UEG/A-4DPDT/250VDC single position intermediate relay JOSEF for water conservancy and hydropower plants

UEG/A-4DPDT/250VDC single position intermediate relay JOSEF for water conservancy and hydropower plants

Category:

electron/electrical/Liquid level controller

Model:

UEG/A-4DPDT/250VDC

Brand:

Shanghai Joseph

model:

UEG/A-4DPDT/250VDC

rated voltage:

two hundred and twenty

Place of Origin:

Shanghai

Retail Price

200.00RMB


重量

kg

  • Product Description
  • model

    UEG/A-4DPDT/250VDC

    rated voltage

    two hundred and twenty

    Place of Origin

    Shanghai

    Description :

      Application scenarios and characteristics:

      During the operation and handling of the power system, unpredictable disturbances can occur, which can interfere with the control circuit through the coupling of inductance and capacitance, leading to control circuit misoperation.

      Anti interference relays utilize starting power technology and voltage gate settings to effectively solve the problem of system interference misoperation.

      According to the power regulations, anti-interference relays (such as three-phase inconsistent outlet relays, transformer gas trip relays, outlet relays) should be used for circuit breakers with straight circuit breakers

      Relay parameters meet technical requirements: starting power of 25W (power corresponding to relay starting voltage);

      Electrical starting voltage range: 55%~70Un

      Relay action time greater than 10ms and less than 35ms

      When a power frequency AC voltage with an effective value of 220 volts is applied to both ends of the relay coil, the relay output contacts reliably do not operate

      The product terminal contacts are made of all copper material

      Modular structure design, using different structures based on the number of connections to save space

      UEG/A-1H/24V single position intermediate relay; UEG/A-1H1D/24VDC single position intermediate relay;

      UEG/A-1H1D/48VDC single position intermediate relay; UEG/A-1H1D/110VDC single position intermediate relay;

      UEG/A-1H1D/110VAC single position intermediate relay; UEG/A-1H1D/220VDC single position intermediate relay;

      UEG/A-1H1D/220VAC single position intermediate relay; UEG/A-1H1D/125VDC single position intermediate relay;

      UEG/A-1H1D/125VAC single position intermediate relay; UEG/A-1H1D/250VDC single position intermediate relay;

      UEG/A-2H/24VDC single position intermediate relay; UEG/A-2H/48VDC single position intermediate relay;

      UEG/A-2H/110VDC single position intermediate relay; UEG/A-2H/110VAC single position intermediate relay;

      UEG/A-2H/220VDC single position intermediate relay; UEG/A-2H/220VAC single position intermediate relay;

      UEG/A-2H/125VDC single position intermediate relay; UEG/A-2H/125VAC single position intermediate relay;

      UEG/A-2H/250VDC single position intermediate relay; UEG/A-2DPDT/24VDC single position intermediate relay;

      UEG/A-2DPDT/48VDC single position intermediate relay; UEG/A-2DPDT/110VDC single position intermediate relay;

      UEG/A-2DPDT/110VAC single position intermediate relay; UEG/A-2DPDT/220VDC single position intermediate relay;

      UEG/A-2DPDT/220VAC single position intermediate relay; UEG/A-2DPDT/125VDC single position intermediate relay;

      UEG/A-2DPDT/125VAC single position intermediate relay; UEG/A-2DPDT/250VDC single position intermediate relay;

      UEG/A-1H3D/24VDC single position intermediate relay; UEG/A-1H3D/48VDC single position intermediate relay;

      UEG/A-1H3D/110VDC single position intermediate relay; UEG/A-1H3D/110VAC single position intermediate relay;

      UEG/A-1H3D/220VDC single position intermediate relay; UEG/A-1H3D/220VAC single position intermediate relay;

      UEG/A-1H3D/125VDC single position intermediate relay; UEG/A-1H3D/125VAC single position intermediate relay;

      UEG/A-1H3D/250VDC single position intermediate relay; UEG/A-2H2D/24VDC single position intermediate relay;

      UEG/A-2H2D/48VDC single position intermediate relay; UEG/A-2H2D/110VDC single position intermediate relay;

      UEG/A-2H2D/110VAC single position intermediate relay; UEG/A-2H2D/220VDC single position intermediate relay;

      UEG/A-2H2D/220VAC single position intermediate relay; UEG/A-2H2D/125VDC single position intermediate relay;

      UEG/A-2H2D/125VAC single position intermediate relay; UEG/A-2H2D/250VDC single position intermediate relay;

      UEG/A-4DPDT/24VDC single position intermediate relay; UEG/A-4DPDT/48VDC single position intermediate relay;

      UEG/A-4DPDT/110VDC single position intermediate relay; UEG/A-4DPDT/110VAC single position intermediate relay;

      UEG/A-4DPDT/220VDC single position intermediate relay; UEG/A-4DPDT/220VAC single position intermediate relay;

      UEG/A-4DPDT/125VDC single position intermediate relay; UEG/A-4DPDT/125VAC single position intermediate relay;

      UEG/A-4DPDT/250VDC single position intermediate relay; UEG/A-4H/24VDC single position intermediate relay;

      UEG/A-4H/48VDC single position intermediate relay; UEG/A-4H/110VDC single position intermediate relay;

      UEG/A-4H/110VAC single position intermediate relay; UEG/A-4H/220VDC single position intermediate relay;

      UEG/A-4H/220VAC single position intermediate relay; UEG/A-4H/125VDC single position intermediate relay;

      UEG/A-4H/125VAC single position intermediate relay; UEG/A-4H/250VDC single position intermediate relay;

      UEG/A-6H/24VDC single position intermediate relay; UEG/A-46H/48VDC single position intermediate relay;

      UEG/A-6H/110VDC single position intermediate relay; UEG/A-6H/110VAC single position intermediate relay;

      UEG/A-6H/220V DC single position intermediate relay; UEG/A-6H/220V AC single position intermediate relay;

      UEG/A-6H/125VDC single position intermediate relay; UEG/A-6H/125VAC single position intermediate relay;

      UEG/A-6H/250VDC single position intermediate relay; UEG/A-6DPDT/24VDC single position intermediate relay;

      UEG/A-6DPDT/48VDC single position intermediate relay; UEG/A-6DPDT/110VDC single position intermediate relay;

      UEG/A-6DPDT/110VAC single position intermediate relay; UEG/A-6DPDT/220VDC single position intermediate relay;

      UEG/A-6DPDT/220VAC single position intermediate relay; UEG/A-6DPDT/125VDC single position intermediate relay;

      UEG/A-6DPDT/125VAC single position intermediate relay; UEG/A-6DPDT/250VDC single position intermediate relay;

      UEG/A-8H/24VDC single position intermediate relay; UEG/A-8H/48VDC single position intermediate relay;

      UEG/A-8H/110VDC single position intermediate relay; UEG/A-8H/110VAC single position intermediate relay;

      UEG/A-8H/220V DC single position intermediate relay; UEG/A-8H/220V AC single position intermediate relay;

      UEG/A-8H/125VDC single position intermediate relay; UEG/A-8H/125VAC single position intermediate relay;

      UFG/A-8H/250VDC single position intermediate relay; UEG/A-8DPDT/24VDC single position intermediate relay;

      UEG/A-8DPDT/48VDC single position intermediate relay; UEG/A-8DPDT/110VDC single position intermediate relay;

      UEG/A-8DPDT/110VAC single position intermediate relay; UEG/A-8DPDT/220VDC single position intermediate relay;

      UEG/A-8DPDT/220VAC single position intermediate relay; UEG/A-8DPDT/125VDC single position intermediate relay;

      UEG/A-8DPDT/125VAC single position intermediate relay; UEG/A-8DPDT/250VDC single position intermediate relay;

      Application field images:

    Key words:
    • intermediate relay