JOSEF timed current relay JL-8D/2X112A5G AC220V 0.1-9.9S 0.1-9.9A
Category:
electron/electrical/Liquid level controller
Model:
JL-8D/2X112A5G
Brand:
Shanghai Joseph
model:
JL-8D/2X112A5G
Processing & Customization:
yes
rated voltage:
two hundred and twenty
Place of Origin:
Shanghai
manufacturer:
Shanghai Joseph
Retail Price
120.00RMB
重量
kg
- Product Description
-
model JL-8D/2X112A5G
Processing & Customization yes
rated voltage two hundred and twenty
Place of Origin Shanghai
manufacturer Shanghai Joseph
Description :
Current Relay JL-8GB/11 Power Supply: 220AC/DC Set Current: 0.03-9.99AAC
Current relay JL-8GA/21
Overcurrent relay JL-8GB/1 AC220V 0.1-9.9A
Current relay JL-8B/521DK (XJL-52/DK) 0.5-3A
Current relay JL-8B/222DK
Front wiring of current relay JL-8B/1121 board
Current relay JL-8B/12 DC220V 0.1-99.9AAC
Current Relay JL-8B/3211 0.03~9.99A Auxiliary Power Supply: 110~220V AC/DC Universal Rail Installation
Current relay JL-8B/E2 110VDC board rear wiring
Current relay JL-8B/E3 DC110V 30A
Overcurrent relay JL-8B/1211 0.03-0.999A, AC220V in front of the guide rail plate
Current relay JL-8B/1331G rail mounted installation
Current relay JL-8B/322DK setting range: 1-6A XJL-32/DK board front wiring
Current relay JL-8B/2211 with base
Current relay JL-8B/1111 0.03~0.999A
Current relay JL-8B/1221 0.03~9.99A
Current relay JL-8B/512DK rail type board front wiring 1-6A
Current relay JL-8GA/21
Non auxiliary current relay JL-8A/11DK 0.1~9.9A
Overcurrent relay JL-8C/32-3
Zero sequence current relay JL-8C/11-31 DC220V
Zero sequence current relay JL-8C-12-2-2 (SX) 85-260VAC/DC
Front wiring of current relay JL-8D/2X board
Fixed time overcurrent relay JL-8D/2X122A4 100~300VDC 0~9.9A board front wiring
Fixed time current relay JL-8D/2X112A5G AC220V 0.1~9.9S 0.1~9.9A
Current relay JL-8D/2X112A5 DC220V rail mounted installation
Fixed time overcurrent relay JL-8D/2X122A4DG 220V
Time limited current relay is a relay protection device used in power systems, mainly used to detect overcurrent conditions in circuits and trigger corresponding actions based on a set time delay. Its main function is to cut off the circuit after a predetermined time delay in the event of an overcurrent fault, in order to protect the circuit and equipment from damage.
The working principle of a timed current relay is based on the relationship between current and time. When the current in the circuit exceeds the set value, the relay starts timing. After reaching the preset delay time, if the overcurrent state still exists, the relay will trigger action, usually by opening the contacts to cut off the circuit. This delay characteristic enables the relay to avoid misoperation in brief overcurrent situations, and to promptly cut off the circuit in the event of sustained overcurrent faults.
Time limited current relays have multiple advantages. Firstly, it can flexibly set the delay time according to actual needs to meet the protection requirements of different circuits and devices. Secondly, it has high sensitivity and reliability, which can accurately detect overcurrent faults and quickly cut off circuits, preventing equipment damage and dangerous situations such as fires from occurring. In addition, timed current relays also have good anti-interference ability and can operate stably in complex electromagnetic environments.
In practical applications, timed current relays are widely used in power system equipment such as generators, transformers, and transmission lines. It can be used in conjunction with other protective devices to build a comprehensive protection system, ensuring the safe and stable operation of the power system. Meanwhile, with the continuous development of technology, timed current relays are also constantly being improved and innovated to meet the increasingly complex protection requirements of power systems.


Key words:- Current relay