Slit collection method 100L/min portable planktonic bacteria sampler
Category:
Instrumentation/Analytical instruments/sampler
Model:
JVQ-IV
Brand:
sincerity
brand:
sincerity
model:
JVQ-IV
Installation method:
portable
display mode:
LED display
Sampling flow range:
one hundred
power supply voltage:
twelve
ambient temperature:
-20-35
ambient humidity:
40%RH
Processing & Customization:
yes
Sampling flow accuracy:
zero point one
sampling time:
nine thousand nine hundred and ninety-nine
noise:
one
weight:
zero point five
Place of Origin:
Qingdao, Shandong
manufacturer:
Qingdao Jingcheng Instrument Co., Ltd
Retail Price
5,000.00USD
重量
kg
- Product Description
-
brand sincerity
model JVQ-IV
Installation method portable
display mode LED display
Sampling flow range one hundred
power supply voltage twelve
ambient temperature -20-35
ambient humidity 40%RH
Processing & Customization yes
Sampling flow accuracy zero point one
sampling time nine thousand nine hundred and ninety-nine
noise one
weight zero point five
Place of Origin Qingdao, Shandong
manufacturer Qingdao Jingcheng Instrument Co., Ltd
Description :

1JYQ-IVFloating bacteria samplerProduct Overview:
Based on the principle of particle impact and referring to the SAT type planktonic bacteria sampler in the United States, we have developed the QT type gap type planktonic bacteria sampler, which can directly measure the number of bacteria in 1 cubic meter of gas, effectively cooperating with the implementation of China's "GMP" specifications. The product has a reasonable structure and high technical performance indicators. The sampling flow rate reaches 100L/min, and the overall level of the instrument reaches the product level, filling the gap of high flow slit type planktonic bacteria sampler. The application of the method of reducing bacterial count cannot directly determine the bacterial count per unit volume, which is no longer suitable for the requirements of China's "GMP" specifications.
The JYQ-IV airborne dust and bacteria sampler is a porous inhalation dust and bacteria sampler. It is designed based on the principle of particle impact and the theory of constant velocity sampling. Sampling is direct, and the wind speed at the sampling port is basically the same as that in the clean room, which can more accurately reflect the microbial concentration in the clean room. During sampling, the air carrying dust bacteria passes through the micropores at high speed and is impacted on the surface of the agar in the culture dish; These live microorganisms undergo dynamic rehydration during the cultivation process, growing at high speeds to obtain faster results.
This instrument has a unique and innovative structure, divided into two parts: the upper part is the collection port, sampling seat, and air pump, and the lower part is the controller and battery. The sampling port and housing are made of aviation aluminum, with a closed cell surface treatment for easy sterilization and disinfection before use. This instrument has powerful functions, large sampling volume, stable performance, and easy operation. It is an ideal floating dust bacteria concentration sampling instrument for various pharmaceutical factories, hospitals, biological products, food processing, public places, and other testing departments.
IIJYQ-IVFloating bacteria samplerKey Features:
1. The collection port has countless micropores, reducing the overlap of dust and bacteria and minimizing microbial counting errors.
2. Programmable, sample size can be set arbitrarily from 0.01-6.0 cubic meters.
3. LCD displays parameters such as sampling amount and sampling time.
4. It can store parameters such as sampling volume and sampling time in groups, and can store 256 sets of data.
5. Unique design and easy to use.
6. Replacing the culture dish is simple. Simply remove the collection port to replace the culture dish (using a standard universal culture dish with a diameter of 90 * 15)
III JYQ-IVTechnical parameters of planktonic bacteria sampler:
Sampling flow rate: 100L/min
Sampling port flow rate: 0.4 meters per second, which is basically the same as the speed in the clean room (constant velocity sampling)
Sampling period: arbitrarily set
Specification of culture dish: Φ 90 × 15mm
Working environment: Temperature range of 10-35 ℃, relative temperature range of 20-75% RH
Dimensions: Φ 120 x 300mm
Power supply: AC/DC dual-use, rechargeable battery DC6V, can work continuously for 4 hours after being fully charged
Power consumption: 20W
Weight: 2kg


AfterSalesService :
Key words:- Floating bacteria sampler
More Products