Used for smart home, urban community LX33-31 travel switch JOSEF
Category:
Electrical Engineering/switch/Limit switch
Model:
LX33-31
Brand:
Shanghai Joseph
model:
LX33-31
Startup method:
push-button switch
electrical life:
1 million times
Processing & Customization:
yes
Protection level:
IP44
temperature range:
-5-+40
Retail Price
350.00RMB
重量
kg
- Product Description
-
model LX33-31
Startup method push-button switch
electrical life 1 million times
Processing & Customization yes
Protection level IP44
temperature range -5-+40
Description :
model
LX33-12
LX33-32 with heavy hammer and steel wire rope
LX33-22
LX33-12 AC500V 20A
LX33-32 AC500V 20A
LX33-31
LX33-11
LX33-31 with heavy hammer
LX33-42
LX33-32
LX33-4
Product Parameters
The LX33 series travel switch is suitable for AC 50-60Hz; AC380V; DC220V; In a control circuit with a current of 20A, it is used to limit the travel of cranes and various equipment.
Product advantages
This product complies with the GB14048.5-2001 standard.
Scope of Application
LX33 travel switch is suitable for AC 50-60HZ; AC380V; DC220V; In the control circuit with a current of 10A, it serves as a travel limit and terminal protection for the crane's translation mechanism. Normal operation at ambient temperatures ranging from -5 ℃ to+40 ℃; Environmental temperature 90%; Mechanical lifespan of 1 million cycles, protection level IP44; Compliant with IEC337-1 GB14048.5-2001 standard.
Model and meaning


The contact element closing table of the travel switch can be adjusted according to different needs. The contact element closing table of the rod type, fork type, and heavy hammer type travel switch that can be adjusted is shown in Figure 3. The angle at which the contact opening and closing actions are completed is 30 degrees.
working conditions
1. Surrounding air temperature: The surrounding air temperature should not exceed+40 ℃ and should not be lower than -5 ℃ And the average value over 24 hours shall not exceed+35 ℃.
2. Altitude: The altitude of the installation site shall not exceed 2000m.
3 Atmospheric conditions: When the temperature is+40 ℃, the relative humidity of the air does not exceed 50%. At lower temperatures, there can be higher relative humidity, such as up to 90% at 20 ℃. Due to occasional temperature changes
Special measures should be taken for the condensation of raw materials.
4 places with no significant shaking or impact vibration.
In a medium without explosive hazards, and without gases and dust (including conductive dust) that can corrode metals and damage insulation.



Key words:- limit switch