Integrated UV principle flue gas analyzer UV differential flue gas comprehensive analyzer; Integrated 41;
Category:
Instrumentation/Gas analyzer/flue gas analyzer
Model:
GH-6060
Brand:
Jingcheng Instrument
model:
GH-6060
resolution:
1mg/m3
measurement object:
O2 SO2 NO NO2 NOX CO CO2 H2S
measurement range:
0-5000mg/m3, Other options are available for selection
power supply voltage:
two hundred and twenty
type:
UV smoke detector
display mode:
LED display
structural style :
Integrated host and detection gun
Processing & Customization:
yes
gas flow rate:
0-2000
Specifications:
UV flue gas analyzer
manufacturer:
Qingdao Jingcheng
Retail Price
65,000.00USD
重量
kg
- Product Description
-
model GH-6060
resolution 1mg/m3
measurement object O2 SO2 NO NO2 NOX CO CO2 H2S
measurement range 0-5000mg/m3, Other options are available for selection
power supply voltage two hundred and twenty
type UV smoke detector
display mode LED display
structural style Integrated host and detection gun
Processing & Customization yes
gas flow rate 0-2000
Specifications UV flue gas analyzer
manufacturer Qingdao Jingcheng
Description :
2、 Purpose:
Jingcheng Instrument adopts DOAS ultraviolet differential absorption spectroscopy and electrochemical technology to measure gas components such as SO2/NO/NOz in fixed pollution source exhaust pipes using hot and wet methods, and O2/CO/CO2/H2S using constant potential electrolysis method. It is particularly suitable for measuring harmful gas components in high CO, high humidity, low SO2, and ammonia escape flue gas. It has the advantages of high measurement accuracy, strong reliability, fast response time, and long service life. The on-site humidity of the instrument is high, especially the interference caused by high concentration of sulfur dioxide. Conventional instruments cannot detect sulfur dioxide concentration, so this instrument can be used.
HJ/44-2015 "Technical Requirements and Calibration Methods for Portable UV Absorption Smoke Measurement Systems"
DB37/T 2705-2015 "Determination of Sulfur Dioxide in Waste Gas from Fixed Pollution Sources in Shandong Province by UV Absorption Method"
DB37/T 2704-2015 "Determination of nitrogen oxides in exhaust gas from fixed pollution sources in Shandong Province by UV absorption method"
HJ 1131-2020 "Portable UV Absorption Method for Determination of Fixed Source Waste Gas and Sulfur Dioxide"
HJ 1132-2020 "Portable UV Absorption Method for Determination of Fixed Source Waste Gas and Nitrogen Oxides"
4、 Performance characteristics
The integrated structure of the dust filtering heating sampling tube and the main unit effectively reduces the adsorption of SO2 by condensed water in the pipeline and improves measurement accuracy
5.0-inch wide temperature color touch screen, with touch screen APP、 Network multi screen collaborative operation function
The ultraviolet differential absorption spectroscopy (DOAS) method is currently the analytical tool for gases such as SO2, NO, NO2, NH3, etc. The hot and wet methods directly measure SO2, NO, NO2 in flue gas, and the measurement accuracy is completely unaffected by moisture and dust. It is particularly suitable for high CO, high humidity, low SO2, and ammonia escape pipelines, and has the advantages of low detection limit and small temperature drift
Mold based optical path design improves instrument stability and reduces the impact of environmental temperature changes on monitoring results
◆ Set parameters for automatic memory, prioritize use on the next startup, and achieve key sampling
Real time display of monitoring data minute average, especially suitable for CEMS comparison acceptance calibration
The data storage capacity can reach millions of sets, which can be directly printed and exported from a USB drive
◆ Multi level optoelectronic isolation, multi CPU fault-tolerant structure, overcoming electrostatic interference, ensuring safe and reliable operation of the instrument
◆ Fault self checking function, convenient for users to detect, maintain, and use
◆ Adopting industrial grade sealed box, waterproof, dustproof, collision resistant, small in size, light in weight, and easy to carry
5、 Technical parameters:
Main parameters
parameter range
resolution
accuracy
Smoke temperature
(0~500) ° C (expandable)
0.1℃
≤±3.0℃
static pressure
(- 35 ~ +35) kPa
0.01kPa
≤±1.0%FS
dynamic pressure
(0~ 2500) Pa
1Pa
≤±1.0%FS
total pressure
(- 30~+30) kPa
0.01kPa
≤±1.0%FS
flow velocity
(1 ~ 45)m/s
0.1m/s
≤±5%
humidity ratio
(0~ 60) %
0.1%
≤±2%
sampling flow
0.5 L/min
0.1L/min
≤±5%
atmospheric pressure
(50~ 130) kPa
0.01kPa
≤±0.50kPa
Excess air coefficient
1~ 99.99
zero point zero one
≤±2.5%
data storage
&>1000000 groups
Operating Temperature
(- 20~+50)°C
working power supply
AC 220V+10%,50HZ
host size
(Length 1200x Width 130x Height 180) mm
host weight
About 6kg
power consumption
<100w
02 (electrochemistry)
(0-30 )%
0.1%
Indication error: ≤± 5%
Repeatability: ≤ 2.0%
Response time: ≤ 90s
Stability: Within 1 hour, the displayed value changes by less than 5%
SO2 (UV)
Low range (0~572) mg/m3
0.1mg/m3
SO2 (UV)
High range (0~5720) mg/m3
0.1mg/m3
NO (UV)
Low range (0~268) mg/m3
0.1mg/m3
NO (UV)
High range (0~1340) mg/m3
1mg/m3
NO2 (UV)
(0~ 1025) mg/m3
1mg/m3
NH3 (optional)
(0~ 380). mg/m3
1mg/m3
H25 "(optional)
( 0~300) mg/m3
1mg/m3
C0 (optional)
( 0~ 5000 ) mg/m3
1mg/m3
CO2 (optional 2)
(0~30)%
0.01%
Portable flue gas analyzer, purple gas analyzer, portable integrated ultraviolet ammonia analyzer, ammonia detector, flue gas sulfur dioxide detector, flue gas nitrogen oxide detector
AfterSalesService :
Key words:- Integrated UV principle flue gas analyzer