Color online analyzer cabinet colorimetric method for real-time monitoring of heavy metal color in water quality
Category:
Environmental Protection/Analytical instruments/Water quality online monitoring system
Model:
SZ-SD
Brand:
Jingcheng Instrument
model:
SZ-SD
Working Voltage:
220±20VAC
measurement accuracy:
±10%
structural style :
cabinet-type
Temperature control range:
5-40℃
Product Type:
Online instruments
Processing & Customization:
No
power:
one hundred
weight:
thirty-five
Scope of Application:
0-5mg/L
Place of Origin:
Qingdao
manufacturer:
Qingdao Jingcheng
Retail Price
40,000.00USD
重量
kg
- Product Description
-
model SZ-SD
Working Voltage 220±20VAC
measurement accuracy ±10%
structural style cabinet-type
Temperature control range 5-40℃
Product Type Online instruments
Processing & Customization No
power one hundred
weight thirty-five
Scope of Application 0-5mg/L
Place of Origin Qingdao
manufacturer Qingdao Jingcheng
Description :

Color online analyzer
cabinet-type
colorimetry
measurement method
Aluminum reagent colorimetric determination
measurement range
0-5mg/L
accuracy
<5% when>1mg/L; When < 1mg/L < ± 0.1mg/L
repetitiveness
<3% when>1mg/L; When < 1mg/L < ± 0.5mg/L
zero drift
±0.05mg/L
Span Drift
±10%
Fault free running time
≥ 720h/time
Measurement accuracy of water samples
±10%
measurement interval
Time measurement; Interval measurement
measurement period
about 15 minutes
Correction method
Timed calibration; manual correction
reagent consumption
Consume 4mg/L each time
internal sampling
Injection pump (replacement cycle: 1 year)
External sampling
Submersible pump; self-priming pump
data transmission
4-20mA;RS485; RS232; GPRS (customized)
ambient temperature
5-40℃
size
500*1650*321mm
weight
About 35KG
power supply
220±20VAC/50±0.5Hz
power
About 100W
measurement method
Platinum cobalt colorimetric method
measurement range
0-50mg/L
accuracy
<5%
repetitiveness
<3%
Span Drift
±10%
Fault free running time
≥ 720h/time
Measurement accuracy of water samples
±10%
measurement interval
Time measurement; Interval measurement
measurement period
about 20 minutes
Correction method
Timed calibration; manual correction
Water sample requirements
No freezing and no precipitation
reagent consumption
Consume 4mg/L each time
internal sampling
Injection pump (replacement cycle: 1 year)
External sampling
Submersible pump; self-priming pump
data transmission
4-20mA;RS485; RS232; GPRS (customized)
ambient temperature
5-40℃
size
550*810*350mm
weight
About 35KG
power supply
220±20VAC/50±0.5Hz
power
About 100W
Heavy metal monitoring device
Water Quality Tester
AfterSalesService :
Key words:- Color online analyzer
More Products