Cast steel LC-40 elliptical gear flowmeter
Cast steel LC-40 elliptical gear flowmeter

Cast steel LC-40 elliptical gear flowmeter

Category:

Instrumentation/Flow meter/flowmeter

Model:

LC-40

Brand:

Jiangsu Fenghui Instrument Co., Ltd

Retail Price

980.00USD


重量

kg

  • Product Description
  • Description :

      Cast steel LC-40 elliptical gear flowmeter

      This product is a volumetric measuring instrument used for continuous or intermittent measurement and control of liquid flow in pipelines. It has many advantages such as a large range, high accuracy, low pressure loss, strong viscosity adaptability, ability to measure high-temperature and high viscosity liquids, convenient calibration, and installation suggestions. Suitable for flow measurement in departments such as petroleum, chemical, synthetic fiber, transportation, commerce, food, medicine and health.

      1、 Characteristics:

      High measurement accuracy, wide flow range, and good repeatability

      All parts are precision machined on the surface, with no casting surface, and the surface is smooth and beautiful.

      Adopting design, it can be disassembled and reassembled on site without the need for professional personnel, and the original measurement accuracy will not be changed after reassembly.

      Adopting waterproof design, it is particularly suitable for measuring media with high viscosity, and is insensitive to changes in the viscosity of the measured liquid

      On site display can show cumulative flow, instantaneous flow, single flow, etc.

      Easy to install, there is no need for straight pipe sections before and after the flowmeter. Even if the flowmeter is close to valves, bends, reducers, or expanders, there is no need to install straight pipe sections.

      In order to prevent the gears of the flowmeter from getting stuck by impurities, a filter must be installed upstream of the flowmeter.

      Cast steel LC-40 elliptical gear flowmeter

      2、 Technical parameters:

      1. High measurement accuracy: 0.2 and 0.5 levels.

      2. Temperature of the tested medium: -10 ℃~+60 ℃ 100~280 ℃

      3. Power supply (required for output signal): DC24V; DC12V

      4. Output signal (only one type of output signal can be selected):

      a) No output signal

      b) 4~20mA output

      c) Pulse output

      d) RS485 communication

      5. The mechanism is simple, sturdy, and reliable in operation.

      6. Especially suitable for measuring media with high viscosity, and insensitive to changes in the viscosity of the measured liquid.

      7. Easy to install. There is no need for straight pipe sections before and after the flowmeter, even if the flowmeter is close to valves, bends, reducers, or expanders, there is no need to install straight pipe sections.

      3、 Installation and use:

      1. A filter should be installed in front of the flowmeter, and the arrows on both casings should point in the same direction as the flow.

      2. When the measured liquid contains gas, a gas separator should be installed in front of the flowmeter.

      3. Regardless of whether the pipeline is installed vertically or horizontally, the elliptical gear shaft in the flowmeter is installed in a horizontal position. The dial should be perpendicular to the ground.

      4. If it is difficult to see the reading clearly when the flowmeter is installed correctly, the counter can be turned 180 ° or 90 °, both of which are acceptable.

      5. Before installing the new flowmeter, use a bamboo stick to push the gear several times from the outlet. If it doesn't move, you can soak it in gasoline (to avoid sediment accumulation after factory calibration).

      6. The throttle valve should be installed at the inlet of the flowmeter, and the switch valve should be installed at the outlet. When opening and closing each valve, it should be started slowly and not quickly opened or closed.

      7. It is strictly prohibited to use sweeping steam to pass through the flowmeter.

      8. In continuous use departments, flow meters must be equipped with bypass pipelines.

      9. Before installing the flowmeter, the pipeline must be flushed. During flushing, a straight pipe section (replacing the position of the elliptical flowmeter) should be used to prevent welding slag, debris, etc. from entering the flowmeter.

      10. It is strictly prohibited to use water to calibrate flow meters made of cast iron material.