Supply LDG electromagnetic flowmeter LDG-125 electromagnetic flowmeter direct sales
Supply LDG electromagnetic flowmeter LDG-125 electromagnetic flowmeter direct sales

Supply LDG electromagnetic flowmeter LDG-125 electromagnetic flowmeter direct sales

Category:

Instrumentation/Flow meter/flowmeter

Model:

LDG-125

Brand:

Jiangsu Fenghui Instrument Co., Ltd

Retail Price

1,850.00USD


重量

kg

  • Product Description
  • Description :

      This product is used for flow measurement of various conductive liquids in industrial engineering, such as corrosive media such as acids, alkalis, salts, etc; Various flammable and explosive media; The measurement of various slurry flow rates in wastewater treatment, chemical, food, pharmaceutical and other industries has formed a unique application field.

      1、 Structure

      The product structure mainly consists of magnetic circuit system, measuring conduit, electrode, shell, lining, and converter.

      2、 Performance indicators

      Flow velocity measurement range: (0.05-10) m/s

      Power consumption:<15VA

      Protection level: IP68

      Connection method: flange connection

      Electrode materials: molybdenum containing stainless steel OCr18Ni12Mo2Ti, Hastelloy B, Hastelloy C, titanium Ti, tantalum, etc

      Measuring pipeline diameter: DN (32-6000) mm

      Instrument accuracy: Level 1.0

      Work pressure: ≤ 1.6MPa

      Medium temperature: 0-80 ℃

      3. Installation

      1. Horizontal and vertical installation

      Sensors can be installed horizontally and vertically, but it should be ensured to avoid the influence of sediment and bubbles on the measuring electrode, and the electrode axis should be kept horizontal. When installed vertically, the fluid should flow from bottom to top. The sensor cannot be installed at the highest position of the pipeline, as this position is prone to the accumulation of air bubbles.

      2. Ensure full pipe installation

      Ensure that the flow sensor is filled with the measured fluid in the pipeline during measurement and that there is no non full pipe state. If the pipeline is not full or the outlet is empty, the sensor should be installed on a siphon tube.

      3. Installation between bends, valves, and pumps

      To ensure the stability of the measurement, a straight pipe section should be installed before and after the sensor, with its length given. If it cannot be achieved, a current stabilizer should be used or the cross-sectional area of the measurement point should be reduced.

      4. Sensors cannot be installed at the inlet of the pump

      To avoid negative pressure, the sensor should not be installed at the inlet of the pump, but at the outlet of the pump.