Volatile phenol online analyzer cabinet type inorganic non-metallic real-time monitoring volatile phenol testing and detection equipment
Volatile phenol online analyzer cabinet type inorganic non-metallic real-time monitoring volatile phenol testing and detection equipment

Volatile phenol online analyzer cabinet type inorganic non-metallic real-time monitoring volatile phenol testing and detection equipment

Category:

Environmental Protection/Analytical instruments/Water quality online monitoring system

Model:

SZ-HHF

Brand:

Jingcheng Instrument

model:

SZ-HHF

Working Voltage:

AC230±10%V

measurement accuracy:

± 10% or ± 0.1mg/L (whichever is greater)

structural style :

cabinet-type

Temperature control range:

Suggested temperature: 15-25 ℃

Product Type:

Online inorganic non-metallic monitoring instrument

Processing & Customization:

No

power:

50—60Hz,5A

Scope of Application:

0—20mg/L

Place of Origin:

Qingdao

manufacturer:

Qingdao Jingcheng

Retail Price

26,000.00USD


重量

kg

  • Product Description
  • model

    SZ-HHF

    Working Voltage

    AC230±10%V

    measurement accuracy

    ± 10% or ± 0.1mg/L (whichever is greater)

    structural style

    cabinet-type

    Temperature control range

    Suggested temperature: 15-25 ℃

    Product Type

    Online inorganic non-metallic monitoring instrument

    Processing & Customization

    No

    power

    50—60Hz,5A

    Scope of Application

    0—20mg/L

    Place of Origin

    Qingdao

    manufacturer

    Qingdao Jingcheng

    Description :

      Volatile phenol online analyzer

      Real time monitoring of inorganic non-metallic materials

      1、 Product Overview of Volatile Phenol Online Analyzer:

      Whether phenols can be evaporated together with water vapor, they are divided into volatile phenols and non-volatile phenols. Volatile phenols mostly refer to phenols with boiling points below 23 ℃, usually belonging to monophenols. Phenols mainly come from wastewater from refining, gas washing, coking, papermaking, synthetic ammonia, wood preservation, and chemical industries.

      This analyzer is capable of long-term automatic continuous operation according to on-site settings, and is widely applicable to industrial pollution source discharge wastewater, industrial process wastewater, industrial wastewater treatment plant wastewater, municipal wastewater treatment plant wastewater, and other occasions. According to the complexity of the on-site testing conditions, corresponding preprocessing systems can be selected to ensure the reliability of the testing process, accurate testing results, and fully meet the on-site requirements of different occasions.

      Volatile phenol detection equipment

      2、 Product principle of volatile phenol online analyzer:

      When the concentration of volatile phenols in the water sample is below 0.5mg/L, 4-aminoantipyrine extraction photometry is used. When the concentration is above 0.5mg/L, 4-aminoantipyrine direct photometry is used. The measurement signal is input into the data processing system to automatically calculate the measurement results. Mainly used for online monitoring of surface water and groundwater quality in rivers and lakes, as well as online monitoring of water quality in water treatment plants. This product is suitable for wastewater with a concentration of 0-30mg/L.

      24-hour real-time monitoring

      3、 Technical parameters of volatile phenol online analyzer:

      Specification Name

      

      Technical specifications and parameters

      

      measurement range

      

      0—20mg/L

      

      measurement method

      

      4-aminoantipyrine spectrophotometric method

      

      detection limit

      

      0.1mg/L

      

      resolution

      

      zero point zero one

      

      accuracy

      

      ± 10% or ± 0.1mg/L (whichever is greater)

      

      repetitiveness

      

      ± 10% or ± 0.1mg/L (whichever is greater)

      

      zero drift

      

      ±0.05mg/L

      

      Span Drift

      

      ±10%

      

      measurement period

      

      The small measurement cycle is 20 minutes, and the digestion time can be set between 5-60 minutes

      

      sampling period

      

      Interval, hourly, and trigger modes can be adjusted

      

      calibration cycle

      

      Automatic calibration 1-99 days adjustable

      

      maintenance cycle

      

      Over 1 month, approximately 1 hour per session

      

      Human machine operation

      

      Touch screen display and command input

      

      Self checking protection

      

      Abnormal or power outage data not lost

      

      After abnormal reset or power outage, residual liquid will be automatically eliminated and work will resume

      

      data storage

      

      1 year of data storage

      

      input interface

      

      discrete signal

      

      output interface

      

      1 RS232 channel; Route 1 4-20mA

      

      working environment

      

      Suggested temperature: 15-25 ℃

      

      Operating Humidity

      

      ≤ 90% (non condensing)

      

      Power Supply and Power

      

      AC230±10%V;50—60Hz,5A

      

      size

      

      1500*550*450mm

      Water Quality Analyzer

      

    AfterSalesService :

    Key words:
    • Volatile phenol online analyzer