Supply high air volume vortex high-pressure blower, full air annular high-pressure fan, aluminum alloy vortex high-pressure air pump
Supply high air volume vortex high-pressure blower, full air annular high-pressure fan, aluminum alloy vortex high-pressure air pump

Supply high air volume vortex high-pressure blower, full air annular high-pressure fan, aluminum alloy vortex high-pressure air pump

Category:

Environmental Protection/Fan exhaust equipment/High pressure blower

Model:

2RS 330 A16

Brand:

Colsen

Retail Price

1,300.00USD


重量

kg

  • Product Description
  • Description :

    Supply high air volume vortex high-pressure blower, full air annular high-pressure fan, aluminum alloy vortex high-pressure air pump

    Vortex fan:It is a vortex type high-pressure fan mainly used for its blowing and suction functions, and is applied in the mechanical equipment industry, such as printing machinery, packaging machinery, food machinery, textile machinery, PCB equipment, industrial vacuum equipment, cleaning and drying equipment, leather cutting equipment, laser equipment, woodworking machinery, electroplating equipment, swimming pool equipment, environmental protection equipment, breeding equipment, sewage treatment equipment, plastic auxiliary equipment, welding waste gas suction, powder particle conveying, etc.

    The purpose of the packaging machine vacuum high-pressure fan is:The high-pressure fan is mainly composed of the following six parts: motor, air filter, high-pressure fan body, air chamber, base (also serving as oil tank), and drip nozzle. The high-pressure fan relies on the eccentric operation of the rotor biased inside the cylinder, and changes the volume between the blades in the rotor slot to suck in, compress, and discharge air. During operation, the pressure difference of the blower is used to automatically deliver lubrication to the oil drip nozzle, which drips into the cylinder to reduce friction and noise, while also keeping the gas inside the cylinder from flowing back. This type of high-pressure fan is also known as a slide type high-pressure fan. High pressure fans mainly transport clean air, clean coal gas, sulfur dioxide, and other inert gases. It can also produce and transport other flammable, explosive, corrosive, toxic, and special gases as needed. Therefore, it can be widely used in metallurgy, chemical industry, fertilizer, petrochemical, food, building materials, petroleum, mining, textile, gas station, pneumatic conveying, used in chemical plants, coal mines, tunnels, boilers, canning, glass industry, ventilation and exhaust, automatic cleaning, packaging, fish pond oxygen supply, aeration, garbage decomposition, gas conveying, gas conveying, environmental protection breeding, etc. Various industrial sectors such as sewage treatment.

      The specialized vacuum pump adopts advanced design technology and is made of high-temperature resistant insulation materials. It can ensure the safe operation of the motor in high-temperature environments, without aging or burning out, with high reliability, low maintenance, and long life. During the work process, the efficiency of the work has been improved, maintenance costs have been reduced, and energy consumption during shutdown and start-up has been minimized. Overall reduction reduces waste of resources. The gas transported by the fan is air or other non self igniting, non exploding, non entangling, harmless to the human body, and non corrosive to steel materials. It can also be used to transport non corrosive, non self igniting, and non viscous hot gases, vapors, and smoke in various industries. Precautions for using a vortex high-pressure fan: Regardless of the brand of high-pressure fan, two aspects of protection are required: pressure and dust. For pressure, a pressure relief valve is often used, which is an unloading valve. When the operating pressure of the high-pressure fan exceeds the set pressure of the pressure relief valve, the pressure relief valve will automatically open to release the excess pressure and protect the high-pressure fan. For dust, filters are often used. It often uses filter cartridges with different filtration accuracies according to different usage scenarios. Different filter cartridges have different maintenance methods and service lives, which need to be clarified when ordering. In some special occasions, special protection is also necessary: for example, when using in a sealed environment, attention should be paid to ventilation and heat dissipation; When the ambient temperature (intake temperature is relatively high), it is more important to pay attention to ventilation and heat dissipation, or choose a high-pressure fan that allows for a higher intake temperature (such as a Colson ring blower that allows for an intake temperature of up to 130 ° C); For certain brands of high-pressure fans, there may be their own usage recommendations. Before purchasing, it is important to have a detailed understanding.

    Aerobic vortex air pump Specifications:

      Three phase voltage power: 0.25 KW、0.4KW、0.7KW、0.85KW、1.1KW、1.3KW、1.5KW、1.6KW、2.2KW、3KW、4KW、5.5KW、7.5KW、8.5KW、11KW、12.5KW、15KW、18.5KW、20KW、25KW; Single phase voltage power: 0.2KW, 0.4KW, 0.55K, 0.75KW, 0.85KW, 1.1KW, 1.3KW, 2.2KW; Wind pressure: 50mbar-1010mbar; Airflow: 40m3/h-3000m3/h. For the convenience of selecting different specifications, both single-stage and two-stage models are available; Frequency: 50HZ/60HZ Voltage: 110V-615V, suitable for use in all countries. If special voltage is required, it can be customized according to requirements; Pressure relief valve: RV-01 RV-02 (for use with); Filters: MF08, MF10, MF12, MF16, MF20, MF32; Silencer interface sizes: 1.25 inches, 1.5 inches, 2 inches, 2.5 inches, 4 inches

    Reasons and solutions for malfunction of vortex fan operation:

      1. Fault phenomenon

      The motor cannot start, even if it can start without load, the speed slowly increases and there is a buzzing sound; The motor emits smoke and heat, accompanied by a burning smell.

      2. Inspection results

      Remove the motor end cover and you can see that 1/3 or 2/3 of the pole phase windings at the end of the winding are either burnt or have turned dark brown.

      3. Causes and Solutions of Malfunctions

      1. Poor contact or mechanical damage to the fuse circuit of the motor power supply circuit, resulting in the melting of a certain phase fuse.

      2. The three-phase fuse specifications of the motor power supply circuit are different, and the fuse with smaller capacity burns out. The fuse should be replaced with the same specification according to the power of the motor.

      Poor contact (burning or loosening) of switches (isolating switches, rubber cover switches, etc.) and contactors in the power supply circuit of the 3 motors. Repair and adjust the moving and stationary contacts to ensure good contact.

      4. A certain phase of the line is missing. Identify the broken wire and connect it securely.

      5. Poor contact caused by virtual welding between the winding connections of the electric motor. Carefully check the connection wires of the motor winding and weld them firmly.

    Kind Reminder:

      Dear customers and friends, in order to provide you with a better shopping experience, please contact our online customer service before placing an order to check if there is any stock available. [Offline sales channels] to avoid unnecessary trouble for you.

      As the products sold in our store belong to heavy goods, transportation is carried by third-party cooperative logistics. Each shipment is insured with cargo insurance. To avoid damage to the goods during transportation, customers are requested to check the integrity of the outer packaging before receiving the goods. If there is any damage, please contact our customer service in a timely manner and refuse to accept the goods. We will then resend the goods.

      Our store supports inappropriate return and exchange services. The requirement for return and exchange is that it cannot affect secondary sales. For serious issues such as use, damage, oil stains, etc., return and exchange services are not supported. The cost of return and exchange will be borne by the buyer.

      Customers who need to issue additional tickets should inform customer service in advance of the remarks. The above quotation does not include tax, and the bulk purchase price is negotiable. Online orders require confirmation of receipt before invoicing can be issued. We kindly ask for the understanding and support of our customers and friends.

      Regarding the new advertising law, Kelsen expressed support, and our store has made adjustments and improvements to the product content, gradually investigating and improving the true information. Our store hereby solemnly declares that all the wording and functional statements on our pages are invalid and will not be used as a reason for compensation. We hope that consumers can understand and also ask anti-counterfeiting personnel to show mercy.

      Delivery gifts will be randomly distributed by our store and will not be redeemed. The final interpretation rights belong to our store

    AfterSalesService :

    Key words:
    • Supply high air volume vortex high-pressure blower