BOD analyzer Microbial electrical method Biochemical oxygen demand BOD rapid analyzer
Category:
Instrumentation/Analytical instruments/Water quality analyzer
Model:
LB-50A
Brand:
Jingcheng Instrument
model:
LB-50A
type:
Rapid water quality analyzer
Processing & Customization:
No
measurement range:
2-50 mg/L (can measure 2-5000 mg/L)
measurement accuracy:
zero point zero one
power supply voltage:
AC220V 50Hz
resolution:
zero point zero one
Place of Origin:
Shandong
manufacturer:
Qingdao Jingcheng
Retail Price
11,500.00USD
重量
kg
- Product Description
-
model LB-50A
type Rapid water quality analyzer
Processing & Customization No
measurement range 2-50 mg/L (can measure 2-5000 mg/L)
measurement accuracy zero point zero one
power supply voltage AC220V 50Hz
resolution zero point zero one
Place of Origin Shandong
manufacturer Qingdao Jingcheng
Description :
1BOD analyzer Microbial electrical method Biochemical oxygen demand BOD rapid analyzer Measurement principle
The LB-50A BOD rapid analyzer adopts the microbial electrode method, in which the microbial membrane is tightly attached to the surface of the oxygen permeable membrane of the polarographic dissolved oxygen electrode, forming the microbial electrode. The instrument adopts a flow measurement method, which means that the sample flows through the microbial electrode. The microbial membrane contains a large number of aerobic microorganisms, which are very active in aerobic and organic environments. The output current of the oxygen electrode is proportional to the concentration of dissolved oxygen. When a liquid without organic matter passes through the flow cell, the dissolved oxygen passing through the microbial membrane hardly decreases. When a solution containing organic matter passes through a circulation pool, microorganisms consume a large amount of dissolved oxygen, which is proportional to the concentration of organic matter, resulting in a corresponding decrease in dissolved oxygen passing through the microbial membrane. The dissolved oxygen electrode measures the change in dissolved oxygen concentration to calculate the BOD value.
BOD rapid analyzer
IILB-50A BOD rapid analyzer execution standard
HJ/T 86-2002 "Determination of Biochemical Oxygen Demand (BOD) in Water Quality - Microbial Sensor Rapid Determination Method"
Bod detector
IIIMain features of LB-50A BOD rapid analyzer
1. Principle: Using microbial electrode method
2. Accurate results: Strong comparability with the five-day method
3. Easy to operate: microcomputer control, intelligent measurement
4. Short measurement time: Complete a sample measurement in 8 minutes
5. Easy maintenance: simply replace the biofilm and infusion tube regularly
6. Water samples do not require pre-treatment and have strong anti-interference ability
7. High safety, the strains used are harmless to the human body
8. High reliability: simple structure, no vulnerable components, long lifespan
9. Printing function: equipped with a micro printer, printing and outputting measurement results
Microbial electrode method
4Technical specifications of LB-50A BOD rapid analyzer
Measurement range: 2-50 mg/L (can measure 2-5000mg/L)
Repeatability: ≤ 5%
Sample testing time: 8 minutes
Injection method: Constant current continuous injection
Buffer solution consumption: 5ml/min
Required sample volume: 50ml required for each measurement
Environmental temperature: (5-40) ℃
Relative humidity: ≤ 90%
Power: 100W
Power supply: AC220V 50Hz
External dimensions: (560 × 360 × 210) mm
Weight: 16kg