Supply LUGB-250 vortex flowmeter
Category:
Instrumentation/Flow meter/Vortex Flowmeter
Model:
LUGB-250
Brand:
Jiangsu Fenghui Instrument Co., Ltd
Retail Price
2,900.00USD
重量
kg
- Product Description
-
Description :
Supply LUGB-250 vortex flowmeter
This product is widely used for measuring fluids in industries such as petroleum, chemical, metallurgical, papermaking, power generation, and water conservancy. The flowmeter has no movable parts, strong reliability, high accuracy, and long service life. It can accurately measure the instantaneous flow rate and cumulative flow rate of fluids over a wide flow range.
1、 Characteristics:
1. Steam, gas, and liquid can all be measured;
2. Low pressure loss;
3. No compensation is required when measuring volumetric flow rate;
4. Components with simple structure and no motion wear and tear;
5. High precision, high reliability, no need for on-site debugging;
6. Easy to install and maintain;
7. It can transmit traffic signals over long distances, connect with computers, and achieve integrated management.

Supply LUGB-250 vortex flowmeter
2、 Main technical parameters:
1. Measurement media: liquid, general gas, natural gas, steam (saturated steam and superheated steam);
2. Possible measurement range: Reynolds number ranging from 5 × 103 to 7 × 106
3. Normal measurement range: Reynolds number ranging from 2 × 104 to 7 × 106
4. Measurement flow rate range: liquid 0.5-7m/s, gas 4-35mm/s, steam 7-70m/s
5. Temperature of the tested fluid: -40 ℃ to+300 ℃
6. Tested fluid pressure: 1.6, 4, 25MPa
7. Accuracy: Level 1, Level 1.5, Level 0.5 (Level 0.5 can only be achieved through non-linear adjustment);
8. Repeatability: 0.2% of the indicated value;
9. Table body material: ICr18Ni9Ti;
10. Pressure loss: △=1.2 × r × V2 × 10-6. In the equation: △ P - pressure loss r - measured fluid density (Kg/m3) v - average flow velocity inside the pipe (m/s)
11. Environmental temperature: -20 ℃~+55 ℃ (special requirements for ordering instructions)
12. Environmental humidity: ≤ 90% RH
13. Atmospheric pressure: 86-106KPa
14. External power supply: 3.6-224VDC
15. Internal power supply: 3-4.5VVDDC
3、 Selection:
1. Before selecting, the type and flow rate value of the measured medium (which can be an estimated value) should be determined first, and then the specifications of the vortex flowmeter should be selected according to the flow range corresponding to different media measured by the vortex flowmeter in the table.
2. The flow rate of the measured medium in the pipeline must be within the flow range of the flowmeter, otherwise it cannot be used and is located at 1/2 to 2/3 of the flow range of the flowmeter.
3. If the actual diameter of the pipeline is larger or smaller than the selected diameter of the flow meter, a contraction tube or expansion tube should be used to reduce the diameter to ensure the correct use of the flow meter.
4. Select the vortex signal output method based on the purpose of the vortex flowmeter.

AfterSalesService :