Online Total Cobalt Analyzer Cabinet style Nitroso Red Salt Colorimetric Method Heavy Metal Cobalt Ion Online Detector
Online Total Cobalt Analyzer Cabinet style Nitroso Red Salt Colorimetric Method Heavy Metal Cobalt Ion Online Detector

Online Total Cobalt Analyzer Cabinet style Nitroso Red Salt Colorimetric Method Heavy Metal Cobalt Ion Online Detector

Category:

Environmental Protection/Analytical instruments/Water quality online monitoring system

Model:

SZ-Co

Brand:

Jingcheng Instrument

model:

SZ-Co

Working Voltage:

AC230±10%V

measurement accuracy:

± 10% or ± 0.1mg/L (whichever is greater)

structural style :

cabinet-type

Temperature control range:

Suggested temperature: 15-25 ℃

Product Type:

Online instruments

Processing & Customization:

No

power:

50—60Hz,5A

Scope of Application:

0—0.5mg/L 0—1mg/L 0—5mg/L 0—10mg/L

Place of Origin:

Qingdao

manufacturer:

Qingdao Jingcheng

Retail Price

26,000.00USD


重量

kg

  • Product Description
  • model

    SZ-Co

    Working Voltage

    AC230±10%V

    measurement accuracy

    ± 10% or ± 0.1mg/L (whichever is greater)

    structural style

    cabinet-type

    Temperature control range

    Suggested temperature: 15-25 ℃

    Product Type

    Online instruments

    Processing & Customization

    No

    power

    50—60Hz,5A

    Scope of Application

    0—0.5mg/L 0—1mg/L 0—5mg/L 0—10mg/L

    Place of Origin

    Qingdao

    manufacturer

    Qingdao Jingcheng

    Description :

      Online Total Cobalt Analyzer

      Nitroso red salt colorimetric method

      1、 Product Overview of Online Total Cobalt Analyzer:

      Cobalt is a shiny steel gray metal that is relatively hard and brittle, with ferromagnetism. Its magnetism disappears when heated to 1150 ℃. The valence of cobalt is+2 and+3. It does not interact with water at room temperature and is also stable in humid air. When heated to above 300 ℃ in air, CoO is oxidized to form Co3O4, which burns at white heat. Fine metal cobalt powder produced by hydrogen reduction method can spontaneously combust in air to form cobalt oxide. Cobalt is an important raw material for the production of heat-resistant alloys, hard alloys, anti-corrosion alloys, magnetic alloys, and various cobalt salts.

      Water Quality Tester

      2、 Product principle of online total cobalt analyzer:

      Cobalt measurement is achieved through the analysis and detection device, control mechanism, as well as injection device, reaction device, constant temperature device, and mercury droplet control device respectively connected to the control mechanism. The injection device is connected to the reaction device through a pipeline and quantitatively sends various analysis samples into the reaction device. The constant temperature device is installed on the reaction device, and the mercury droplet control device is connected to the reaction device through a pipeline. The reaction device is connected to the analysis and detection device and transmits the measured data to the analysis and detection device. The utility model is a total cobalt online automatic monitoring device with simple and compact structure, low cost, easy operation, high measurement accuracy, fast measurement speed, and high degree of automation.

      Cobalt ion online analyzer

      3、 Technical parameters of online total cobalt analyzer:

      Specification Name

      

      Technical specifications and parameters

      

      measurement range

      

      0—0.5mg/L

      

      0—1mg/L

      

      0—5mg/L

      

      0—10mg/L

      

      measurement method

      

      Nitroso red salt colorimetric method

      

      detection limit

      

      0.01mg/L

      

      resolution

      

      zero point zero zero one

      

      accuracy

      

      ± 10% or ± 0.1mg/L (whichever is greater)

      

      repetitiveness

      

      ± 10% or ± 0.1mg/L (whichever is greater)

      

      zero drift

      

      ±0.05mg/L

      

      Span Drift

      

      ±10%

      

      measurement period

      

      The small measurement cycle is 20 minutes, and the digestion time can be set between 5-60 minutes

      

      sampling period

      

      Interval, hourly, and trigger modes can be adjusted

      

      calibration cycle

      

      Automatic calibration 1-99 days adjustable

      

      maintenance cycle

      

      Over 1 month, approximately 1 hour per session

      

      Human machine operation

      

      Touch screen display and command input

      

      Self checking protection

      

      Abnormal or power outage data not lost

      

      After abnormal reset or power outage, residual liquid will be automatically eliminated and work will resume

      

      data storage

      

      1 year of data storage

      

      output interface

      

      1 RS232 channel; Route 1 4-20mA

      

      working environment

      

      Suggested temperature: 15-25 ℃

      

      Operating Humidity

      

      ≤ 90% (non condensing)

      

      Power Supply and Power

      

      AC230±10%V;50—60Hz,5A

      

      size

      

      1500*550*450mm

      Heavy metal monitoring device

      

    AfterSalesService :

    Key words:
    • Online Total Cobalt Analyzer