Low background alpha beta measuring instrument for health and epidemic prevention
Low background alpha beta measuring instrument for health and epidemic prevention

Low background alpha beta measuring instrument for health and epidemic prevention

Category:

Instrumentation/Environmental testing instruments/Other environmental testing instruments

Model:

PAB-6000

Brand:

Qingdao Lubo Jianye Environmental Protection Techn

model:

PAB-6000

measurement object:

Used for environmental protection, detecting radioactivity in water, air, soil, and buildings

measurement range:

α≤0.002/cm2·min-1

measurement accuracy:

α=5×10-4Bq;β=1×10-3Bq

Processing & Customization:

yes

Overall dimensions:

See details

weight:

250 Kg

Place of Origin:

Qingdao

manufacturer:

Qingdao Road Expo

Retail Price

123,000.00USD


重量

kg

  • Product Description
  • model

    PAB-6000

    measurement object

    Used for environmental protection, detecting radioactivity in water, air, soil, and buildings

    measurement range

    α≤0.002/cm2·min-1

    measurement accuracy

    α=5×10-4Bq;β=1×10-3Bq

    Processing & Customization

    yes

    Overall dimensions

    See details

    weight

    250 Kg

    Place of Origin

    Qingdao

    manufacturer

    Qingdao Road Expo

    Description :

    Qingdao Road Expo Manufacturer

    PAB-6000 low background alpha beta measuring instrument (four channels)

    Product Introduction

      The PAB-6000 series multi-channel low background alpha/beta measuring instrument is mainly used for measuring the low-level total alpha and total beta radioactivity of various substances. Used for environmental protection, detecting radioactivity in water, air, soil, and buildings; Used for hygiene and epidemic prevention, detecting radioactivity in drinking water, food, vegetables, dairy products, and dairy products; Used for building material inspection, including radioactive testing of granite, marble, sandstone, coal slag bricks, slag bricks, etc; Used for monitoring the emissions, atmosphere, and environment of nuclear power and other nuclear facilities; Other applications include radiation protection, health physics, biomedical research, agriculture, archaeology, geology, etc.

    execution standard

      GB/T11682-2008 "Low background alpha and/or beta measuring instruments"

      JJG853-1993 "National Metrological Verification Regulations for Low Background Alpha and β Measuring Instruments"

      GB5749-2006 "Standard for Drinking Water"

      GB/T 5750.13-2006 "Standard Test Methods for Drinking Water - Radioactive Index"

      GB 8573-2008 "Drinking Natural Mineral Water"

      GB19298-2003 "Hygienic Standards for Bottled (Barreled) Drinking Water"

      HJ/T Technical Specification for Radiation Environment Monitoring

      GB20426-2006 "Emission Standards for Pollutants from Coal Industry"

    Performance Characteristics

      Simultaneously measure 4 samples, each channel is independent, with independent sample delivery, independent measurement, independent data and report output;

      Using anti coincidence nuclear electronics system to remove natural radiation background interference; The sensor uses triphenylene and zinc sulfide (silver) as luminescent materials;

      Using extremely low static current high-voltage DC linear regulator technology to achieve multi-channel adjustable output of a single high-voltage generator;

      Using CPLD (Programmable Logic Device) to achieve high-speed, reliable, and low-energy detection;

      The controller adopts a 2.4-inch TFT true color LCD interactive mode;

      Standard WINDOWS multi document program mode design, universal USB 2.0 standard driver free connection;

      The measurement time, alpha threshold (α), beta low threshold (β L), beta high threshold (β H), and anti coincidence threshold of each detector can be adjusted by computer according to requirements.

      High performance anti coincidence electronics, microcomputer control, setting working points, checking background counting, calibration efficiency (combined with standard sources); Automatically provide table format results, automatically deduct background, and directly obtain the specific activity of the sample (Bg/L, Bg/Kg, Bg/m3)

      Multi channel independent operation, independent timing measurement, can send samples at any time, greatly improving the efficiency of equipment use

      It can measure both alpha and beta simultaneously, or measure alpha or beta separately

      Measurable: water sample, soil sample, oil sample, contaminated wipe (peel off) sample, aerosol sample and other samples

      The fully lead structured lead chamber adopts multi-layer composite shielding, with low background and high sensitivity to detect extremely low levels of radioactivity.

      The instrument can be upgraded to eight channels according to customer needs

    Technical Specifications

      Average background count rate per unit area

      

      α≤0.002/cm2·min-1, β≤0.1/cm2·min-1

      

      Efficiency ratio

      

      α≥85%,β≥58%

      

      Efficiency stability

      

      α<3%,β<5%

      

      Instrument sensitivity

      

      α=5×10-4Bq;β=1×10-3Bq

      

      Crossroad ratio

      

      Alpha rays on beta channels ≤ 2.5%, beta rays on alpha channels ≤ 0.3%

      

      Measurement and control system software

      

      A multi document application that allows for simultaneous measurement, analysis, printing, and other functions

      

      sensor

      

      Plastic Double Flash Sensor Component

      

      Main detector

      

      Using a surface washable scintillator

      

      Number of main detectors

      

      four

      

      Anti coincidence detector

      

      Using plastic scintillators; Coupling of 1 PMT with a 200 * 50 scintillator

      

      Communication link

      

      Driver free USB interface

      

      Use temperature and humidity

      

      5-40℃ ; Relative humidity<90%

      

      power supply

      

      AC 220V ± 10%, 50HZ

      

      Lead chamber weight

      

      250 Kg

      

      Cabinet, controller

      

      Standard 19 inch network cabinet; Standard 19 inch 2U chassis

      

    Qingdao Lubo Environmental Protection provides after-sales and technical support for products!

    AfterSalesService :

    Key words:
    • Low background alpha beta measuring instrument