Permanganate Index Online Monitoring Instrument for Industrial Wastewater Treatment Water Quality Inorganic Non Metallic Online Detection Instrument
Permanganate Index Online Monitoring Instrument for Industrial Wastewater Treatment Water Quality Inorganic Non Metallic Online Detection Instrument

Permanganate Index Online Monitoring Instrument for Industrial Wastewater Treatment Water Quality Inorganic Non Metallic Online Detection Instrument

Category:

Environmental Protection/Analytical instruments/Water quality online monitoring system

Model:

SZ-MnO4

Brand:

Jingcheng Instrument

model:

SZ-MnO4

Working Voltage:

AC230±10%V

measurement accuracy:

± 10% or ± 0.1mg/L (whichever is greater)

structural style :

cabinet-type

Temperature control range:

Suggested temperature: 15-25 ℃

Product Type:

Online inorganic non-metallic monitoring instrument

Processing & Customization:

No

power:

one hundred

Scope of Application:

0—5mg/L 0—20mg/L 0—50mg/L

Place of Origin:

Qingdao

manufacturer:

Qingdao Jingcheng

Retail Price

23,500.00USD


重量

kg

  • Product Description
  • model

    SZ-MnO4

    Working Voltage

    AC230±10%V

    measurement accuracy

    ± 10% or ± 0.1mg/L (whichever is greater)

    structural style

    cabinet-type

    Temperature control range

    Suggested temperature: 15-25 ℃

    Product Type

    Online inorganic non-metallic monitoring instrument

    Processing & Customization

    No

    power

    one hundred

    Scope of Application

    0—5mg/L 0—20mg/L 0—50mg/L

    Place of Origin

    Qingdao

    manufacturer

    Qingdao Jingcheng

    Description :

      Permanganate Index Online Monitoring Instrument

      Inorganic non-metallic detector

      1、 Product Overview of SZ-MnO4 Permanganate Water Quality Online Automatic Monitoring Instrument:

       Under certain conditions, using KMnO4Oxidation of certain organic and inorganic reducing substances in water samples, caused by the consumption of KMnO4The permanganate index, which is equivalent to the calculation of oxygen content, cannot be used as an indicator of theoretical oxygen demand or total organic matter content, because under specified conditions, many organic matter can only be partially oxidized, and volatile organic matter is not included in the measured values.

      Water Quality Analyzer

      2、 Product principle of SZ-MnO4 potassium permanganate water quality online automatic monitoring instrument:

       Add a known amount of K to the sampleMnO4Heat Liu acid in a boiling water bath for 30 minutes at KMnO4Oxidation of certain organic and inorganic reducing substances in the sample, followed by the addition of excess sodium oxalate to reduce the remainingKMnO4Then use K againMnO4Drip excess sodium oxalate back into the standard solution. Calculate the permanganate index in the sample.

      24-hour real-time monitoring

      3、 Technical parameters of SZ-MnO4 potassium permanganate water quality online automatic monitoring instrument:

      Specification Name

      

      Technical specifications and parameters

      

      measurement range

      

      0—5mg/L

      

      0—20mg/L

      

      0—50mg/L

      

      measurement method

      

      KMnO4Digestion spectrophotometry

      

      detection limit

      

      0.02mg/L

      

      resolution

      

      zero point zero zero one

      

      accuracy

      

      ± 10% or ± 0.1mg/L (whichever is greater)

      

      repetitiveness

      

      ± 10% or ± 0.1mg/L (whichever is greater)

      

      zero drift

      

      ±0.05mg/L

      

      Span Drift

      

      ±10%

      

      measurement period

      

      The small measurement cycle is 20 minutes, and the digestion time can be set between 5-60 minutes

      

      sampling period

      

      Interval, hourly, and trigger modes can be adjusted

      

      calibration cycle

      

      Automatic calibration 1-99 days adjustable

      

      maintenance cycle

      

      Over 1 month, approximately 1 hour per session

      

      Human machine operation

      

      Touch screen display and command input

      

      Self checking protection

      

      Abnormal or power outage data not lost

      

      After abnormal reset or power outage, residual liquid will be automatically eliminated and work will resume

      

      data storage

      

      1 year of data storage

      

      input interface

      

      discrete signal

      

      output interface

      

      1 RS232 channel; Route 1 4-20mA

      

      working environment

      

      Suggested temperature: 15-25 ℃

      

      Operating Humidity

      

      ≤ 90% (non condensing)

      

      Power Supply and Power

      

      AC230±10%V;50—60Hz,5A

      

      size

      

      1500*550*450mm

      Environmentally friendly networking

      

    AfterSalesService :

    Key words:
    • Permanganate Index Online Monitoring Instrument