Wireless Temperature Monitoring System for Substation
Wireless Temperature Monitoring System for Substation

Wireless Temperature Monitoring System for Substation

Category:

Electrical Engineering/Complete electrical and electrical equipment/Other electrical and electrical equipment

Model:

ACREL

Brand:

Acrel

brand:

Acrel

model:

APF

type:

manufacturer

Processing & Customization:

No

purpose:

Distributed photovoltaic collection

Motor power:

100KW

Overall dimensions:

35mm guide rail

weight:

two

Place of Origin:

Jiangyin, Jiangsu

manufacturer:

Ankerui manufacturer

Retail Price

2,000.00USD


重量

kg

  • Product Description
  • brand

    Acrel

    model

    APF

    type

    manufacturer

    Processing & Customization

    No

    purpose

    Distributed photovoltaic collection

    Motor power

    100KW

    Overall dimensions

    35mm guide rail

    weight

    two

    Place of Origin

    Jiangyin, Jiangsu

    manufacturer

    Ankerui manufacturer

    Description :

      Circuit design and dual power management technology for wireless temperature monitoring system in substations

      The wireless temperature measurement and early warning system of high-voltage substation adopts dual-power management technology to manage the intelligent temperature sensor and the wireless transceiver module respectively, which can reduce the power consumption and improve the service life of the sensor. Due to the small working current of temperature sensor, ultra-low power single-chip microcomputer and peripheral circuit, 3.6V, 3000mA battery is mainly used for power supply in the circuit design process. The large continuous discharge current and large pulse discharge current of the battery can reach 150mA and 300mA respectively. Calculated according to 80% battery utilization rate, Life expectancy can reach more than two years. Through the control of single chip microcomputer to the current do not need to work on the parts of power protection, effectively improve the utilization rate of electricity. In addition, in order to effectively prolong the service life of the wireless temperature measurement early warning system in high-voltage substation, under the premise of meeting the operating frequency of equipment, a smaller working frequency can be selected to reduce the power consumption of the single-chip microcomputer. Moreover, energy consumption should also be emphasized in the design of peripheral circuits and equipment selection.

      Product Introduction

      Function:

      ARTM Pn wireless temperature measurement device: The ARTM Pn wireless temperature measurement device can be installed separately in high-voltage cabinets and low-voltage drawer cabinets. Each device can receive data from 18 sensors, and sensor models can be selected as ATE100, ATE200, or ATE300. The device is equipped with a 485 interface, which can upload the collected temperature data to the monitoring center.

      ARTM8 Temperature Inspection Instrument: The ARTM series temperature inspection and control instrument is suitable for measuring and controlling one or multiple temperatures, mainly used for temperature inspection, measurement and control in thermal power plants, hydropower stations and other occasions. Measure the temperature of Pt100 in 8 channels, and any channel can also be shielded. Each channel temperature measurement corresponds to 2 alarm segments, and the relay output can be set to any alarm direction and value.

      Wireless temperature measurement centralized collection touch screen: The wireless temperature measurement touch screen can be embedded and installed in high-voltage cabinets and low-voltage drawer cabinets. Each device can receive data from 240 sensors and can be optionally used with ATE100, ATE200, and ATE300 sensors. The device is equipped with a 485 interface and an optional Ethernet port, which can upload the collected temperature data to the monitoring center.

      Application scope:

      Suitable for temperature monitoring of cable joints, circuit breaker contacts, knife switch switches, high-voltage cable intermediate heads, dry-type transformers, low-voltage high current equipment, etc. inside high and low voltage switchgear.

      Ordering Example:

      Technical requirements: Passive wireless temperature measurement with 6-point circuit breaker contacts and 3-point busbar in one high-voltage cabinet

      Auxiliary power supply: AC/DC 220V

      Display mode: standalone wireless temperature display

      In summary, the confirmed model is: wireless temperature measurement device: ARTM-P9-300, 1 unit; Wireless temperature sensor: ATE300, 9 pieces

      Ordering Example:

      Technical requirements: Wireless temperature measurement for 6-point circuit breaker contacts and 3-point busbar in 10 high-voltage cabinets

      Wireless sensor requirements: battery powered, wireless

      Display mode: centralized wireless temperature display

      In summary, the confirmed model is: Wireless temperature measurement centralized touch screen: AARTM-7062HT-4 (HI), 1 unit; Wireless temperature sensors: ATE200,90 pieces; Wireless temperature measurement transceiver: ATC200,10

      Ordering Example:

      Technical requirements: Wireless temperature measurement for 6-point circuit breaker contacts and 3-point busbar in 10 high-voltage cabinets

      Wireless sensor requirements: Passive wireless

      Display mode: centralized wireless temperature display

      In summary, the confirmed model is: wireless temperature measurement centralized touch screen: ARTM-7062HT-4 (HI), 1 unit; Wireless temperature sensors: ATE300, 90 pieces; Wireless temperature measurement transceiver: ATC400, 1 unit; Power module: ARTM-KDYA-DG30-24K, 1 unit.

      technical indicators

      Product features

      Overall dimensions

      Product Quotation

      Software low power consumption implementation, when the bus is in a small current state, the magnetic induction coil to obtain less energy, so the entire circuit power is very low, so not only requires low power chip, software design is also particularly important. Low power program design, through the sleep of single chip microcomputer and wireless transceiver and the shutdown of peripheral circuit, make the whole circuit high current is not more than 30ms, the power consumption of wireless transmission is not more than 500ms.

      Wireless Temperature Monitoring System for Substation

    AfterSalesService :

    Key words:
    • Wireless Temperature Monitoring System for Substation