LDG domestic electromagnetic flowmeter
Category:
Instrumentation/Flow meter/electromagnetic flowmeter
Model:
LDG
Brand:
Jiangsu Fenghui Instrument Co., Ltd
Retail Price
1,700.00USD
重量
kg
- Product Description
-
Description :
LDG domestic electromagnetic flowmeter
1. Overview:
This product can measure the flow rate of dirty media, corrosive media, and suspended liquid-solid two-phase flow. This is because there are no flow obstructing components inside the instrument measuring tube, and only the inner lining and electrodes of the measuring tube are in contact with the measured fluid. The material can be selected according to the properties of the measured fluid. For example, using polytetrafluoroethylene or polytetrafluoroethylene as lining can measure various corrosive media such as acids, alkalis, salts, etc; The use of wear-resistant rubber as an inner lining is particularly suitable for measuring liquid-solid two-phase flows such as slurry and cement slurry with solid particles and high wear, as well as various suspended liquids such as fibrous liquids and pulp.
2、 Characteristics:
1. The range of electromagnetic flowmeter is wide.
2. In addition to measuring the volumetric flow rate of general conductive liquids, electromagnetic flow meters can also be used to measure strongly corrosive liquids such as strong acids and alkalis, as well as slurries, slurries, and pulp.
3. A bidirectional measurement system that can measure both forward and reverse flow rates.
4. The measurement results of electromagnetic flowmeter are independent of physical parameters such as pressure, temperature, density, viscosity, conductivity, and are not affected by the environment.
5. Electromagnetic flowmeter has reliable performance, high accuracy, low power consumption, stable zero point, and convenient parameter setting. Click on the Chinese display LCD to show accumulated flow, instantaneous flow, flow rate, flow percentage, etc.

LDG domestic electromagnetic flowmeter
3、 Technical parameters:
Nominal diameter (mm) (special specifications can be customized)
Pipeline type PTFE lining: DN10~DN600
Pipeline rubber lining: DN40~DN2200
Flow direction: positive, negative, net flow
Range ratio: 150:1
Repetitive error: ± 0.1% of the measured value
Accuracy level: Pipeline type: 0.5 level, 1.0 level
Temperature of the tested medium: ordinary rubber lining: -20 to+60 ℃; High temperature rubber lining: -20 to+90 ℃
PTFE lining: -30 to+100 ℃; High temperature PTFE lining: -20 to+180 ℃
Rated working pressure: (high pressure can be customized) DN10- DN150: ≤ 1.6MPa; DN200-DN350:≤1.0MPa
DN400-DN1000:≤0.6MPa; DN450-DN2200:≤0.25MPa
Flow velocity range: 0.1-15m/s
Conductivity range: The conductivity of the measured fluid is ≥ 5 μ s/cm
Signal output: 4-20mA (load resistance 0-750 Ω), pulse/frequency, control level
Communication output: RS485, MODBUS protocol, HART protocol
Power supply: AC220V or DC24V
Requirement for straight pipe length: upstream ≥ 5DN, downstream ≥ 2DN

LDG domestic electromagnetic flowmeter
4、 Installation precautions:
Avoid lightning strikes
Ensure ventilation and dryness, avoid excessive temperature, humidity, and corrosive gases
Electromagnetic flow meters installed outdoors should have shading and rainproof measures, and avoid direct sunlight exposure
5、 Daily maintenance:
Regularly check whether the electromagnetic flowmeter converter is immersed in water, damp, or corroded
Regularly clean the electrodes and measuring tubes, and do not damage the electrodes and lining during cleaning
Regularly check whether the aging and contact degree of the connecting cables are intact

AfterSalesService :
Key words:- LDG domestic electromagnetic flowmeter