JOSEF timed overcurrent relay JL-8D/2X122A4 100-300VDC 0-9.9A board front wiring
Category:
electron/electrical/Liquid level controller
Model:
JL-8D/2X122A4
Brand:
Shanghai Joseph
model:
JL-8D/2X122A4
Processing & Customization:
yes
rated voltage:
two hundred and twenty
Place of Origin:
Shanghai
Retail Price
115.00RMB
重量
kg
- Product Description
-
model JL-8D/2X122A4
Processing & Customization yes
rated voltage two hundred and twenty
Place of Origin Shanghai
Description :
purpose
Terminal block integrated circuit current relay (hereinafter referred to as current relay) is mainly used as a relay protection component in the transmission and transformation lines of generators and transformers. It serves as a starting element for AC circuit overload or short circuit in power systems, providing alarm signals or cutting off faults.
Technical data
Setting range: 0.03A~9.99A, with a step difference of 0.01A; 0.3A~99.9A, with a step difference of 0.1A
Action time: 1.2 times the set current, action time not exceeding 25ms;
Twice the set current, with an action time not exceeding 20ms
Return coefficient: overcurrent relay: 0.9~0.97; Undercurrent relay: 1.05~1.15.
Insulation resistance: The live terminals of the relay are connected together, and the insulation resistance between the exposed non live terminals or the outer shell is measured with a megohmmeter with an open circuit voltage of 500V and not less than 300MQ.
Dielectric strength: The live terminals of the relay are connected together, and the non live terminals exposed to the outside or between the casings can withstand an effective value of 2000V, 50H AC power, which is small and lasts for 1 minute without breakdown or flashover.






Current Relay JL-8GB/11 Power Supply: 220AC/DC Set Current: 0.03-9.99AAC Current relay JL-8GA/21
Overcurrent relay JL-8GB/1 AC220V 0.1-9.9A
Current relay JL-8B/521DK (XJL-52/DK) 0.5-3A
Current relay JL-8B/222DK
Front wiring of current relay JL-8B/1121 board
Current relay JL-8B/12 DC220V 0.1-99.9AAC
Current Relay JL-8B/3211 0.03~9.99A Auxiliary Power Supply: 110~220V AC/DC Universal Rail Installation
Current relay JL-8B/E2 110VDC board rear wiring
Current relay JL-8B/E3 DC110V 30A
Overcurrent relay JL-8B/1211 0.03-0.999A, AC220V in front of the guide rail plate
Current relay JL-8B/1331G rail mounted installation
Current relay JL-8B/322DK setting range: 1-6A XJL-32/DK board front wiring
Current relay JL-8B/2211 with base
Current relay JL-8B/1111 0.03~0.999A
Current relay JL-8B/1221 0.03~9.99A
Current relay JL-8B/512DK rail type board front wiring 1-6A
Current relay JL-8GA/21
Non auxiliary current relay JL-8A/11DK 0.1~9.9A
Overcurrent relay JL-8C/32-3
Zero sequence current relay JL-8C/11-31 DC220V
Zero sequence current relay JL-8C-12-2-2 (SX) 85-260VAC/DC
Front wiring of current relay JL-8D/2X board
Fixed time overcurrent relay JL-8D/2X122A4 100~300VDC 0~9.9A board front wiring
Fixed time current relay JL-8D/2X112A5G AC220V 0.1~9.9S 0.1~9.9A
Current relay JL-8D/2X112A5 DC220V rail mounted installation
Fixed time overcurrent relay JL-8D/2X122A4DG 220V
Key words:- Timed limit