Biological safety cabinet detector LB-2116 detects whether there is a leak inside the biological safety cabinet
Biological safety cabinet detector LB-2116 detects whether there is a leak inside the biological safety cabinet

Biological safety cabinet detector LB-2116 detects whether there is a leak inside the biological safety cabinet

Category:

Instrumentation/Environmental testing instruments/Other environmental testing instruments

Model:

LB-2116

Brand:

Qingdao Lubo Jianye Environmental Protection Techn

model:

LB-2116

measurement object:

Check for leaks inside the biosafety cabinet

measurement range:

100L/min

Processing & Customization:

No

Overall dimensions:

( 450×400×750) mm

weight:

About 25kg

Place of Origin:

Qingdao

manufacturer:

Qingdao Road Expo

Retail Price

111,112.00USD


重量

kg

  • Product Description
  • model

    LB-2116

    measurement object

    Check for leaks inside the biosafety cabinet

    measurement range

    100L/min

    Processing & Customization

    No

    Overall dimensions

    ( 450×400×750) mm

    weight

    About 25kg

    Place of Origin

    Qingdao

    manufacturer

    Qingdao Road Expo

    Description :

      Biosafety Cabinet Detectorworking principle

      Simulate the pollution gas or escape gas generated inside the safety cabinet with potassium iodide, and use an aerosol generator to transport potassium iodide solution at specific locations inside or outside the biological safety cabinet, generating mist like potassium iodide droplets to form challenge gas

      Sol, using the principle of centripetal force, captures potassium iodide aerosols escaping through the window using an air sampler.

      After sampling, remove the filter membrane from the sampler and place it in a culture dish containing the solution. The potassium iodide droplets on the filter membrane will unfold, forming clear and visible brown dots. Evaluate the protective capability of the safety cabinet by counting the number of dots on the filter membrane.

      Background detection: No need to start the aerosol generator, directly detect the environment of the biosafety cabinet;

      Personnel protection: Check whether KI aerosols inside the biosafety cabinet leak to the outside;

      Product protection: Detect whether KI aerosols outside the biosafety cabinet have entered the interior;

      Cross infection: Has the aerosol contamination between devices inside the biosafety cabinet been minimized.

    AfterSalesService :

    Key words:
    • Biosafety Cabinet Detector