  • Product Description
  • Description :

      The measurement accuracy of this product is not affected by the type of measured medium and its physical parameters such as temperature, viscosity, density, pressure, etc. Different combinations of PTFE or rubber lining materials and electrode materials such as Hc, Hb, 316L, Ti can adapt to the needs of different media.

      1、 Product features:

      1. Suitable for volumetric flow measurement of conductive fluids with conductivity greater than 5 ц s/cm;

      2. There are no active or obstructed components inside the measuring tube, and the pressure loss is small;

      3. Lining and electrodes with different materials have good anti-corrosion performance;

      4. Not affected by medium, density, viscosity, temperature, pressure, and conductivity;

      5. Low frequency rectangular wave excitation, less susceptible to interference, stable and reliable;

      6. The converter has low energy consumption, simple and convenient installation, and users do not need to debug.

      2、 Technical parameters:

      Accuracy level: ± 0.5%, ± 1%

      Lining materials: polyurethane, chloroprene rubber, polytetrafluoroethylene, etc

      Electrode materials: stainless steel, Hastelloy, titanium, platinum iridium alloy, etc

      Connection methods: flange clamping, flange connection, etc

      Medium temperature: 0 ℃~70 ℃, 0 ℃~130 ℃ (0 ℃~180 ℃)

      Nominal pressure: 1.0Mpa~32 Mpa

      Protection level: IP65, IP68

      Explosion proof mark: ExibBT4

      Working voltage: 220VAC, 24VDC

      3、 Installation:

      1. Try to avoid ferromagnetic objects and equipment with strong electromagnetic fields (such as large motors, transformers, etc.) to prevent the magnetic field from affecting the working magnetic field and flow signal of the sensor.

      2. It should be installed in a dry and ventilated place as much as possible, and should not be installed in damp or water prone areas.

      3. Avoid direct sunlight and rain as much as possible, and avoid environments with temperatures above 60 ℃ and relative humidity above 95%.

      4. Choose a place that is easy to maintain and has convenient activities.

      5. The flowmeter should be installed at the rear end of the water pump and must not be installed on the suction side; The valve should be installed on the downstream side of the flow.