Explosion proof LDG electromagnetic flowmeter LDG-65 explosion-proof electromagnetic flowmeter
Explosion proof LDG electromagnetic flowmeter LDG-65 explosion-proof electromagnetic flowmeter

Explosion proof LDG electromagnetic flowmeter LDG-65 explosion-proof electromagnetic flowmeter

Category:

Instrumentation/Flow meter/electromagnetic flowmeter

Model:

LDG-65

Brand:

Jiangsu Fenghui Instrument Co., Ltd

Retail Price

1,800.00USD


重量

kg

  • Product Description
  • Description :

      This product can not only meet on-site display requirements, but also output 4-20mA current signals for recording, adjustment, and control. It has been widely used in industrial technology and management departments such as chemical, environmental protection, metallurgy, medicine, papermaking, and water supply and drainage.

      1、 Performance characteristics:

      The instrument structure is simple, reliable, without moving parts, and has a long working life.

      No flow blocking components, no pressure loss or fluid blockage.

      No mechanical inertia, fast response, good stability, can be applied to automatic detection, adjustment, and program control systems.

      The measurement accuracy is not affected by the type of measured medium and its physical parameters such as temperature, viscosity, density, pressure, etc.

      Different combinations of PTFE or rubber lining materials and electrode materials such as Hc, Hb, 316L, Ti can adapt to the needs of different media.

      There are various flow meter models available, including pipeline type and plug-in type.

      Using EEPROM memory, the storage of measurement and operation data ensures safety and reliability.

      It has two types: integrated and separated.

      High definition LCD backlit display.

      2、 Performance indicators:

      Flow velocity measurement range: (0.05-10) m/s

      Power consumption:<15VA

      Protection level: IP68

      Connection method: flange connection

      Electrode materials: molybdenum containing stainless steel OCr18Ni12Mo2Ti, Hastelloy B, Hastelloy C, titanium Ti, tantalum, etc

      Measuring pipeline diameter: DN (32-6000) mm

      Instrument accuracy: Level 1.0

      Work pressure: ≤ 1.6MPa

      Medium temperature: 0-80 ℃

      3、 Installation:

      1. Horizontal and vertical installation

      Sensors can be installed horizontally and vertically, but it should be ensured to avoid the influence of sediment and bubbles on the measuring electrode, and the electrode axis should be kept horizontal. When installed vertically, the fluid should flow from bottom to top. The sensor cannot be installed at the highest position of the pipeline, as this position is prone to the accumulation of air bubbles.

      2. Ensure full pipe installation

      Ensure that the flow sensor is filled with the measured fluid in the pipeline during measurement and that there is no non full pipe state. If the pipeline is not full or the outlet is empty, the sensor should be installed on a siphon tube.

      3. Installation between bends, valves, and pumps

      To ensure the stability of the measurement, a straight pipe section should be installed in front and behind the sensor, with its length given in the following figure. If it cannot be achieved, a current stabilizer should be used or the cross-sectional area of the measurement point should be reduced.

      4. Sensors cannot be installed at the inlet of the pump

      To avoid negative pressure, the sensor should not be installed at the inlet of the pump, but at the outlet of the pump.

      5. Inlet and outlet straight pipe sections of the sensor

      An ideal installation location should be chosen with sufficient straight pipe sections before and after the measurement point. The inlet straight pipe section should be ≥ 5D, and the outlet straight pipe section should be ≥ 3D (D is the nominal diameter of the sensor). The inserted inlet straight pipe section should be ≥ 20D, and the outlet straight pipe section should be ≥ 7D (D is the nominal diameter of the sensor).

    AfterSalesService :