Online turbidity meter for 24-hour real-time monitoring of water quality turbidity, environmentally friendly networked turbidity detector
Online turbidity meter for 24-hour real-time monitoring of water quality turbidity, environmentally friendly networked turbidity detector

Online turbidity meter for 24-hour real-time monitoring of water quality turbidity, environmentally friendly networked turbidity detector

Category:

Environmental Protection/Analytical instruments/Water quality online monitoring system

Model:

SZ-ZD

Brand:

Jingcheng Instrument

model:

SZ-ZD

Working Voltage:

AC 220V ± 10% (instrument and circulation type) DC 12V( Submerged&# 41;

measurement accuracy:

±1.0%FS,±0.5℃

structural style :

wall-mounted

Temperature control range:

0~60℃

Product Type:

Online instruments

Processing & Customization:

No

weight:

0.9kg (Instrument) 2.0kg (Submerged) 3.5kg&# 40; Circulating&# 41;

Scope of Application:

0-200NTU (flow-through), 0-10000NTU (submerged), customizable range

Place of Origin:

Qingdao

manufacturer:

Qingdao Jingcheng

Retail Price

4,500.00USD


重量

kg

  • Product Description
  • model

    SZ-ZD

    Working Voltage

    AC 220V ± 10% (instrument and circulation type) DC 12V( Submerged&# 41;

    measurement accuracy

    ±1.0%FS,±0.5℃

    structural style

    wall-mounted

    Temperature control range

    0~60℃

    Product Type

    Online instruments

    Processing & Customization

    No

    weight

    0.9kg (Instrument) 2.0kg (Submerged) 3.5kg&# 40; Circulating&# 41;

    Scope of Application

    0-200NTU (flow-through), 0-10000NTU (submerged), customizable range

    Place of Origin

    Qingdao

    manufacturer

    Qingdao Jingcheng

    Description :

      Online turbidity meter

      24-hour monitoring

      1. Product configuration

      Please confirm if the packaging box of the detector you purchased is complete. If there is any packaging damage or shortage of any accessories, please contact the responsible person as soon as possible. The configuration is as follows

      Standard Configuration

      ◇ One instrument

      ◇ One circulating/sinking turbidity sensor

      ◇ Tighten two locking strips

      ◇ One user manual

      ◇ Clean one brush (circulating type)

      ◇ Two water stop clamps (flow type)

      ◇ Three meter water pipeline (circulating type)

      optional

      ◇ Installation bracket (1 meter long) (sunken type)

      ◇ 485 communication interface and 485 to 232 or 485 to USB connector

      Environmentally friendly networking

      2. Product Introduction

      Online turbidity refers to the degree of obstruction caused by suspended solids in water to the transmission of light. Water containing soil, silt, fine organic matter, and other microorganisms and colloids can cause turbidity in the water. The light waves emitted by the transmitter on the sensor are absorbed, reflected, and scattered by the measured object during transmission. Some of the transmitted light can be directed towards the detector in the 180 ° direction, while some of the scattered light can be directed towards the detector in the 90 ° direction. The intensity of light received by detectors in the 180 ° and 90 ° directions is related to the turbidity of the measured wastewater. Therefore, by measuring the intensity of transmitted and scattered light, the turbidity of the wastewater can be calculated.

      Turbidity detector

      Key Features:

      The internal structure effectively eliminates water bubbles, improves measurement accuracy and stability (flow type).

      By disassembling the water outlet connector module, the optical path lens and the inner wall of the flow channel can be cleaned, making maintenance more convenient (flow type).

      ◇ Internal upgrade of the sensor effectively prevents moisture and dust accumulation in the internal circuit, avoiding damage to the internal circuit (flow type).

      Built in zero position adjustment potentiometer, sensor can be mechanically zeroed (flow-through).

      The sensor housing is made of 316L stainless steel, which has good corrosion resistance (submerged type).

      The turbidity sensor is not affected by sample flow rate and pressure (submerged type).

      The infrared light waves emitted by the transmitter on the sensor use a stable invisible near monochromatic infrared light source, which avoids the interference of chromaticity in the liquid and visible light from the outside on the sensor measurement.

      The sensor uses a quartz glass lens with extremely high transmittance on the optical path, which makes the emission and reception of infrared light waves more stable; And built-in photometric compensation to improve measurement accuracy.

      The instrument adopts a brand new waterproof, dustproof, and moisture-proof shell (IP65) technology, with a surface painting process and a generous appearance.

      ◇ Wide range, stable measurement, high accuracy, good reproducibility, and strong anti-interference ability.

      Communication function: Equipped with RS-485 communication interface (partially compatible with MODBUS protocol) (optional); Optoelectronic isolation with 4-20 mA current output, the corresponding value can be set arbitrarily.

      ◇ The function of setting the hysteresis value arbitrarily avoids frequent actions of the switch relay, and has the function of setting the switch value to turn off and off.

      ◇ Adopting two-point calibration method, the instrument range can be modified.

      Watchdog function: Ensure that the instrument panel does not crash.

      ◇ Power failure protection>10 years.

      Water Quality Analyzer

      3. Technical indicators

      Measurement range: 0-200NTU (flow-through), 0-10000NTU (submerged), customizable range

      Resolution: 0.01%, 0.1 ℃

      Accuracy: ± 1.0% FS, ± 0.5 ℃

      Repeatability: ± 1.0%

      Control interface: Two sets of ON/OFF relay contacts, divided into high and low point alarm signal photoelectric isolation outputs.

      Signal isolation output: Optocoupler isolation protection 4-20mA signal output

      Relay: Relay hysteresis can be set arbitrarily, relay load 3A 220VAC/24VDC

      Working conditions: The ambient temperature is 0-60 ℃, and the relative humidity is ≤ 90%

      Output load: load<500 Ω (0-10mA), load<750 Ω (4-20mA)

      10. Working voltage: AC 220V ± 10% (instrument and circulation type), DC 12V (submerged type)

      11. Size: 96 * 96 * 168mm (instrument) 380 * 270 * 80mm (flow-through)

      237 * φ 64mm (submerged)

      Hole size: 92 * 92mm

      Weight: 0.9kg (instrument) 2.0kg (submerged) 3.5kg (flow-through)

      Protection level: IP65 (instrument), IP68 (submerged), IP67 (flowing internal)

    AfterSalesService :

    Key words:
    • Online turbidity meter