Integrated UV principle flue gas analyzer UV differential flue gas comprehensive analyzer; Integrated&# 41;
Integrated UV principle flue gas analyzer UV differential flue gas comprehensive analyzer; Integrated&# 41;

Integrated UV principle flue gas analyzer UV differential flue gas comprehensive analyzer; Integrated&# 41;

Category:

Instrumentation/Gas analyzer/flue gas analyzer

Model:

GH-6060

Brand:

Jingcheng Instrument

model:

GH-6060

resolution:

1mg/m3

measurement object:

O2 SO2 NO NO2 NOX CO CO2 H2S

measurement range:

0-5000mg/m3, Other options are available for selection

power supply voltage:

two hundred and twenty

type:

UV smoke detector

display mode:

LED display

structural style :

Integrated host and detection gun

Processing & Customization:

yes

gas flow rate:

0-2000

Specifications:

UV flue gas analyzer

manufacturer:

Qingdao Jingcheng

Retail Price

65,000.00USD


重量

kg

  • Product Description
  • model

    GH-6060

    resolution

    1mg/m3

    measurement object

    O2 SO2 NO NO2 NOX CO CO2 H2S

    measurement range

    0-5000mg/m3, Other options are available for selection

    power supply voltage

    two hundred and twenty

    type

    UV smoke detector

    display mode

    LED display

    structural style

    Integrated host and detection gun

    Processing & Customization

    yes

    gas flow rate

    0-2000

    Specifications

    UV flue gas analyzer

    manufacturer

    Qingdao Jingcheng

    Description :

      2、 Purpose:

      Jingcheng Instrument adopts DOAS ultraviolet differential absorption spectroscopy and electrochemical technology to measure gas components such as SO2/NO/NOz in fixed pollution source exhaust pipes using hot and wet methods, and O2/CO/CO2/H2S using constant potential electrolysis method. It is particularly suitable for measuring harmful gas components in high CO, high humidity, low SO2, and ammonia escape flue gas. It has the advantages of high measurement accuracy, strong reliability, fast response time, and long service life. The on-site humidity of the instrument is high, especially the interference caused by high concentration of sulfur dioxide. Conventional instruments cannot detect sulfur dioxide concentration, so this instrument can be used.

      HJ/44-2015 "Technical Requirements and Calibration Methods for Portable UV Absorption Smoke Measurement Systems"

      DB37/T 2705-2015 "Determination of Sulfur Dioxide in Waste Gas from Fixed Pollution Sources in Shandong Province by UV Absorption Method"

      DB37/T 2704-2015 "Determination of nitrogen oxides in exhaust gas from fixed pollution sources in Shandong Province by UV absorption method"

      HJ 1131-2020 "Portable UV Absorption Method for Determination of Fixed Source Waste Gas and Sulfur Dioxide"

      HJ 1132-2020 "Portable UV Absorption Method for Determination of Fixed Source Waste Gas and Nitrogen Oxides"

      4、 Performance characteristics

      The integrated structure of the dust filtering heating sampling tube and the main unit effectively reduces the adsorption of SO2 by condensed water in the pipeline and improves measurement accuracy

      5.0-inch wide temperature color touch screen, with touch screen APP、 Network multi screen collaborative operation function

      The ultraviolet differential absorption spectroscopy (DOAS) method is currently the analytical tool for gases such as SO2, NO, NO2, NH3, etc. The hot and wet methods directly measure SO2, NO, NO2 in flue gas, and the measurement accuracy is completely unaffected by moisture and dust. It is particularly suitable for high CO, high humidity, low SO2, and ammonia escape pipelines, and has the advantages of low detection limit and small temperature drift

      Mold based optical path design improves instrument stability and reduces the impact of environmental temperature changes on monitoring results

      ◆ Set parameters for automatic memory, prioritize use on the next startup, and achieve key sampling

      Real time display of monitoring data minute average, especially suitable for CEMS comparison acceptance calibration

      The data storage capacity can reach millions of sets, which can be directly printed and exported from a USB drive

      ◆ Multi level optoelectronic isolation, multi CPU fault-tolerant structure, overcoming electrostatic interference, ensuring safe and reliable operation of the instrument

      ◆ Fault self checking function, convenient for users to detect, maintain, and use

      ◆ Adopting industrial grade sealed box, waterproof, dustproof, collision resistant, small in size, light in weight, and easy to carry

      5、 Technical parameters:

      Main parameters

      

      parameter range

      

      resolution

      

      accuracy

      

      Smoke temperature

      

      (0~500) ° C (expandable)

      

      0.1℃

      

      ≤±3.0℃

      

      static pressure

      

      (- 35 ~ +35) kPa

      

      0.01kPa

      

      ≤±1.0%FS

      

      dynamic pressure

      

      (0~ 2500) Pa

      

      1Pa

      

      ≤±1.0%FS

      

      total pressure

      

      (- 30~+30) kPa

      

      0.01kPa

      

      ≤±1.0%FS

      

      flow velocity

      

      (1 ~ 45)m/s

      

      0.1m/s

      

      ≤±5%

      

      humidity ratio

      

      (0~ 60) %

      

      0.1%

      

      ≤±2%

      

      sampling flow

      

      0.5 L/min

      

      0.1L/min

      

      ≤±5%

      

      atmospheric pressure

      

      (50~ 130) kPa

      

      0.01kPa

      

      ≤±0.50kPa

      

      Excess air coefficient

      

      1~ 99.99

      

      zero point zero one

      

      ≤±2.5%

      

      data storage

      

      &>1000000 groups

      

      

      

      Operating Temperature

      

      (- 20~+50)°C

      

      

      

      working power supply

      

      AC 220V+10%,50HZ

      

      

      

      host size

      

      (Length 1200x Width 130x Height 180) mm

      

      

      

      host weight

      

      About 6kg

      

      

      

      power consumption

      

      <100w

      

      

      

      02 (electrochemistry)

      

      (0-30 )%

      

      0.1%

      

      Indication error: ≤± 5%

      Repeatability: ≤ 2.0%

      Response time: ≤ 90s

      Stability: Within 1 hour, the displayed value changes by less than 5%

      

      SO2 (UV)

      

      Low range (0~572) mg/m3

      

      0.1mg/m3

      

      SO2 (UV)

      

      High range (0~5720) mg/m3

      

      0.1mg/m3

      

      NO (UV)

      

      Low range (0~268) mg/m3

      

      0.1mg/m3

      

      NO (UV)

      

      High range (0~1340) mg/m3

      

      1mg/m3

      

      NO2 (UV)

      

      (0~ 1025) mg/m3

      

      1mg/m3

      

      NH3 (optional)

      

      (0~ 380). mg/m3

      

      1mg/m3

      

      H25 "(optional)

      

      ( 0~300) mg/m3

      

      1mg/m3

      

      C0 (optional)

      

      ( 0~ 5000 ) mg/m3

      

      1mg/m3

      

      CO2 (optional 2)

      

      (0~30)%

      

      0.01%

      

      Portable flue gas analyzer, purple gas analyzer, portable integrated ultraviolet ammonia analyzer, ammonia detector, flue gas sulfur dioxide detector, flue gas nitrogen oxide detector

    AfterSalesService :

    Key words:
    • Integrated UV principle flue gas analyzer