with multiple international and domestic standards such as GB/T 16422.2, ISO 4892-2, ASTM G155, SAE J2527, etc. The rack is usually made of stainless steel or cold-rolled steel plate with spray coating treatment, which has strong corrosion resistance. The observation window adopts multi-layer tempered glass, which facilitates real-time monitoring of the sample status. The design of the xenon lamp aging test chamber emphasizes stability and repeatability to ensure the accuracy and reliability of test data.
When selecting a xenon lamp aging test chamber, it is necessary to clarify the testing standards and sample characteristics. If the testing standards explicitly require full spectrum simulation or involve color change evaluation, the xenon lamp aging test chamber should be preferred over the ultraviolet aging chamber. For materials sensitive to light such as car interiors and exterior coatings, xenon lamp aging test chambers are essential equipment. Attention should be paid to distinguishing between air-cooled and water-cooled xenon lamps. The air-cooled type is relatively easy to maintain, while the water-cooled type has better spectral stability but a complex structure. If only the impact of the ultraviolet band needs to be evaluated and is cost sensitive, a ultraviolet aging chamber can be considered, but its data correlation is lower than that of a xenon lamp aging test chamber. When selecting, attention should also be paid to the accuracy of irradiance control, temperature and humidity uniformity, and the coverage range of the sprinkler system to ensure that the testing requirements under specific working conditions are met and to avoid testing deviations caused by insufficient equipment performance.
The daily maintenance of the xenon lamp aging test chamber is crucial to ensure testing accuracy. During installation, it is necessary to ensure that there is sufficient heat dissipation space around the equipment and that the power supply is well grounded. In daily use, regularly clean the xenon lamp filter to prevent dust from affecting the spectral transmittance. Monitoring the usage time of xenon lamps usually requires replacing the lamp tube after 1000-2000 hours to maintain stable irradiance. Regularly check the water quality of the humidification water tank and recommend using deionized water to prevent scaling and blockage of the pipeline. The spray nozzle is easy to be blocked, so it needs to be cleaned regularly to ensure uniform spray. Common faults include irradiance alarm, temperature and humidity loss of control, etc., which are often caused by sensor drift or actuator failure, and require regular calibration of sensors. Proper maintenance of the xenon lamp aging test chamber can extend the service life of the equipment, ensure the validity of data equivalent to 1-5 years of outdoor aging testing for several weeks, and provide reliable basis for material research and development.
AfterSalesService :
全程一对一专属对接,实时在线快速响应。故障问题 2 小时提供解决方案,紧急上门需求,省内 24 小时、省外 48 小时安排技术人员上门处理,高效解决设备各类问题,保障生产稳定运行。Key words: