Ankerui Industrial Insulation Monitoring Instrument AIM
Ankerui Industrial Insulation Monitoring Instrument AIM

Ankerui Industrial Insulation Monitoring Instrument AIM

Category:

Electrical Engineering/Electrical Instruments /Electric energy meter

Model:

AIM-T300

Brand:

Acrel

brand:

Acrel

model:

AIM-T300

type:

Electronic energy meter

Processing & Customization:

No

working principle:

electronic type

Power nature:

DC meter

phase number:

three-phase

structural form:

monolithic

wiring method:

Direct access

manufacturer:

Acrel

Retail Price

10,000.00USD


重量

kg

  • Product Description
  • brand

    Acrel

    model

    AIM-T300

    type

    Electronic energy meter

    Processing & Customization

    No

    working principle

    electronic type

    Power nature

    DC meter

    phase number

    three-phase

    structural form

    monolithic

    wiring method

    Direct access

    manufacturer

    Acrel

    Description :

      The low-voltage system of offshore oil platforms is very different from that of onshore power systems. It belongs to the neutral point ungrounded system. In the event of a single-phase grounding fault, the system allows normal operation with the fault for 2 hours to ensure that important electrical equipment at sea will not be immediately shut down. Nowadays, most offshore platforms use insulation monitoring devices to monitor the insulation condition of the system. When there is a fault, an alarm is issued, but it cannot detect which load in the system has an insulation fault. Platform electrical personnel need to cut off the low-voltage load circuits on site one by one for fault diagnosis, which brings great difficulties to the search for grounding faults. When a single-phase grounding fault occurs in the low-voltage busbar, in order to lock the fault point in time and facilitate on-site electrical personnel to timely troubleshoot and solve the grounding fault, and improve the stability of the low-voltage system, an insulation monitoring and fault location system can be used to achieve the location of the insulation fault circuit and phase line.

    Introduction to Industrial Insulation Monitoring DevicesAnkerui AIM-300, AIM-T500, AIM-T500L Insulation Monitoring Instruments

      The Ankerui AIM-T series insulation monitoring instrument is mainly used in industrial IT distribution systems, including AIM-T300, AIM-T500, and AIMT500L products, all of which are suitable for pure AC, pure DC, and AC/DC wet combination systems.

      The AIM-T300 is suitable for AC, DC, and AC/DC hybrid systems below 450V, while the AIM-T500 is suitable for AC, DC, and AC/DC hybrid systems below 800V.

      The AIM-T500L has added one CAN communication interface and insulation fault location function compared to the AIM-T500.

    1、 Product Overview

    Insulation fault location industrial insulation monitoring deviceIt is mainly used to monitor the insulation condition of IT systems (ungrounded systems) to ground, and to promptly alarm when insulation faults occur in the system, reminding electrical maintenance personnel to troubleshoot the faults.

    2、 Technical parameters

    AIM-T300, AIM-T500, AIM-T500L Insulation Monitoring Instruments

    技术参数1.png

    ASG200 Test Signal Generator

    技术参数2.png

    AIL200-12 insulation fault locator

    技术参数3.png

    ACPD series insulation monitoring coupling instrument

    技术参数4.png

    3、 Specification parameters

    规格参数.jpg

    4、 External dimensions

    外形尺寸.jpg

    5、 Product quotation

    产品报价.png

    6、 Application scope

    Insulation fault location industrial insulation monitoring deviceSuitable for industrial fields such as electrolytic aluminum, mines, glass factories, electric furnaces and testing equipment, metallurgical plants, chemical plants, explosive hazardous areas, computer centers, and emergency power supplies in AC and DC ungrounded systems

      The low-voltage power grid system of offshore oil platforms belongs to an independent power grid system. In order to ensure platform production, the low-voltage system of the platform cannot be shut down due to insulation failure of a certain load. Therefore, the 0.4kV low-voltage power system of the platform adopts a neutral point insulation system. The characteristic of a neutral point insulation system is that when a single-phase grounding occurs, the voltage and phase between each phase remain unchanged, and the balance of the three-phase system is not disrupted, so it can continue to operate in a short period of time. However, if operated with faults for a long time, it can cause phase to phase short circuits, or when single-phase arc light is grounded, the system will resonate and cause overvoltage, which will put a lot of pressure on the platform production.

      Nowadays, most oil platforms are equipped with insulation monitoring devices. The original insulation monitoring equipment can only monitor the insulation level of the entire busbar and cannot detect which specific load has insulation faults. Therefore, insulation monitoring and fault location systems can be used to locate insulation fault circuits.

      The hardware architecture of the underground power cable online monitoring system terminal includes low-frequency signal source, voltage and current transformer, signal conditioning circuit, digital/analog acquisition circuit, DSP central processor, CAN bus communication, keyboard input, power supply, clock, display and other modules. During operation, the input terminal of the signal conditioning circuit is a voltage current transformer, which converts the received signal into a signal that can be recognized by the A/D module for conversion from analog signal to digital signal, and then transmits it to the DSP central processor for data processing and operation.

      The function of the current transformer is to monitor the low-frequency current signal of the cable in real time, and a closed-loop Hall type high-precision current transformer with model SCB2 is selected. The range of the current transformer is 0~10mA, the input current range is 0~10mA, the output current range is 0~25mA, the full-scale linearity is ± 0.2%, the full-scale accuracy is ± 0.8%, and the response time is less than 20uS. The function of the voltage transformer is to monitor low-frequency voltage signals in real time. The selected model is a Hall current type voltage transformer, with an input current range of 0~14mA, an output current range of 0~25mA, and a measurement voltage range of 10~500V. The function of the analog/digital conversion module is to convert the collected voltage and current signals into digital signals in real time. The A/D module with model ADS8365 is selected, which has high accuracy and 16 bit parallel data transmission function, and can simultaneously transmit 6 analog signals. Synchronous sampling and conversion. The DSP central processing unit is selected as the TMS320F28335 chip, which supports multiple languages and codes and has good program portability.

      The main program flow of the underground power cable insulation online monitoring system: perform system initialization, enter the frequency measurement program after completing resource allocation, followed by the A/D sampling program to complete the acquisition of low-frequency voltage and current signals of the power cable; After processing the data and calculating the modulus, the insulation resistance of the cable to ground can be obtained. Compared with the standard resistance value, if the measured insulation resistance of the cable is less than the standard value, the system will enter the alarm program to issue a warning, and the cable number and measured insulation resistance value of the insulation resistance fault will be displayed on the operation panel; At the same time, start the CAN bus communication program to transmit the cable number and measured resistance value to the human-computer interaction interface.