During the verification, a 300kN standard force gauge and a 30 ton column structure force sensor were used
Category:
Instrumentation/Standard measuring instruments/Mechanical metrological standard instruments
Model:
During the verification, a 300kN standard force gauge and a 30 ton column structure force sensor wer
Brand:
Youzhongli
model:
During the verification, a 300kN standard force gauge and a 30 ton column structure force sensor were used
measurement object:
force value
Type of force measurement:
pressure
measurement range:
processing
measurement accuracy:
0.1 level
Scope of Application:
0-300kN
Processing & Customization:
No
Overall dimensions:
-
weight:
forty-five
Place of Origin:
Shenzhen
manufacturer:
Youzhongli
Retail Price
280.00USD
重量
kg
- Product Description
-
model During the verification, a 300kN standard force gauge and a 30 ton column structure force sensor were used
measurement object force value
Type of force measurement pressure
measurement range processing
measurement accuracy 0.1 level
Scope of Application 0-300kN
Processing & Customization No
Overall dimensions -
weight forty-five
Place of Origin Shenzhen
manufacturer Youzhongli
Description :
During the verification period, a 300kN standard force measuring instrument was used, and a 30 ton column structure force sensor was introducedShenzhen Youzhongli Technology Co., Ltd. has built a team in the field of automation based on years of understanding and knowledge in the automation field, always adhering to the enterprise operation concept of "because, therefore convincing". We provide customers with first-class pre-sales and after-sales technical services, and offer customers first-class quality and stable products. We always adhere to the principles of independent innovation, quality-oriented, and scientific management, and always provide perfect product and system solutions to meet customer needs to the fullest extent.
A standard force gauge is a highly accurate and reliable force (torque) measurement instrument. After years of improvement, this instrument can be applied in fields such as force (or torque) measurement, weighing control, sensor adjustment and detection, material performance testing, stress-strain measurement, transient peak measurement, etc. It has the advantages of high reliability and stability, complete functions, high measurement accuracy, convenient use, and intuitive display. It is the most ideal tool for measurement technology institutions to transmit, verify, calibrate, and perform performance testing of force, quality, hardness, etc.
placement time
The force measuring instrument should be placed for a sufficient period of time under the calibration conditions to ensure that the temperature is the same as and hidden under the calibration conditions. The recommended placement time for the force gauge is not less than 8 hours.
During the verification process, there should be no vibration, impact, electromagnetic field, or other interference sources around that could affect the verification results
1.4 Preheating
Verify that the corresponding variable force measuring instrument (or other force measuring instruments with power supply system) is powered on and preheated. The preheating time should comply with the manufacturer's regulations.
Note: The manufacturer does not specify the preheating time for the force gauge, which is generally preheated for 30 minutes to 1 hour.
1.5 Loading conditions
The installation of the force measuring instrument should ensure that its main axis coincides with the loading axis of the force base (standard) machine.
1.5.2 Compression force gauges should generally be equipped with upper and lower pressure pads. The supporting surface and bottom surface of the force measuring instrument should be flat and free from rust, scratches, and debris.
1.5.3 Suitable connectors should be used at both ends of the tensile force measuring instrument, and the connectors should ensure that the force base (standard) machine can safely apply axial force to the force measuring instrument.
1.6 Verification equipment
The principle of expanding the uncertainty of the force value of the force base (standard) machine or loading device for verifying various levels of standard force measuring instruments is three times the long-term stability or indication error index of the tested force instrument.
During the verification, a 300kN standard force gauge and a 30 ton column structure force sensor were used:



Mainly used for the calibration and verification of force measuring instruments and equipment such as material testing machines and presses. It can also be used for measuring, verifying, and calibrating the "force value" of other related instruments, equipment, components, and parts. Its prominent features are reliable data, stable quality, no aging, no wear and tear, and it belongs to a sex measuring instrument. It is an economical, easy-to-use, convenient, accurate and safe measuring instrument. It is a standard force measuring instrument for various quality and technical supervision, metrological testing, scientific research institutes, universities, quality inspection institutions, relevant departments, and enterprises
AfterSalesService :
Key words:- 30 ton column structure force sensor