FBD mining explosion-proof ventilation fan 18.5kw press in explosion-proof ventilation fan
FBD mining explosion-proof ventilation fan 18.5kw press in explosion-proof ventilation fan

FBD mining explosion-proof ventilation fan 18.5kw press in explosion-proof ventilation fan

Category:

Environmental Protection/Fan exhaust equipment/Ventilation fan

Model:

FBDNO6.3/2×18.5

Brand:

Tai'an Hongyi

Retail Price

6,800.00USD


重量

kg

  • Product Description
  • Description :

      

      FBDNO6.3/218.5 explosion-proof ventilation fan for mining, press in explosion-proof ventilation fan, counter rotating local ventilation fan

      Customer requestFBDNO6.3/2 × 18.5 mining explosion-proof ventilation fanIt's our service standard,FBDNO6.3/2 × 18.5 mining explosion-proof ventilation fanValue contracts and ensure quality. It's difficult to win a customer and easy to lose one, so we takePressure type explosion-proof ventilation fanGood job, long-term cooperation.

      FBDNO6.3/218.5 explosion-proof ventilation fan for miningIntroduction:

      FBD series (formerly BDJ60 series) Pressure type explosion-proof ventilation fanIt is mainly used as a pressure type local ventilation fan in coal mines, suitable for local ventilation in mining faces and various chambers. At the same time, it is also suitable for local ventilation plants and various tunnel ventilation in other mines.

      FBDNO6.3/218.5 explosion-proof ventilation fan for miningModel representation:

      F represents local ventilation fan

      B represents * * type

      D represents the opposite rotation type

      No represents the machine number

      6.3 represents the diameter of the impeller

      2 represents dual motors

      18.5 represents power, 18.5 kilowatts

      FBDNO6.3/218.5 explosion-proof ventilation fan for miningMain technical parameters

      Model Rated speed Air volume Full wind pressure Pa External dimensions Weight kg

      FBD№4.02×2.2 2850 110-55 530-1850 1940×540×710 240

      FBD№4.52×5.5 2900 290 19400×560×800 360

      FBD№5.02×5.5 2900 220-1940×610×845 430

      FBD№5.02×7.5 2900 225-1940×610×845 450

      FBD№5.32×11 2930 290-2360×640×870 490

      FBD№5.62×11 2930 320-200 920-4280 2395×670×910 635

      FBD№5.62×60 600-4800 2395×670×910 670

      FBD№6.02×90 850-4900 2450×690×945 710

      FBD№6.02×18.5 2930 460-300 870-5000 2450×690×945 735

      FBD№6.02×22 2940 470-310 880-5100 2450×690×945 760

      FBD№6.32×18.5 2930 550-330 960-5300 2530×740×975 790

      FBD№6.32×22 2940 580-350 1000-5600 2530×740×975 870

      FBD№6.32×30 2950 600-380 1050-5800 2530×740×975 1030

      FBD№6.72×37 2950 670-435 1250-6800 2650×780×1015 1420

      FBD№7.12×37 2950 700-420 900-6800 2890×850×1085 1370

      FBD№7.12×45 2970 710-460 1000-7100 2890×850×1085 1510

      FBD№7.52×45 2970 610-400 800-7000 2960×880×1115 1580

      FBD№8.02×55 2970 950-600 050×916×1160 1860

      FBD№8.02×75 2970 1000-70 0 0×960×1195 2080

      FBDNO6.3/218.5 explosion-proof ventilation fan for miningOperation and maintenance use:

      Pressure type explosion-proof ventilation fanAfter the fan has been tested and found to be in good condition without any abnormalities, it can be started and put into formal operation. During the start-up and operation of the fan, no one is allowed to stand at the diffuser outlet. If any of the following situations are found during the operation of the fan, it should be stopped urgently for inspection. The fan can only be used after the cause is identified and repaired. (1) FBDNO6.3/218.5 explosion-proof ventilation fan for miningSudden and severe vibration of the fan or motor; The possible cause of the malfunction may be the detachment of the fan impeller counterweight, resulting in an imbalance of the impeller and requiring re balancing; (2) The temperature or current of the motor suddenly rises and exceeds the rated value. The possible cause of the malfunction may be an increase in motor load, which requires on-site inspection and analysis of the cause; The above situations require on-site inspection by repair personnel, analysis of the cause, and taking measures. Non personnel are not allowed to move without permission. You can also contact the manufacturer. Maintenance: (1) FBD seriesPressure type explosion-proof ventilation fanGenerally designed for horizontal installation, its service life should not be less than 4 years, and the safe operation time before the second major overhaul should not be less than 12000 hours; (2) Check the firmness of the bolts and nuts of each connecting component of the fan every 6 months of operation, and whether there are cracks or open welds in the blades and other parts; (3) If you need to replace motor components, you need to choose the same motor manufacturer's product.

    AfterSalesService :

    Key words: