Total Phosphorus Online Analyzer Cabinet style Sewage Quality Real time Monitoring Total Phosphorus Automatic Detection Equipment
Category:
Environmental Protection/Analytical instruments/Water quality online monitoring system
Model:
SZ-TP
Brand:
Jingcheng Instrument
model:
SZ-TP
Working Voltage:
AC230±10%V
measurement accuracy:
± 5% or ± 0.02mg/L (whichever is greater)
structural style :
cabinet-type
Temperature control range:
Suggested temperature: 15-25 ℃
Product Type:
Online instruments
Processing & Customization:
yes
power:
50—60Hz,5A
weight:
50KG
Scope of Application:
0—2mg/L 0.1—10mg/L 0.5—500mg/L
Place of Origin:
Qingdao
manufacturer:
Qingdao Jingcheng
Retail Price
18,500.00USD
重量
kg
- Product Description
-
model SZ-TP
Working Voltage AC230±10%V
measurement accuracy ± 5% or ± 0.02mg/L (whichever is greater)
structural style cabinet-type
Temperature control range Suggested temperature: 15-25 ℃
Product Type Online instruments
Processing & Customization yes
power 50—60Hz,5A
weight 50KG
Scope of Application 0—2mg/L 0.1—10mg/L 0.5—500mg/L
Place of Origin Qingdao
manufacturer Qingdao Jingcheng
Description :


Total phosphorus online analyzer
cabinet-type
1、 SZ-TP Total Phosphorus Online Analyzer Product Overview:
The harm of phosphorus to marine organisms, most of which are highly sensitive to organophosphate pesticides. The concentration of pesticides that some drug-resistant insects do not respond to can quickly cause the death of marine organisms. There is an important neurotransmitter acetylcholinesterase in the human body. Organophosphorus can inhibit acetylcholinesterase, making it unable to decompose acetylcholinesterase and causing a large accumulation of acetylcholinesterase in the central nervous system, leading to poisoning. Severe cases may even lead to death. Long term low-dose organophosphate pesticides can not only cause chronic poisoning in humans, but may also pose hazards such as carcinogenesis and teratogenicity.
Water Quality Tester
2、 SZ-TP Total Phosphorus Online Analyzer Product Principle:
The mixture of water sample, catalyst solution, and strong oxidant digestion solution is heated to 120 ℃. Polyphosphate and other phosphorus containing compounds in the water sample are digested and oxidized by the strong oxidant under acidic conditions of high temperature and high pressure to generate phosphate ions. In the presence of the catalyst, phosphate ions form a colored complex in a strong acid solution containing molybdate. The analyzer detects the color change and converts it into total phosphorus value output. The amount of colored complex generated is equivalent to the total phosphorus content. This product is a single factor parameter testing and analysis instrument, and this method is suitable for wastewater with phosphorus in the range of 0-500mg/L. For wastewater detection containing a large amount of organic matter, the measurement results may be underestimated.
485 signal output
3、 Technical parameters of SZ-TP total phosphorus online analyzer:
Specification Name
Technical specifications and parameters
measurement range
(switchable)
0—2mg/L
0.1—10mg/L
0.5—500mg/L
measurement method
Phosphomolybdate spectrophotometric method
detection limit
0.001mg/L
resolution
zero point zero zero one
accuracy
± 5% or ± 0.02mg/L (whichever is greater)
repetitiveness
± 5% or ± 0.02mg/L (whichever is greater)
zero drift
±5%
Span Drift
±10%
measurement period
The small measurement cycle is 20 minutes, and the digestion time can be set between 5-60 minutes
sampling period
Interval, hourly, and trigger modes can be adjusted
calibration cycle
Automatic calibration 1-99 days adjustable
maintenance cycle
Over 1 month, approximately 1 hour per session
Human machine operation
Touch screen display and command input
Self checking protection
Abnormal or power outage data not lost
After abnormal reset or power outage, residual liquid will be automatically eliminated and work will resume
data storage
1 year of data storage
input interface
discrete signal
output interface
1 RS232 channel; 2-channel 4-20mA
working environment
Suggested temperature: 15-25 ℃
Operating Humidity
≤ 90% (non condensing)
Power Supply and Power
AC230±10%V;50—60Hz,5A
size
1500*550*450mm
real-time monitoring
AfterSalesService :
Key words:- Total phosphorus online analyzer
More Products