DN250 LCD display electromagnetic flowmeter
Category:
Instrumentation/Flow meter/electromagnetic flowmeter
Model:
LDG-250
Brand:
Jiangsu Fenghui Instrument Co., Ltd
Retail Price
2,600.00USD
重量
kg
- Product Description
-
Description :
DN250 LCD display electromagnetic flowmeter
The main components of this product are: measuring tube, electrode, excitation coil, iron core, and magnetic yoke housing. It is mainly used to measure the volumetric flow rate of conductive liquids and slurries in closed pipelines. The sensor is installed on the measuring pipeline, and the converter can be installed within 30 meters or 100 meters of the sensor, connected by a shielded cable.
1、 Technical parameters:
1. Provide display interfaces in both Chinese and English;
2. It can directly display the instantaneous flow rate, cumulative flow rate, percentage flow rate, and flow velocity in both forward and reverse directions according to the engineering unit;
3. There are 6 types of flow units to choose from (L/m, L/h, m3/m, m3/h, GPM, GPH);
4. 4~20mADC load 0~750, scale flow rate (upper limit of range) can be set arbitrarily;
5. By setting the pulse coefficient, each pulse can represent a certain volume flow rate, or output a 0-2kHz frequency signal proportional to the flow rate;
6. Provide traffic upper and lower limit reporting function;
7. RS485 interface, bidirectional communication. The working parameters of the flowmeter can be set and modified through the upper computer;
8. When the fluid is stationary, the zero point of the flowmeter can be automatically calibrated through the buttons on the panel;
9. Damping adjustment can be set within a range of 1 to 99 seconds;
10. Power supply voltage: 220VAC/24VDC type;
11. Environmental temperature: -20~60 ℃;
12. Protection level: IP65;
13. Explosion proof grade: ExdibIIBT4.

DN250 LCD display electromagnetic flowmeter
2、 Characteristics:
1. Measurement is not affected by changes in fluid density, viscosity, temperature, pressure, and conductivity;
2. There are no obstructing flow components or pressure loss inside the measuring tube, and the requirements for straight pipe sections are relatively low;
3. Series nominal diameter DN15~DN3000. There are multiple options for sensor lining and electrode materials;
4. The converter adopts a novel excitation method, with low power consumption, stable zero point, and high accuracy. The flow range can reach 1500:1;
5. The converter can be integrated or separated from the sensor;
6. The converter adopts a 16 bit high-performance microprocessor, 2x16 LCD display, convenient parameter setting, and reliable programming;
7. The sewage flowmeter is a bidirectional measurement system, equipped with three integrators: forward total, reverse total, and differential total; Can display. Zhuang, reverse flow, and have multiple outputs: current, pulse, digital communication HART。

DN250 LCD display electromagnetic flowmeter
3、 Selection and installation:
As an industrial flow meter, when designing for users, please carefully check the measured medium and process parameters to ensure correct selection:
1. Determination of applicable traffic range. The selection of instrument diameter is determined based on the flow range. For electromagnetic flow meters, they are generally selected in situations where the flow signal is strong and the instrument can work stably for a long time. We suggest that you choose your instrument caliber based on the flow rate flow comparison table (see table below) and refer to the actual operating conditions. We recommend a flow rate range of 1-3m/s, which is beneficial for the instrument to be in a suitable state.
2. Selection of lining and electrodes. In addition to determining the diameter and flow range, electromagnetic flowmeters also need to choose relevant conditions such as sensor lining and matching electrodes to improve their economic applicability. The design unit can choose different linings, electrodes, etc. according to the different media of different users
3. Pressure and usage situation. In addition to determining the above conditions, the electromagnetic flowmeter should also improve the selection of operating pressure, installation form, shell protection level, explosion-proof requirements, output configuration, and other usage conditions and conditions. The integrated type is suitable for indoor environments with good performance, while the split type is suitable for situations where the sensor is used in harsh environments, with large pipeline vibrations and high temperature of the measured medium. Please choose according to the instrument model markings.