MODEL100 online dust concentration sensor bag dust collector leak detector
MODEL100 online dust concentration sensor bag dust collector leak detector

MODEL100 online dust concentration sensor bag dust collector leak detector

Category:

Instrumentation/Gas analyzer/Dust detector

Model:

MODEL100

Brand:

Jingcheng Instrument

model:

MODEL100

sampling flow:

two

Measurement range:

customizable

measurement time:

one

measurement accuracy:

zero point one

Product Type:

Online dust analyzer

Working Voltage:

two hundred and twenty

type:

Online dust analyzer

flow range:

0-2L

output method:

4-20mA

Temperature control range:

one

noise:

one

Applicable Industries:

one

size:

one

manufacturer:

Qingdao Jingcheng Instrument

Retail Price

2,600.00USD


重量

kg

  • Product Description
  • model

    MODEL100

    sampling flow

    two

    Measurement range

    customizable

    measurement time

    one

    measurement accuracy

    zero point one

    Product Type

    Online dust analyzer

    Working Voltage

    two hundred and twenty

    type

    Online dust analyzer

    flow range

    0-2L

    output method

    4-20mA

    Temperature control range

    one

    noise

    one

    Applicable Industries

    one

    size

    one

    manufacturer

    Qingdao Jingcheng Instrument

    Description :

      1MODEL100Overview of bag dust collector leak detector:

      The MODEL100 bag filter leak detector measures the electrostatic induction of dust particles passing through a fixed probe. Dust particles and probes induce static charges, which are amplified by the probe and transmitted to the monitoring and control system. The size of static charge is proportional to the flow rate of dust particles. The high-tech electronic circuit of the MODEL100 bag dust collector leak detector converts this part of the charge into a control signal output, triggering the alarm for excessive dust emissions, and continuously recording the total amount or concentration of dust particles. This device provides the latest communication coupling technology in the world. This is a modern, accurate, and stable monitoring technology, particularly suitable for continuous emission recording and data accumulation. The working principle of this monitoring system is to use the charge induction generated by the flow of dust particles around the probe to confirm the online emission amount (mg/sec) or emission concentration (mg/m3) of dust particles. In the case of relatively stable combustion conditions (i.e., at the same emission point, there is no significant change in flow rate, temperature, pressure, humidity, and smoke particle properties, with a variation of less than ± 90%), the MODEL100 bag filter leak detector can also be used for online monitoring of emission concentration (unit=mg/M3) after direct calibration.

      IIMODEL100Technical parameters of bag dust collector leak detector:

      Operating environment temperature: -20 ℃~60 ℃ (electronic components);

      Operating environment humidity: 90% without condensation;

      Operating environment vibration: continuous oscillation, any direction, any frequency: root mean square value 2g (20m/s2);

      Operating environment electromagnetic field: can reach a value of=60 A/m at 50 Hz (equivalent to a magnetic field of 50 AT in a 1 meter x 1 meter square electromagnetic coil);

      Operating environment protection: Protection level: IP66/NEMA4 aluminum alloy shell, suitable for installation in non corrosive environments, stainless steel probe;

      Pipeline gas pressure: -0.1~1MPa;

      Pipeline gas flow velocity: 1m/s to 30m/s;

      Pipeline gas temperature: -50 ℃~450 ℃;

      Outer diameter of pipeline: 0.1 meters to 4 meters;

      Probe structure: The standard probe is M6, with a length of 160 mm and a 316 stainless steel rod;

      Dust particle size range: 0.1 μ M to 200 μ M, can still be received outside the nominal range, but the signal characteristics are slightly different;

      Zero drift: (time) less than 1% of the range per year;

      Within the temperature range, below 1% of the measuring range;

      Full range drift: (time) less than 1% of the range per year;

      Within the temperature range, below 1% of the measuring range;

      Line stability: All components of the system are made of high stability electronic assemblies;

      Noise resistance: All 50 or 60 Hz audio and harmonics are filtered out before the signal is received;

      Measurement range: 0-9/12/25/50/100/200/400/800/1000 mg/M3;

      Transmitter output mode: two-wire 4-20mA (built-in isolator, explosion-proof and anti-interference);

      Transmitter power supply: 15V-32VDC.

      About Jingcheng

    AfterSalesService :

    Key words:
    • Bag dust collector leak detector