Handheld ship exhaust analyzer UV portable smoke analyzer
Handheld ship exhaust analyzer UV portable smoke analyzer

Handheld ship exhaust analyzer UV portable smoke analyzer

Category:

Instrumentation/Gas analyzer/flue gas analyzer

Model:

JH-6060

Brand:

Jingcheng Instrument

model:

JH-6060

resolution:

1mg/m3

measurement object:

O2 SO2 NO NO2 NOX CO CO2 H2S

measurement range:

0-5000mg/m3, Other options are available for selection

power supply voltage:

two hundred and twenty

type:

Smoke detector

display mode:

LED display

structural style :

Integrated host and detection gun

Processing & Customization:

yes

gas flow rate:

0-2000

Specifications:

Portable smoke analyzer

manufacturer:

Qingdao Jingcheng

Retail Price

60,000.00USD


重量

kg

  • Product Description
  • model

    JH-6060

    resolution

    1mg/m3

    measurement object

    O2 SO2 NO NO2 NOX CO CO2 H2S

    measurement range

    0-5000mg/m3, Other options are available for selection

    power supply voltage

    two hundred and twenty

    type

    Smoke detector

    display mode

    LED display

    structural style

    Integrated host and detection gun

    Processing & Customization

    yes

    gas flow rate

    0-2000

    Specifications

    Portable smoke analyzer

    manufacturer

    Qingdao Jingcheng

    Description :

      Portable ship exhaust gas analyzer, portable ultraviolet absorption method smoke comprehensive analyzer, integrated ultraviolet absorbable absorption method pollution source gas detector, portable detection system for ship exhaust gas

      4Performance Characteristics

      The integrated structure of the dust filtering heating sampling tube and the main unit effectively reduces the adsorption of SO2 by condensed water in the pipeline and improves measurement accuracy

      5.0-inch wide temperature color touch screen, with touch screen APP、 Network multi screen collaborative operation function

      The ultraviolet differential absorption spectroscopy (DOAS) method is currently the analytical tool for gases such as SO2, NO, NO2, NH3, etc. The hot and wet methods directly measure SO2, NO, NO2 in flue gas, and the measurement accuracy is completely unaffected by moisture and dust. It is particularly suitable for high CO, high humidity, low SO2, and ammonia escape pipelines, and has the advantages of low detection limit and small temperature drift

      Mold based optical path design improves instrument stability and reduces the impact of environmental temperature changes on monitoring results

      ◆ Set parameters for automatic memory, prioritize use on the next startup, and achieve key sampling

      Real time display of monitoring data minute average, especially suitable for CEMS comparison acceptance calibration

      The data storage capacity can reach millions of sets, which can be directly printed and exported from a USB drive

      ◆ Multi level optoelectronic isolation, multi CPU fault-tolerant structure, overcoming electrostatic interference, ensuring safe and reliable operation of the instrument

      ◆ Fault self checking function, convenient for users to detect, maintain, and use

      ◆ Adopting industrial grade sealed box, waterproof, dustproof, collision resistant, small in size, light in weight, and easy to carry

      5、 Technical parameters:

      Main parameters

      

      parameter range

      

      resolution

      

      accuracy

      

      Smoke temperature

      

      (0~500) ° C (expandable)

      

      0.1℃

      

      ≤±3.0℃

      

      static pressure

      

      (- 35 ~ +35) kPa

      

      0.01kPa

      

      ≤±1.0%FS

      

      dynamic pressure

      

      (0~ 2500) Pa

      

      1Pa

      

      ≤±1.0%FS

      

      total pressure

      

      (- 30~+30) kPa

      

      0.01kPa

      

      ≤±1.0%FS

      

      flow velocity

      

      (1 ~ 45)m/s

      

      0.1m/s

      

      ≤±5%

      

      humidity ratio

      

      (0~ 60) %

      

      0.1%

      

      ≤±2%

      

      sampling flow

      

      0.5 L/min

      

      0.1L/min

      

      ≤±5%

      

      atmospheric pressure

      

      (50~ 130) kPa

      

      0.01kPa

      

      ≤±0.50kPa

      

      Excess air coefficient

      

      1~ 99.99

      

      zero point zero one

      

      ≤±2.5%

      

      data storage

      

      &>1000000 groups

      

      

      

      Operating Temperature

      

      (- 20~+50)°C

      

      

      

      working power supply

      

      AC 220V+10%,50HZ

      

      

      

      host size

      

      (Length 1200x Width 130x Height 180) mm

      

      

      

      host weight

      

      About 6kg

      

      

      

      power consumption

      

      <100w

      

      

      

      02 (electrochemistry)

      

      (0-30 )%

      

      0.1%

      

      Indication error: ≤± 5%

      Repeatability: ≤ 2.0%

      Response time: ≤ 90s

      Stability: Within 1 hour, the displayed value changes by less than 5%

      

      SO2 (UV)

      

      Low range (0~572) mg/m3

      

      0.1mg/m3

      

      SO2 (UV)

      

      High range (0~5720) mg/m3

      

      0.1mg/m3

      

      NO (UV)

      

      Low range (0~268) mg/m3

      

      0.1mg/m3

      

      NO (UV)

      

      High range (0~1340) mg/m3

      

      1mg/m3

      

      NO2 (UV)

      

      (0~ 1025) mg/m3

      

      1mg/m3

      

      NH3 (optional)

      

      (0~ 380). mg/m3

      

      1mg/m3

      

      H25 "(optional)

      

      ( 0~300) mg/m3

      

      1mg/m3

      

      C0 (optional)

      

      ( 0~ 5000 ) mg/m3

      

      1mg/m3

      

      CO2 (optional 2)

      

      (0~30)%

      

      0.01%

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

    AfterSalesService :

    Key words:
    • Handheld ship exhaust analyzer