Sales of DN80 electromagnetic flowmeter DN80 electromagnetic flowmeter direct sales
Category:
Instrumentation/Flow meter/electromagnetic flowmeter
Model:
LDE-80
Brand:
Jiangsu Fenghui Instrument Co., Ltd
Retail Price
1,800.00USD
重量
kg
- Product Description
-
Description :
This product is mainly used to measure the volumetric flow rate of conductive liquids and slurries in closed pipelines. Including highly corrosive liquids such as acids, alkalis, salts, etc. The measurement accuracy is not affected by the type of measured medium and its physical parameters such as temperature, viscosity, density, pressure, etc.
1、 Technical parameters:
Caliber: DN10-DN2000 (mm) Special customizable
Nominal pressure: 0.6-4.0MPa (differentiated by caliber, special high pressure can be customized)
Electrode materials: 316L stainless steel, Hastelloy C, Hastelloy B, titanium, tantalum, platinum iridium electrode
Lining materials: polytetrafluoroethylene (PTFE), perfluoroethylene propylene (FEP), chloroprene rubber (Ne), polyurethane rubber (PU)
Medium temperature: -40~180 ℃ (limited by the temperature resistance characteristics of the lining material, as follows:
Neoprene rubber lining: -40~+80 ℃ Polyurethane rubber lining: -10~+60 ℃
PTFE lining: -30~+120 ℃, PTFE lining: -30~+180 ℃
Shell material carbon steel (customizable stainless steel shell)
Protection levels IP65, IP67, IP68
Working power supply 220VAC, 24VDC
Current output 4~20mA

2、 Technical features:
1. Suitable for liquid flow detection with conductivity greater than 5 μ s/cm. Changes in conductivity do not affect performance changes
2. Electromagnetic flow meters have long-term high measurement accuracy and are actually not affected by fluid physical properties
3. Easy to put into operation, the flowmeter is automatically set within the range of 0-10m/s, without the need to change the measurement range
4. All components in contact with the tested medium have good corrosion resistance and wear resistance, with a wide range of applications
5. There are no movable parts or flow blocking components in the pipeline, and there is almost no additional pressure loss during measurement
6. The measurement results are independent of physical parameters such as flow velocity distribution, fluid pressure, temperature, density, viscosity, etc
3、 Installation:
1. Selection of installation location:
The installation position must ensure that the pipeline is always filled with the measured liquid.
Choose a location with low liquid flow pulses, which should be away from local resistance components such as pumps, valves, and elbows.
When measuring biphasic (solid, liquid, gas, liquid) liquids, a location that is not prone to phase separation should be selected.
The inner diameter or circumference of the tested pipeline should be easy to measure, and the ellipticity should be small.
2. Length of straight pipe section of sewage flowmeter:
The length of the straight pipe section on the upstream side of the sensor installation pipeline should be greater than or equal to 10D, and the downstream side should not be less than 5D.

AfterSalesService :
Key words:- DN80 electromagnetic flowmeter