LDG-50 carbon steel electromagnetic flowmeter
LDG-50 carbon steel electromagnetic flowmeter

LDG-50 carbon steel electromagnetic flowmeter

Category:

Instrumentation/Flow meter/electromagnetic flowmeter

Model:

LDG-50

Brand:

Jiangsu Fenghui Instrument Co., Ltd

Retail Price

1,600.00USD


重量

kg

  • Product Description
  • Description :

      LDG-50 carbon steel electromagnetic flowmeter

      This product is an electromagnetic induction flowmeter with a nominal diameter range of 10 to 3000. It is a series of electromagnetic flowmeter products that integrate intelligence, small and lightweight integration, multifunctionality, high precision, and high reliability.

      1、 Technical performance indicators:

      Flow velocity measurement range: (0.05-10) m/s

      Power consumption:<15VA

      Protection level: IP68

      Connection method: flange connection

      Electrode materials: molybdenum containing stainless steel OCr18Ni12Mo2Ti, Hastelloy B, Hastelloy C, titanium Ti, tantalum, etc

      Measuring pipeline diameter: DN (32-6000) mm

      Instrument accuracy: Level 1.0

      Work pressure: ≤ 1.6MPa

      Medium temperature: 0-80 ℃

      LDG-50 carbon steel electromagnetic flowmeter

      2、 Functional features:

      1. Adopting programmable low-frequency rectangular excitation waves with good stability;

      2. Adopting a 16 bit embedded microprocessor, it has fast computing speed and high accuracy;

      3. Adopting full digital processing, it has strong anti-interference ability, stable performance, and a measurement range of up to 150:1

      4. Adopting high-definition LCD backlight LCD display;

      5. It has bidirectional flow measurement and bidirectional total accumulation functions, and bidirectional output functions for current and frequency;

      6. Optional M-bus and HART protocols;

      7. Equipped with self checking and self diagnostic functions;

      8. Widely used in industrial technology and management departments such as chemical industry, environmental protection, metallurgy, medicine, papermaking, water supply and drainage.

      3、 Installation:

      1. Determine the installation location in order to make a reasonable choice between integrated or split electromagnetic flow meters;

      2. Clearly measure the diameter of the measured pipeline;

      3. Clarify whether the medium is conductive; (Conductivity>5 μ S/cm)

      4. Clearly define their work pressure, working temperature, and working flow rate;

      5. Clearly select a lining and electrode material with reasonable chemical properties as the medium.

    AfterSalesService :

    Key words:
    • LDG electromagnetic flowmeter