Total Phosphorus Online Analyzer Cabinet style Sewage Quality Real time Monitoring Total Phosphorus Automatic Detection Equipment
Total Phosphorus Online Analyzer Cabinet style Sewage Quality Real time Monitoring Total Phosphorus Automatic Detection Equipment

Total Phosphorus Online Analyzer Cabinet style Sewage Quality Real time Monitoring Total Phosphorus Automatic Detection Equipment

Category:

Environmental Protection/Analytical instruments/Water quality online monitoring system

Model:

SZ-TP

Brand:

Jingcheng Instrument

model:

SZ-TP

Working Voltage:

AC230±10%V

measurement accuracy:

± 5% or ± 0.02mg/L (whichever is greater)

structural style :

cabinet-type

Temperature control range:

Suggested temperature: 15-25 ℃

Product Type:

Online instruments

Processing & Customization:

yes

power:

50—60Hz,5A

weight:

50KG

Scope of Application:

0—2mg/L 0.1—10mg/L 0.5—500mg/L

Place of Origin:

Qingdao

manufacturer:

Qingdao Jingcheng

Retail Price

18,500.00USD


重量

kg

  • Product Description
  • model

    SZ-TP

    Working Voltage

    AC230±10%V

    measurement accuracy

    ± 5% or ± 0.02mg/L (whichever is greater)

    structural style

    cabinet-type

    Temperature control range

    Suggested temperature: 15-25 ℃

    Product Type

    Online instruments

    Processing & Customization

    yes

    power

    50—60Hz,5A

    weight

    50KG

    Scope of Application

    0—2mg/L 0.1—10mg/L 0.5—500mg/L

    Place of Origin

    Qingdao

    manufacturer

    Qingdao Jingcheng

    Description :

      

      

      Total phosphorus online analyzer

      cabinet-type

      1、 SZ-TP Total Phosphorus Online Analyzer Product Overview:

      The harm of phosphorus to marine organisms, most of which are highly sensitive to organophosphate pesticides. The concentration of pesticides that some drug-resistant insects do not respond to can quickly cause the death of marine organisms. There is an important neurotransmitter acetylcholinesterase in the human body. Organophosphorus can inhibit acetylcholinesterase, making it unable to decompose acetylcholinesterase and causing a large accumulation of acetylcholinesterase in the central nervous system, leading to poisoning. Severe cases may even lead to death. Long term low-dose organophosphate pesticides can not only cause chronic poisoning in humans, but may also pose hazards such as carcinogenesis and teratogenicity.

      Water Quality Tester

      2、 SZ-TP Total Phosphorus Online Analyzer Product Principle:

      The mixture of water sample, catalyst solution, and strong oxidant digestion solution is heated to 120 ℃. Polyphosphate and other phosphorus containing compounds in the water sample are digested and oxidized by the strong oxidant under acidic conditions of high temperature and high pressure to generate phosphate ions. In the presence of the catalyst, phosphate ions form a colored complex in a strong acid solution containing molybdate. The analyzer detects the color change and converts it into total phosphorus value output. The amount of colored complex generated is equivalent to the total phosphorus content. This product is a single factor parameter testing and analysis instrument, and this method is suitable for wastewater with phosphorus in the range of 0-500mg/L. For wastewater detection containing a large amount of organic matter, the measurement results may be underestimated.

      485 signal output

      3、 Technical parameters of SZ-TP total phosphorus online analyzer:

      Specification Name

      

      Technical specifications and parameters

      

      measurement range

      (switchable)

      

      0—2mg/L

      

      0.1—10mg/L

      

      0.5—500mg/L

      

      measurement method

      

      Phosphomolybdate spectrophotometric method

      

      detection limit

      

      0.001mg/L

      

      resolution

      

      zero point zero zero one

      

      accuracy

      

      ± 5% or ± 0.02mg/L (whichever is greater)

      

      repetitiveness

      

      ± 5% or ± 0.02mg/L (whichever is greater)

      

      zero drift

      

      ±5%

      

      Span Drift

      

      ±10%

      

      measurement period

      

      The small measurement cycle is 20 minutes, and the digestion time can be set between 5-60 minutes

      

      sampling period

      

      Interval, hourly, and trigger modes can be adjusted

      

      calibration cycle

      

      Automatic calibration 1-99 days adjustable

      

      maintenance cycle

      

      Over 1 month, approximately 1 hour per session

      

      Human machine operation

      

      Touch screen display and command input

      

      Self checking protection

      

      Abnormal or power outage data not lost

      

      After abnormal reset or power outage, residual liquid will be automatically eliminated and work will resume

      

      data storage

      

      1 year of data storage

      

      input interface

      

      discrete signal

      

      output interface

      

      1 RS232 channel; 2-channel 4-20mA

      

      working environment

      

      Suggested temperature: 15-25 ℃

      

      Operating Humidity

      

      ≤ 90% (non condensing)

      

      Power Supply and Power

      

      AC230±10%V;50—60Hz,5A

      

      size

      

      1500*550*450mm

      real-time monitoring

      

    AfterSalesService :

    Key words:
    • Total phosphorus online analyzer