LC-25 elliptical gear flowmeter with pointer
LC-25 elliptical gear flowmeter with pointer

LC-25 elliptical gear flowmeter with pointer

Category:

Instrumentation/Flow meter/Gear flow meter

Model:

LC-25

Brand:

Jiangsu Fenghui Instrument Co., Ltd

Retail Price

950.00USD


重量

kg

  • Product Description
  • Description :

      LC-25 elliptical gear flowmeter with pointer

      It is a volumetric measuring instrument used for continuous or intermittent measurement and control of liquid flow in pipelines. Suitable for flow measurement in departments such as petroleum, chemical, synthetic fiber, transportation, commerce, food, medicine and health.

      1、 Technical parameters:

      Allowable errors: ± 0.1%, ± 0.2%, ± 0.5%

      Nominal diameter DN (mm): 4-300

      Nominal pressure PN (M.Pa): cast iron (A), stainless steel (P) 1.0, 1.6, 2.5, 4.0, 6.3, cast steel (E) 2.5, 4.0, 6.3, 9.6

      Temperature of the tested liquid: Low temperature type: -40~+60 ℃, normal temperature type: -10 ℃~+80 ℃, medium temperature type: -10 ℃~+200 ℃, high temperature type: -10 ℃~+300 ℃

      Measured liquid viscosity (mPa. s): 0.3-50000

      Pipeline connection: GB/T9118-2000 (Chinese standard flange); NIST (American Standard Flange), BSPT (British Standard Pipe Thread): NPT (American Push Pull Pipe Thread);

      On site display: 99999999 L (cumulative flow), 9999999.9 L (single flow), 9999999.9 L (instantaneous flow)

      Output signal: pulse signal, 4-20mA, 1-5V, 4-20mA+HART protocol MODBUS, Supports RS232 and RS485 communication (optional)

      Explosion proof grade: EXiaIIBT5EXiaIICT5

      Protection level: IP65

      LC-25 elliptical gear flowmeter with pointer

      2、 Characteristics:

      1. Flow measurement is independent of the flow state of the fluid and has a wide measurement range.

      2. The higher the viscosity of the medium, the smaller the amount of leakage from the gear and measuring space gap. Therefore, the larger the viscosity of the measured medium, the smaller the leakage error, and the more advantageous it is for measurement.

      3. The elliptical gear flowmeter has high measurement accuracy and is suitable for measuring the flow rate of high viscosity media.

      4. There is no need for straight pipe sections before and after the flowmeter, even if the flowmeter is close to valves, bends, reducers, or expanders, there is no need to install straight pipe sections.

      5. High measurement accuracy: 0.2 and 0.5 levels.

      6. It can measure various oils and non corrosive liquid media for cast iron.

      3、 Installation:

      1. A filter should be installed in front of the flowmeter, and the arrows on both casings should point in the same direction as the flow.

      2. When the measured liquid contains gas, a gas separator should be installed in front of the flowmeter.

      3. Regardless of whether the pipeline is installed vertically or horizontally, the elliptical gear shaft in the flowmeter is installed in a horizontal position.

      4. If it is difficult to see the reading clearly when the flowmeter is installed correctly, the counter can be turned 180 ° or 90 °, both of which are acceptable.

      5. Before installing the new flowmeter, use a bamboo stick to push the gear several times from the outlet. If it doesn't move, you can soak it in gasoline (to avoid sediment accumulation after factory calibration).

    AfterSalesService :

    Key words:
    • LC elliptical gear flowmeter