1000 ton column sensor standard force gauge 10000kN 0.3 level CNAS metrological standard force gauge
Category:
Instrumentation/Mechanical quantity instrument/Force measuring instrument
Model:
1000 ton column sensor standard force gauge 10000kN 0.3 level CNAS metrological standard force gauge
Brand:
Youzhongli
Retail Price
180.00USD
重量
kg
- Product Description
-
Description :
1000 ton column sensor standard force measuring instrument 10000kN 0.3 level CNAS metrological standard force measuring instrument detailed instructions: JJF1469-2014 (Calibration Specification for Strain Gauge Sensor Measuring Instruments), JJG144-2007 (Verification Regulations for Standard Force Measuring Instruments),
JJG557-2011 (Standard Torque Meter Verification Regulations), JJG391-2009 (Load Sensor Verification Regulations),
OIML-R60 (GUO International Legal Metrology Organization Technical Standard for Weighing Sensors)
The NIM-ZY-LS-CL-035 standard load measuring instrument testing/calibration rules, registered with the China Institute of Metrology, are the preliminary technical standards based on which the current dynamometer indicator instrument testing/calibration is carried out. They have been replaced by the JJF1469-2014 standard.





1. The core technology of AC excitation for high-precision force measurement provides extremely stable measurement capability,
2. The ratio voltage provides a measurement capability of 2 million display divisions, with the smallest resolution of 0.001 μ V/V,
3. With a real-time peak measurement capability of up to 10000 times per second, it is suitable for peak detection in dynamic and impact applications,
4. Bidirectional calibration, bidirectional measurement, bidirectional 6-segment linear correction, optional 6/24/40 channels,
5. Peak measurement and holding function, which allows for simultaneous zeroing during peak clearing,
6. Both measurement data and calibration data can be printed out,
7. Data communication (RS232), three communication output formats,
8. One click conversion of units, with load units of N (kN), kg (t), and lb (Klb),
9. Two types of calibration methods: loading calibration and sensitivity data mV/V input calibration,
This section provides a brief introduction to the structural styles and characteristics of commonly used force sensors. For more detailed performance and external dimensions, please consult our company. Sensors are described using the accuracy of full-scale error, while standard force gauges are described using the accuracy of equivalent error. Please note the difference between the two. For more detailed information, please refer to JJG391-2009 (Load Sensor Calibration Regulations), JJG144-2007 (Standard Force Gauge Calibration Regulations), and ISO376-2011 (Testing Machine Force Gauge Calibration Specifications);
S-type sensor: It is a commonly used structural form for measuring small and medium force values, and can be used for tension or pressure measurement with corresponding accessories. It has good metrological performance and moderate price. The range of measurement is 100N~200kN, and the optimal measurement range is 200N~50kN.
Single column sensor: It is a commonly used structure for measuring large and medium force values, with good measurement performance and small weight, and is easy to carry for compression applications. The range of measurement is 30kN~5MN, and the optimal range selection is 100kN~5MN.
JJF1469-2014 (Calibration Specification for Strain Gauge Sensor Measuring Instruments), JJG144-2007 (Verification Regulations for Standard Force Measuring Instruments),
JJG557-2011 (Standard Torque Meter Verification Regulations), JJG391-2009 (Load Sensor Verification Regulations),
OIML-R60 (GUO International Legal Metrology Organization Technical Standard for Weighing Sensors)
The NIM-ZY-LS-CL-035 standard load measuring instrument testing/calibration rules, registered with the China Institute of Metrology, are the preliminary technical standards based on which the current dynamometer indicator instrument testing/calibration is carried out. They have been replaced by the JJF1469-2014 standard.
AfterSalesService :
Key words:- 1000 ton column sensor