APP energy meter ADW300 forward and reverse energy metering
APP energy meter ADW300 forward and reverse energy metering

APP energy meter ADW300 forward and reverse energy metering

Category:

Instrumentation/Standard measuring instruments/Optical metrology standards

Model:

ADW

Brand:

Acrel

model:

ADW

measurement range:

0-400V

accuracy:

Level 0.5

resolution:

LCD (Liquid Crystal Display)

Processing & Customization:

No

Overall dimensions:

35mm guide rail

Place of Origin:

Jiangyin, Jiangsu

manufacturer:

Acrel

Retail Price

1,000.00USD


重量

kg

  • Product Description
  • model

    ADW

    measurement range

    0-400V

    accuracy

    Level 0.5

    resolution

    LCD (Liquid Crystal Display)

    Processing & Customization

    No

    Overall dimensions

    35mm guide rail

    Place of Origin

    Jiangyin, Jiangsu

    manufacturer

    Acrel

    Description :

       The operation and maintenance of photovoltaic power plants are crucial to their power generation, including photovoltaic modules, inverters, related electrical circuits, step-up transformers, and grid connected cabinets. Data monitoring is a very important part of photovoltaic power plant operation and maintenance. Various data indicators of the photovoltaic power plant can be obtained in real time through the operation and maintenance management system, and the operating status and efficiency of the power plant can be judged through these data indicators. In terms of data monitoring, the following tests need to be conducted on photovoltaic power plants: firstly, real-time monitoring of parameters such as voltage, current, and power of the power plant is required to understand the real-time working status of the photovoltaic power plant. Secondly, it is necessary to monitor the environmental factors such as temperature, humidity, and solar irradiance of the photovoltaic power station to understand the operating environment of the power station. It is necessary to detect and analyze the cumulative power generation of photovoltaic power plants, the operation of components and inverters, etc., in order to take corresponding maintenance measures in a timely manner. GB/T 38946-2020 "Technical Specification for Centralized Operation and Maintenance of Distributed Photovoltaic Power Generation Systems" provides clear requirements for the operation and maintenance of distributed photovoltaic power stations, as well as the functions of centralized operation and maintenance main stations and sub stations

      Introduction

      In the context of dual carbon, the substitution of electricity for enterprise energy consumption will be a long-term trend. Therefore, a large number of new electrical equipment will be added within the enterprise. Improving the energy efficiency level of these equipment will reduce the total electricity consumption and help achieve the dual carbon goal as soon as possible.

      Energy metering instruments that require multiple communication methods, support embedded and rail mounted installation, RS485, Lora, 4G and other data upload modes, and can achieve wiring free and power free construction.

      Electric energy meters are installed at major distribution nodes, key energy consuming equipment, etc. They collect real-time electricity data, monitor the operation of the distribution system, and analyze the electricity data hourly, daily, and monthly. Combined with national and industry standards, they calculate the overall carbon emissions of the enterprise and provide basic data services for carbon neutrality.

      1、 Product Overview

      The ADW300 wireless measuring instrument is mainly used to measure three-phase active energy in low-voltage networks. It has RS485 communication and 470MHz wireless communication functions, making it convenient for users to monitor, collect and manage electricity consumption. It can be flexibly installed in the distribution box to achieve sub item energy measurement, statistics, and analysis for different areas and loads.

      2、 Model Description

      

      3、 Technical parameters

      

      4、 Product Features

      

      

      5、 Application scope

      ADW300-4GWireless metering instruments for power Internet of ThingsThe ADW300 is convenient for users to monitor, collect and manage electricity usage, and can be flexibly installed in distribution boxes. It can be used in online monitoring platforms such as power operation and maintenance, environmental supervision, etc.

      6、 Ordering Example

      Specific model: ADW300W-LR/KCTL Technical requirements: Rated current 3 × 1.5 (6) A (ADW300W), 3 × 20 (100) A (ADW300W) Communication protocol: C: RS485 communication; LR: Lora Auxiliary Power Supply: AC220V

      7、 Application Networking Diagram

      8、 Exterior installation

      Overall dimensions

      wiring method

      ADW300 three-phase four wire

      ADW300 three-phase three wire

      ADW300W three-phase four wire

      Installation Diagram

      On site installation diagram

      9、 Application scenarios

    image.png

      The Acrel1000-DP distributed photovoltaic power monitoring system provides a solution for the operation and maintenance subsystem of distributed photovoltaic power plants, meeting the relevant technical requirements for operation and maintenance substations in GB/T 38946 "Technical Specification for Centralized Operation and Maintenance of Distributed Photovoltaic Power Generation Systems".

      ① Data signal acquisition

      (1) The analog data collected by the operation and maintenance substation includes the following:

      a) What is the active power of each grid connection point in a distributed photovoltaic power generation system? Reactive power? Voltage? electric current? Frequency? Electric energy and other data;

      b) What is the active power of distributed photovoltaic inverters? Reactive power? Voltage? electric current? Power? Temperature and other data;

      c) What is the current of each channel in the combiner box? Summarize output current? Bus voltage and other data;

      d) What is the surrounding environment of a distributed photovoltaic power generation system, including ambient temperature? Irradiance? Data such as battery panel temperature;

      e) The sub station should establish data storage, and the storage time should not be less than 7 days?

    AfterSalesService :

    Key words:
    • APP energy meter