Online ammonia nitrogen detector, real-time monitoring of ammonia nitrogen content, cabinet type salicylic acid colorimetric water quality analyzer
Online ammonia nitrogen detector, real-time monitoring of ammonia nitrogen content, cabinet type salicylic acid colorimetric water quality analyzer

Online ammonia nitrogen detector, real-time monitoring of ammonia nitrogen content, cabinet type salicylic acid colorimetric water quality analyzer

Category:

Environmental Protection/Analytical instruments/Water quality online monitoring system

Model:

SZ-NH

Brand:

Jingcheng Instrument

model:

SZ-NH

Working Voltage:

AC230±10%V

measurement accuracy:

± 5% or ± 0.02mg/L (whichever is greater)

structural style :

cabinet-type

Temperature control range:

Suggested temperature: 15-25 ℃

Product Type:

Online instruments

Processing & Customization:

No

power:

50—60Hz,5A

weight:

fifty

Scope of Application:

0—3mg/L 0.1—10mg/L 0.2—30mg/L 1—100mg/L 10—500mg/L

Place of Origin:

Qingdao

manufacturer:

Qingdao Jingcheng

Retail Price

18,500.00USD


重量

kg

  • Product Description
  • model

    SZ-NH

    Working Voltage

    AC230±10%V

    measurement accuracy

    ± 5% or ± 0.02mg/L (whichever is greater)

    structural style

    cabinet-type

    Temperature control range

    Suggested temperature: 15-25 ℃

    Product Type

    Online instruments

    Processing & Customization

    No

    power

    50—60Hz,5A

    weight

    fifty

    Scope of Application

    0—3mg/L 0.1—10mg/L 0.2—30mg/L 1—100mg/L 10—500mg/L

    Place of Origin

    Qingdao

    manufacturer

    Qingdao Jingcheng

    Description :

      Online ammonia nitrogen detector

      24-hour real-time monitoring

      1、 SZ-NH Ammonia Nitrogen Online Analyzer Product Overview:

      Ammonia nitrogen in water refers to the nitrogen present in the form of free nitrogen, mainly derived from the decomposition products of nitrogen-containing organic matter in domestic sewage by microbial action, industrial wastewater such as coking and ammonia synthesis, and agricultural drainage. When the ammonia nitrogen content in water is high, it exhibits toxic effects on fish and poses varying degrees of harm to humans. The determination of ammonia nitrogen content in water is helpful in evaluating the pollution and "self purification" status of water bodies, therefore ammonia nitrogen is an important indicator for characterizing water quality pollution.

      This analyzer is capable of long-term automatic continuous operation according to on-site settings, and is widely applicable to industrial pollution source discharge wastewater, industrial process wastewater, industrial wastewater treatment plant wastewater, municipal wastewater treatment plant wastewater, and other occasions. According to the complexity of the on-site testing conditions, corresponding preprocessing systems can be selected to ensure the reliability of the testing process, accurate testing results, and fully meet the on-site requirements of different occasions.

      Ammonia nitrogen content detection

      2、 SZ-NH Ammonia Nitrogen Online Analyzer Product Principle:

      This product uses the salicylic acid colorimetric determination method. After mixing the water sample and masking agent, ammonia nitrogen in the form of free ammonia or ammonium ions reacts with salicylate ions and hypochlorous acid ions in an alkaline environment and in the presence of sensitizers to form a colored complex. The analyzer detects the color change and converts it into ammonia nitrogen value for output. The amount of colored complex generated is equivalent to the content of ammonia nitrogen. This method is applicable to wastewater with ammonia nitrogen in the range of 0-300mg/L. Excessive calcium and magnesium ions, residual chlorine, or turbidity may interfere with the measurement.

      485 signal output

      3、 Technical parameters of SZ-NH ammonia nitrogen online analyzer:

      Specification Name

      

      Technical specifications and parameters

      

      measurement range

      (switchable)

      

      0—3mg/L

      

      0.1—10mg/L

      

      0.2—30mg/L

      

      1—100mg/L

      

      10—500mg/L

      

      measurement method

      

      Salicylic acid spectrophotometric colorimetric method

      

      detection limit

      

      0.01mg/L

      

      resolution

      

      zero point zero one

      

      accuracy

      

      ± 5% or ± 0.02mg/L (whichever is greater)

      

      repetitiveness

      

      2%

      

      zero drift

      

      ±0.02mg/L

      

      Span Drift

      

      ±1%

      

      measurement period

      

      The small measurement cycle is 20 minutes, and the digestion time can be set between 5-60 minutes

      

      sampling period

      

      Interval, hourly, and trigger modes can be adjusted

      

      maintenance cycle

      

      Over 1 month, approximately 1 hour per session

      

      Self checking protection

      

      Abnormal or power outage data not lost

      

      After abnormal reset or power outage, residual liquid will be automatically eliminated and work will resume

      

      data storage

      

      1 year of data storage

      

      output interface

      

      1 RS232 channel; Route 1 4-20mA

      

      working environment

      

      Suggested temperature: 15-25 ℃

      

      Power Supply and Power

      

      AC230±10%V;50—60Hz,5A

      

      size

      

      1500*550*450mm

      Water Quality Analyzer

      

    AfterSalesService :

    Key words:
    • Online ammonia nitrogen detector