Manufacturer of direct reading oil fume detector
Manufacturer of direct reading oil fume detector

Manufacturer of direct reading oil fume detector

Category:

Instrumentation/Environmental testing instruments/Other environmental testing instruments

Model:

LB-7025B

Brand:

Qingdao Lubo Jianye Environmental Protection Techn

model:

LB-7025B

measurement object:

cooking fumes

measurement range:

(0~60.0)mg/m3

measurement accuracy:

±0.2mg/m3

Processing & Customization:

yes

Overall dimensions:

Length x Width x Height (114 * 110 * 245)

weight:

About 2.5kg

Place of Origin:

Qingdao

manufacturer:

Qingdao Road Expo

Retail Price

26,566.00USD


重量

kg

  • Product Description
  • model

    LB-7025B

    measurement object

    cooking fumes

    measurement range

    (0~60.0)mg/m3

    measurement accuracy

    ±0.2mg/m3

    Processing & Customization

    yes

    Overall dimensions

    Length x Width x Height (114 * 110 * 245)

    weight

    About 2.5kg

    Place of Origin

    Qingdao

    manufacturer

    Qingdao Road Expo

    Description :

      In daily life, we cannot do without three meals and the kitchen. The kitchen is the place where oil fumes accumulate the most. People who often appear in the kitchen, especially chefs and housewives, inevitably come into contact with oil fumes. Oil fume is a harmless thing that is not welcomed anywhere, but it can penetrate everywhere. Do you know what harm kitchen oil fume can bring to the human body?

      The kitchen is the most serious source of air pollution in households, and many housewives and mothers do not pay attention to it. The main sources are cooking fumes and liquefied gases such as carbon monoxide, carbon dioxide, nitrogen oxides, etc.

      Oil fume contains approximately 300 harmful substances, DNP, etc., including lung AI causing substances such as "benzo [a] pyrene". Prolonged inhalation of oil fume can lead to tissue damage in the human body.

    Below, Qingdao Lubo manufacturer recommends a direct reading oil fume detector for detectionMonitoring of oil fume concentration, particulate matter, and non methane total hydrocarbonsManufacturer contact person: Fu Yajian

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

      

    Product Introduction

      The LB-7025B portable oil fume detector is a new generation of intelligent rapid oil fume detector carefully developed by our company. Suitable for detecting parameters such as cooking oil fume concentration, particulate matter, and non methane total hydrocarbons emitted by restaurants, hotels, government canteens, and other units. Unlike the previous method of collecting samples on-site and bringing them back to the laboratory for analysis, this detector can complete the entire process of oil fume concentration detection, data processing, analysis display, and record transmission on site. The LB-7025B portable oil fume detector is sensitive to oil fume, has high measurement accuracy, stable and reliable measurement data, and is easy to carry.

    Scope of application

      Environmental monitoring and supervision departments: Environmental inspection and acceptance of catering units, routine oil fume testing, on-site handling of oil fume disturbance complaints, oil fume investigation of catering units, testing of various non edible oil fumes (such as asphalt smoke, pine cigarettes, etc.).

      B City Management Administrative Law Enforcement (Urban Management) Department: Food and Beverage Industry Oil Fume Pollution Remediation, On site Administrative Penalties.

      C universities and research institutes: research on oil fume related topics.

      Monitoring of oil fume concentration, particulate matter, and non methane total hydrocarbons in D industrial oil fume.

    reference standard

      GB16157-1996 "Determination of particulate matter and sampling methods for gaseous pollutants in exhaust from fixed sources of pollution"

      GB 18483 "Emission Standards for Cooking Fumes in the Catering Industry"

      HJ 554 "Technical Specifications for Environmental Protection in the Catering Industry"

      HJ/T 62 "Technical Requirements and Testing Technical Specifications for Cooking Fume Purification Equipment in the Catering Industry"

      HJ/T 38 "Determination of Non Methane Total Hydrocarbons in Exhaust from Fixed Pollution Sources"

      HJ/T48-1999 Technical Conditions for Smoke and Dust Samplers

      JJG 680-2007 "Verification Regulations for Smoke and Dust Samplers"

      JJG 518-1998 "Verification Regulations for Pitot Tubes"

    Performance Characteristics

      1. High precision and durable oil fume collection structure, capable of long-term resistance to high temperature and high humidity environments

      Detect parameters such as oil fume concentration, particulate matter, and non methane total hydrocarbons in the oil fume pipeline through a laser electrochemical comprehensive sensor.

      2 molding processes, compact size, low failure rate

      The sampling part is free of cleaning and maintenance for a long time.

      24-hour uninterrupted measurement of oil fume concentration, real-time data

      Equipped with a built-in lithium battery, it can continuously test for 4 hours on a single charge (with each test lasting less than 10 minutes).

      4 Design Philosophy: Putting People First

      Touch screen, fully Chinese interface, illustrated with text, simple and clear.

      5. Testing parameter settings

      You can change the settings of the inspector, inspection number, inspected unit, inspection location, and start time through the touch screen.

      6. User friendly interface

      The instrument displays four function keys for entering detection, query, maintenance, and settings when turned on, with simple operation.

      7. Intuitive Data

      The instrument detection interface directly displays real-time values, average values, values, and standard limits.

      8 User Password Protection

      User password protection: When performing internal parameter calibration, the correct password must be entered to ensure the security of instrument data.

    Technical Specifications

      parameter range

      

      resolution

      

      error

      

      Oil fume concentration

      

      (0~60.0)mg/m3

      

      0.001mg/m3

      

      ±0.2mg/m3

      

      particulate matter

      

      (0~60.0)mg/m3

      

      0.001mg/m3

      

      ±0.2mg/m3

      

      Non-Methane Total Hydrocarbons (NMTHC)

      

      (0~60.0)mg/m3

      

      0.001mg/m3

      

      ±0.2mg/m3

      

      humidity

      

      (0-100)%RH

      

      0.1%RH

      

      Better than ± 3.0%

      

      Smoke temperature

      

      (0-120)℃

      

      ±0.1℃

      

      Better than ± 3.0 ℃

      

      Smoke humidity

      

      (0-99)%

      

      0.1%

      

      Better than ± 3.5%

      

      dynamic pressure

      

      (0~2500)Pa

      

      0.1Pa

      

      Better than ± 2.0%

      

      static pressure

      

      (-35.00~35.00)kPa

      

      0.001kPa

      

      Better than ± 2.0%

      

      Overall dimensions

      

      Length x Width x Height (114 * 110 * 245)

      

      Total weight

      

      About 2.5kg

      

      working power supply

      

      220V±10%,50Hz

      

    AfterSalesService :

    Key words: