Explosion proof LZ metal tube float flowmeter LZ-50 intelligent metal tube float flowmeter
Category:
Instrumentation/Flow meter/flowmeter
Model:
LZ-50
Brand:
Jiangsu Fenghui Instrument Co., Ltd
Retail Price
1,800.00USD
重量
kg
- Product Description
-
Description :
1、 Product Description:
This product adopts the principle of variable area measurement and is suitable for measuring liquids and gases. All metal structure, including indicator type, electric remote transmission type, corrosion-resistant type, high-voltage type, jacket type, and explosion-proof type.
2、 Technical parameters:
Several power supply methods are available: DC24V, AC220V, and battery power supply.
Range ratio: 10:1 (special type 20:1)
Accuracy: Level 1.5, Level 1.0
Work pressure: DN15~DN50 PN4.0MPa
DN80~DN100 PN1.6MPa
Jacket pressure rating: 1.6MPa
Medium temperature: Standard type: -80 ℃~+220 ℃ High temperature type: 400 ℃; PTFE lining type ≤ 85 ℃
Environmental temperature: pointer type: -40 ℃~+120 ℃, electric remote transmission type: -30 ℃~+65 ℃
Medium viscosity: DN15: ≤ 5mPa. s (H15.1~H15.3): ≤ 30mPa. s (H15.4~H15.9)
DN25:≤250mPa.s DN50~DN150:≤300mPa.s
Output: Standard signal: Two wire system 4.20mA Pulse signal: Maximum interval of 50ms
Power supply: Standard type: DC24V (DC10.8V~DC36V) AC type: AC220V (AC85V~AC265V);
Connection method: Standard type: DIN2501 Flange special type: User provided flange Standard thread connection type: DIN11851 or user specified
Electrical interface: M20 × 1.5, 1/2 "NPT
Protection level: IP65

3、 Installation:
1. When used for gas measurement, it should be ensured that the pipeline pressure is not less than 5 times the pressure loss of the flowmeter to ensure stable operation of the float;
2. In order to avoid deformation of the flow meter caused by the pipeline, the flange of the process pipeline must be coaxial and parallel to the flange of the flow meter. The pipeline support should be used to avoid pipeline vibration and reduce the axial load of the flow meter. The control valve in the measurement system should be installed downstream of the flow meter:
3. When measuring gas, if the gas is directly discharged into the atmosphere at the outlet of the flowmeter, a valve should be installed at the outlet of the instrument, otherwise a pressure drop will occur at the float, causing data distortion.
4. When installing instruments with PTFE lining, do not tighten the flange nuts asymmetrically at will to avoid deformation of the PTEF lining;
5. Instruments with LCD displays should avoid direct sunlight on the display as much as possible to avoid reducing the lifespan of the LCD; Instruments powered by lithium batteries should avoid direct sunlight and high temperature environments (≥ 65 ℃) as much as possible to avoid reducing the capacity and lifespan of the lithium battery.

AfterSalesService :