Carbon monoxide analyzer non dispersive infrared method
Carbon monoxide analyzer non dispersive infrared method

Carbon monoxide analyzer non dispersive infrared method

Category:

Instrumentation/Gas analyzer/Carbon monoxide detector

Model:

LB-3021A

Brand:

Qingdao Road Expo

model:

LB-3021A

type:

portable

measurement range:

0~0.500%

measurement object:

CO CO2

measurement accuracy:

0.1×10-6CO;0.001%CO2

resolution:

0.1×10-6CO;0.001%CO2

power supply:

Built in lithium battery, dual-use for AC and DC, can be manually switched freely

voltage:

two hundred and twenty

Processing & Customization:

yes

weight:

About 6

manufacturer:

Qingdao Road Expo

Retail Price

13,600.00USD


重量

kg

  • Product Description
  • model

    LB-3021A

    type

    portable

    measurement range

    0~0.500%

    measurement object

    CO CO2

    measurement accuracy

    0.1×10-6CO;0.001%CO2

    resolution

    0.1×10-6CO;0.001%CO2

    power supply

    Built in lithium battery, dual-use for AC and DC, can be manually switched freely

    voltage

    two hundred and twenty

    Processing & Customization

    yes

    weight

    About 6

    manufacturer

    Qingdao Road Expo

    Description :

      The main technical indicators of the intelligent infrared carbon monoxide and carbon dioxide analyzer meet the technical requirements of the national second level instrument and can obtain the second level calibration certificate from the China Institute of Metrology.

      The intelligent infrared carbon monoxide and carbon dioxide analyzer is suitable for detecting and monitoring carbon monoxide and carbon dioxide in public places, health supervision, environmental monitoring and other occasions.

      2、 Execution standards

      JJG635-2011 Infrared Gas Analyzer for Carbon Monoxide and Carbon Dioxide

      HJ965-2018 "Automatic determination of carbon monoxide in ambient air using non dispersive infrared method"

      GB/T18204.2-2014 "Methods for hygiene inspection in public places - Part 2: Chemical pollutants"

      GBZ/T 300.37-2017 "Determination of Toxic Substances in Workplace Air Part 37: Carbon Monoxide and Carbon Dioxide"

      GB 9801-1988 "Air quality - Determination of carbon monoxide - Non dispersive infrared method"

      Used for gas detection in public places, health supervision, environmental monitoring, etc., it successfully solves the accuracy guarantee and compensation in high and low temperature measurement, with high measurement accuracy!!

      4、 Technical parameters:

      1. Detection principle: Non dispersive infrared gas analysis method/Non dispersive infrared method (NDIR)

      2. Detecting gases: carbon monoxide (CO), carbon monoxide (CO2) in the air

      3. Detection method: Built in pump suction

      4. Measurement range: 0~50.0 × 10-6CO, 0~0.500% CO2 or 0~200.0 × 10-6CO, 0~1.000% CO2

      5. Temperature: -20 ∽ 60 ℃

      6. Humidity: 10-95% RH

      7. Automatic conversion of concentration display between ppm and mg/m3

      8. Resolution: 0.1 × 10-6CO; 0.001% CO2

      9. Display screen: 7-inch capacitive touch screen

      10. Can store 10000 sets of measurement data

      11. Zero point automatic correction technology

      12. Indication error: 13. Repeatability: 14. Range drift: 15. Zero drift: 16. Carbon monoxide interference: 1250mg/m3CO ≤± 0.3% F · S

      17. Response time: 18. Instrument noise: 19. Preheating time: 30 minutes

      20. Flow range: (0.5-2.0) L/min

      21. Output interface: USB output, equipped with data transmission software

      22. It has sound and light alarm functions, and the alarm limit can be set

      23. Battery working time: continuous operation for more than 4 hours

      24. Power supply: Equipped with a built-in lithium battery, it can be used for both AC and DC, and can be manually switched freely

      25. Dimensions: 255 × 165 × 340 (mm)

      26. Whole machine weight: approximately 6.0kg

    AfterSalesService :

    Key words:
    • Carbon monoxide analyzer