  • Product Description
  • Description :

      Domestic electromagnetic flowmeter manufacturer, domestic electromagnetic flowmeter

      This product consists of two parts: sensors and converters. It works based on Faraday's law of electromagnetic induction and is used to measure the volumetric flow rate of conductive liquids with a conductivity greater than 5 μ S/cm. It is an inductive instrument for measuring the volumetric flow rate of conductive media.

      1、 Characteristics:

      1. Three electrode structure safety grounding

      2. Electrode materials: Hastelloy C alloy, titanium, tantalum

      3. PTFE lining resistant to strong acids and alkalis

      4. Stainless steel casing extends lifespan

      5. Density conversion function, easy to calculate mass

      Domestic electromagnetic flowmeter manufacturer, domestic electromagnetic flowmeter

      2、 Technical parameters:

      Nominal diameter (mm) (special specifications can be customized)

      Pipeline type PTFE lining: DN10~DN600

      Pipeline rubber lining: DN40~DN2200

      Flow direction: positive, negative, net flow

      Range ratio: 150:1

      Repetitive error: ± 0.1% of the measured value

      Accuracy level: Pipeline type: 0.5 level, 1.0 level

      Temperature of the tested medium: ordinary rubber lining: -20 to+60 ℃; High temperature rubber lining: -20 to+90 ℃

      PTFE lining: -30 to+100 ℃; High temperature PTFE lining: -20 to+180 ℃

      Rated working pressure: (high pressure can be customized) DN10- DN150: ≤ 1.6MPa; DN200-DN350:≤1.0MPa

      DN400-DN1000:≤0.6MPa; DN450-DN2200:≤0.25MPa

      Flow velocity range: 0.1-15m/s

      Conductivity range: The conductivity of the measured fluid is ≥ 5 μ s/cm

      Signal output: 4-20mA (load resistance 0-750 Ω), pulse/frequency, control level

      Communication output: RS485, MODBUS protocol, HART protocol

      Power supply: AC220V or DC24V

      Requirement for straight pipe length: upstream ≥ 5DN, downstream ≥ 2DN

      3、 Installation:

      1. Requirements for the external environment

      a、 Flow meters should be avoided from being installed in places with large temperature changes or high temperature radiation from equipment. If installation is necessary, insulation and ventilation measures must be taken.

      b、 The flowmeter should be installed indoors. If it must be installed outdoors, it should be protected from rainwater, waterlogging, and direct sunlight. Moisture and sun protection measures should be taken.

      c、 Flow meters should be avoided from being installed in environments containing corrosive gases, and ventilation measures must be taken when installation is necessary.

      d、 For installation, maintenance, upkeep, and convenience, there needs to be ample installation space around the flowmeter.

      e、 The installation site of the flowmeter should avoid strong magnetic fields and vibration sources. If the pipeline vibration is large, there should be fixed pipe supports on both sides of the flowmeter.