Total nitrogen online analyzer for real-time monitoring of water quality and total nitrogen indicators. It can be connected to the network for environmental protection and sewage detection
Total nitrogen online analyzer for real-time monitoring of water quality and total nitrogen indicators. It can be connected to the network for environmental protection and sewage detection

Total nitrogen online analyzer for real-time monitoring of water quality and total nitrogen indicators. It can be connected to the network for environmental protection and sewage detection

Category:

Environmental Protection/Analytical instruments/Water quality online monitoring system

Model:

SZ-TN

Brand:

Jingcheng Instrument

model:

SZ-TN

Working Voltage:

AC230±10%V

measurement accuracy:

± 5% or ± 0.1mg/L (whichever is greater)

structural style :

cabinet-type

Temperature control range:

Suggested temperature: 15-25 ℃

Product Type:

Online instruments

Processing & Customization:

No

power:

50—60Hz,5A

weight:

fifty

Scope of Application:

0.1—5mg/L 2—20mg/L 10—500mg/L

Place of Origin:

Qingdao

manufacturer:

Qingdao Jingcheng

Retail Price

19,500.00USD


重量

kg

  • Product Description
  • model

    SZ-TN

    Working Voltage

    AC230±10%V

    measurement accuracy

    ± 5% or ± 0.1mg/L (whichever is greater)

    structural style

    cabinet-type

    Temperature control range

    Suggested temperature: 15-25 ℃

    Product Type

    Online instruments

    Processing & Customization

    No

    power

    50—60Hz,5A

    weight

    fifty

    Scope of Application

    0.1—5mg/L 2—20mg/L 10—500mg/L

    Place of Origin

    Qingdao

    manufacturer

    Qingdao Jingcheng

    Description :

      Total nitrogen online analyzer

      24-hour real-time monitoring

      1、 Overview of SZ-TN Total Nitrogen (TN) Online Automatic Monitoring Instrument:

      The total nitrogen in water mainly comes from the decomposition products of nitrogen-containing organic compounds in domestic sewage by microbial action, industrial wastewater such as coking and ammonia synthesis, and agricultural drainage. When the total nitrogen content in water is high, it exhibits toxic effects on fish and poses varying degrees of harm to humans. Measuring the total nitrogen content in water helps to evaluate the pollution and self purification status of water bodies, therefore total nitrogen is an important indicator for characterizing water quality pollution.

      Internet connected environmental protection

      2、 SZ-TN Total Nitrogen (TN) Online Automatic Monitoring Instrument Product Principle:

      In the presence of potassium persulfate, nitrogen-containing compounds in the water sample undergo high digestion and are completely converted into nitrate nitrogen. After cooling to room temperature, they react with the indicator to form a colored complex. The analyzer detects this color change and converts it into the total nitrogen value for output. The amount of colored complex generated is equivalent to the total nitrogen content. This method is applicable to wastewater with total nitrogen in the range of 0-50mg/L. Excessive calcium and magnesium ions, residual chlorine, or turbidity may interfere with the measurement.

      Sewage detection equipment

      3、 Technical parameters of SZ-TN total nitrogen (TN) online automatic monitoring instrument:

      Specification Name

      

      Technical specifications and parameters

      

      measurement range

      (switchable)

      

      0.1—5mg/L

      

      2—20mg/L

      

      10—500mg/L

      

      measurement method

      

      Potassium persulfate digestion spectrophotometric detection

      

      detection limit

      

      0.001mg/L

      

      resolution

      

      zero point zero zero one

      

      accuracy

      

      ± 5% or ± 0.1mg/L (whichever is greater)

      

      repetitiveness

      

      ± 5% or ± 0.1mg/L (whichever is greater)

      

      zero drift

      

      ±5%

      

      Span Drift

      

      ±5%

      

      measurement period

      

      The small measurement cycle is 20 minutes, and the digestion time can be set between 5-60 minutes

      

      sampling period

      

      Interval, hourly, and trigger modes can be adjusted

      

      calibration cycle

      

      Automatic calibration 1-99 days adjustable

      

      maintenance cycle

      

      Over 1 month, approximately 1 hour per session

      

      Human machine operation

      

      Touch screen display and command input

      

      Self checking protection

      

      Abnormal or power outage data not lost

      

      After abnormal reset or power outage, residual liquid will be automatically eliminated and work will resume

      

      data storage

      

      1 year of data storage

      

      input interface

      

      discrete signal

      

      output interface

      

      1 RS232 channel; Route 1 4-20mA

      

      working environment

      

      Suggested temperature: 15-25 ℃

      

      Operating Humidity

      

      ≤ 90% (non condensing)

      

      Power Supply and Power

      

      AC230±10%V;50—60Hz,5A

      

      size

      

      1500*550*450mm

      

      Water Quality Tester

    AfterSalesService :

    Key words:
    • Total nitrogen online analyzer