The air fluoride sampler can collect fluoride tsp/pm10/pm2.5
The air fluoride sampler can collect fluoride tsp/pm10/pm2.5

The air fluoride sampler can collect fluoride tsp/pm10/pm2.5

Category:

Instrumentation/Analytical instruments/sampler

Model:

JH-120K

Brand:

sincerity

brand:

sincerity

model:

JH-120K

Installation method:

portable

display mode:

LED display

Sampling flow range:

16.7-50

power supply voltage:

220 or 12

ambient temperature:

10~35℃

ambient humidity:

≤95%

Processing & Customization:

yes

Sampling flow accuracy:

≤±2.5%

sampling time:

four hundred and eighty

noise:

one

weight:

three

Place of Origin:

Qingdao, Shandong

manufacturer:

Qingdao Jingcheng Instrument Co., Ltd

Retail Price

8,000.00USD


重量

kg

  • Product Description
  • brand

    sincerity

    model

    JH-120K

    Installation method

    portable

    display mode

    LED display

    Sampling flow range

    16.7-50

    power supply voltage

    220 or 12

    ambient temperature

    10~35℃

    ambient humidity

    ≤95%

    Processing & Customization

    yes

    Sampling flow accuracy

    ≤±2.5%

    sampling time

    four hundred and eighty

    noise

    one

    weight

    three

    Place of Origin

    Qingdao, Shandong

    manufacturer

    Qingdao Jingcheng Instrument Co., Ltd

    Description :

      Fluoride sampler, 16.7L/min fluoride sampler, double-layer filter membrane fluoride sampler, filter membrane sampler, heavy metal sampler, atmospheric heavy metal sampler, atmospheric fluoride sampler

      1、 JH-120K air fluoride sampler can collect fluoride tsp/pm10/pm2.5

      Suitable for the determination of gaseous and particulate fluorides in ambient air,. The acetic acid fiber microporous membrane (pore size 5 μ m, diameter 90mm) impregnated with dipotassium dihydrogen phosphate was used. When the sampling flow rate was 50L/min and the sampling time was 1h, the detection limit of the method was 0.5 μ g/m3, and the lower limit of determination was 2.0 μ g/m3; When the sampling flow rate is 16.7L/min and the sampling time is 24h, the detection limit of the method is 0.06 μ g/m3, and the lower limit of determination is 0.24 μ g/m3.

      2、 JH-120K environmental air fluoride sampler meets the standard

      JJG 943-2011 "Total Suspended Particle Sampler"

      HJ/T194-2005 Technical Specification for Manual Monitoring of Environmental Air Quality

      HJ93-2013 "Technical Requirements and Detection Methods for Particulate Matter (PM10 and PM2.5) Samplers in Environmental Air"

      HJ955-2018 "Determination of Fluoride in Environmental Air - Membrane Sampling/Fluoride Ion Selective Electrode Method"

      HJ 194-2017 Technical Specification for Manual Monitoring of Environmental Air Quality

      HJ 618-2011 "Determination of Weight for PM10 and PM2.5 in Environmental Air"

      3、 Scope of application of JH-120K ambient air fluoride sampler

      Collecting ambient air fluoride can also be extended to measure TSP, PM10, and PM2.5.

      Suitable for the determination of gaseous and particulate fluorides in ambient air,. The acetic acid fiber microporous membrane (pore size 5 μ m, diameter 90mm) impregnated with dipotassium dihydrogen phosphate was used. When the sampling flow rate was 50L/min and the sampling time was 1h, the detection limit of the method was 0.5 μ g/m3, and the lower limit of determination was 2.0 μ g/m3; When the sampling flow rate is 16.7L/min and the sampling time is 24h, the detection limit of the method is 0.06 μ g/m3, and the lower limit of determination is 0.24 μ g/m3.

      4、 Technical parameters of JH-120K ambient air fluoride sampler

    Main parameters parameter range resolution accuracy
    sampling flow (10~100)L/min 0.1L/min Better than ± 2.0%
    Z large sampling volume 999999.9L 0.1L Better than ± 2.0%
    sampling time 1min~99h59min 1s Better than ± 0.1%
    Environmental atmospheric pressure (50~130)kPa 0.01kPa Better than ± 0.5kPa
    load capacity When the flow rate is 50L/min, the load capacity is greater than 30kPa
    Working Voltage AC220V ± 10% 50Hz or optional portable AC/DC power supply
    noise <65dB(A)
    power consumption <100W

      5、 Performance characteristics of JH-120K ambient air fluoride sampler

      1. Adopting a wide temperature LCD display screen, Chinese menu display, illustrated text, convenient operation.

      2. Adopting a volumetric imported brushless blade pump with a flow range of (10-100) L/min. At a flow rate of 50L/min, the load capacity is greater than 30kPa, with a daily sampling rate of 16.67L/min; Sampling at an average of 50L/min with two functions.

      3. The sampling head can hold a 90mm filter membrane (effective diameter 80mm), equipped with two layers of stainless steel support filter membrane mesh pads, with a 2mm to 3mm interval between the two layers of mesh pads.

      4. Using electronic flow meters and flow compensation systems, automatic measurement of temperature, atmospheric pressure, pre gauge temperature, pre gauge pressure and other parameters, and automatic calculation of cumulative volume.

      5. When conducting hourly mean measurement, collect at a flow rate of 50L/min, with a load capacity greater than 30kPa (greater than the standard requirement to overcome a pressure load of 20kPa), and sample for at least 45 minutes; When measuring the 24-hour mean, collect at a flow rate of 16.7L/min for at least 20 hours.

      6. It has the functions of air path blockage and low flow protection. If the set flow rate is not reached within a certain period of time during sampling, the instrument will enter automatic protection mode.

      7. The various parameters of the instrument can be calibrated online directly through the keyboard. Password must be entered for instrument maintenance and calibration, and it has permission management function to ensure the safety of all parameters of the instrument.

      8. Adopting waterproof structure design, it can prevent rain and snow invasion during field work.

      9. Equipped with a real-time clock, the sampling data is automatically memorized and prioritized for use the next time it is turned on, achieving one click sampling.

      10. Automatically store monitoring data, can be copied and printed with an external printer or USB flash drive.

      11. The sampling head is made of aluminum alloy material and has undergone oxidation treatment to resist electrostatic adsorption.

      12. The factory standard fluoride dual membrane sampling head can sample gaseous and particulate fluorides in the ambient air.

      Fluoride sampler

    AfterSalesService :

    Key words:
    • Air fluoride sampler