Gansu 300 ton column type force sensor 3000kN measuring and testing standard force gauge
Gansu 300 ton column type force sensor 3000kN measuring and testing standard force gauge

Gansu 300 ton column type force sensor 3000kN measuring and testing standard force gauge

Category:

Instrumentation/Mechanical quantity instrument/Force measuring instrument

Model:

300 ton column type force sensor 3000kN measuring and testing standard force gauge

Brand:

Youzhongli

model:

300 ton column type force sensor 3000kN measuring and testing standard force gauge

Type of force measurement:

pull

display form:

Digital Display

type:

Digital force measuring instrument

measurement accuracy:

C3

Scope of Application:

electrical

measurement range:

0-500N

Processing & Customization:

No

weight:

one point four five

Place of Origin:

Shenzhen

manufacturer:

Shenzhen Youzhongli Technology Co., Ltd

Retail Price

180.00USD


重量

kg

  • Product Description
  • model

    300 ton column type force sensor 3000kN measuring and testing standard force gauge

    Type of force measurement

    pull

    display form

    Digital Display

    type

    Digital force measuring instrument

    measurement accuracy

    C3

    Scope of Application

    electrical

    measurement range

    0-500N

    Processing & Customization

    No

    weight

    one point four five

    Place of Origin

    Shenzhen

    manufacturer

    Shenzhen Youzhongli Technology Co., Ltd

    Description :

    Gansu 300 ton column type force sensor 3000kN measurement and testing standard force gauge product introductionMainly used for the calibration and verification of force measuring instruments and equipment such as material testing machines and presses. It can also be used for measuring, verifying, and calibrating the "force value" of other related instruments, equipment, components, and parts. Its prominent features are reliable data, stable quality, no aging, no wear and tear, and it belongs to a sex measuring instrument. It is an economical, easy-to-use, convenient, accurate and safe measuring instrument. It is a standard force measuring instrument for various quality and technical supervision, metrological testing, scientific research institutes, universities, quality inspection institutions, relevant departments, and enterprises

    Gansu 300 ton column type force sensor 3000kN measuring and testing standard force gauge

      Column type sensor: mainly used for measuring high force values and pressure applications, with a range of 500kN~50MN and the best range selection range of 1MN~20MN.

      Central perforated column type: The central perforated column type sensor is a commonly used structure in engineering testing, applied in a tensile or compressive direction, with average measuring performance, simple use, and low price. The range of measurement is 10kN~5MN, and the optimal range is 30kN~1MN.

      Shaft pin connection type: The shaft pin connection type pull sensor is mainly used for engineering tension measurement of high force values, with average measurement performance, easy installation, and a range of 200kN~10MN. The optimal range selection is 500kN~3MN.

      The force measuring instrument should be placed for a sufficient period of time under the calibration conditions to ensure that the temperature is the same as and hidden under the calibration conditions. The recommended placement time for the force gauge is not less than 8 hours.

      During the verification process, there should be no vibration, impact, electromagnetic field, or other interference sources around that could affect the verification results

      1.4 Preheating

      Verify that the corresponding variable force measuring instrument (or other force measuring instruments with power supply system) is powered on and preheated. The preheating time should comply with the manufacturer's regulations.

      Note: The manufacturer does not specify the preheating time for the force gauge, which is generally preheated for 30 minutes to 1 hour.

      1.5 Loading conditions

      The installation of the force measuring instrument should ensure that its main axis coincides with the loading axis of the force base (standard) machine.

      1.5.2 Compression force gauges should generally be equipped with upper and lower pressure pads. The supporting surface and bottom surface of the force measuring instrument should be flat and free from rust, scratches, and debris.

      1.5.3 Suitable connectors should be used at both ends of the tensile force measuring instrument, and the connectors should ensure that the force base (standard) machine can safely apply axial force to the force measuring instrument.

      1.6 Verification equipment

      The principle of expanding the uncertainty of the force value of the force base (standard) machine or loading device for verifying various levels of standard force measuring instruments is three times the long-term stability or indication error index of the tested force instrument.

    AfterSalesService :

    Key words:
    • 3000kN Measurement and Testing Standard Force Gauge