JOSEF timed overcurrent relay JL-8D/2X122A4 100-300VDC 0-9.9A board front wiring

JOSEF timed overcurrent relay JL-8D/2X122A4 100-300VDC 0-9.9A board front wiring

Category:

electron/electrical/Liquid level controller

Model:

JL-8D/2X122A4

Brand:

Shanghai Joseph

model:

JL-8D/2X122A4

Processing & Customization:

yes

rated voltage:

two hundred and twenty

Place of Origin:

Shanghai

Retail Price

115.00RMB


重量

kg

  • Product Description
  • model

    JL-8D/2X122A4

    Processing & Customization

    yes

    rated voltage

    two hundred and twenty

    Place of Origin

    Shanghai

    Description :

      purpose

      Terminal block integrated circuit current relay (hereinafter referred to as current relay) is mainly used as a relay protection component in the transmission and transformation lines of generators and transformers. It serves as a starting element for AC circuit overload or short circuit in power systems, providing alarm signals or cutting off faults.

      Technical data

      Setting range: 0.03A~9.99A, with a step difference of 0.01A; 0.3A~99.9A, with a step difference of 0.1A

      Action time: 1.2 times the set current, action time not exceeding 25ms;

      Twice the set current, with an action time not exceeding 20ms

      Return coefficient: overcurrent relay: 0.9~0.97; Undercurrent relay: 1.05~1.15.

      Insulation resistance: The live terminals of the relay are connected together, and the insulation resistance between the exposed non live terminals or the outer shell is measured with a megohmmeter with an open circuit voltage of 500V and not less than 300MQ.

      Dielectric strength: The live terminals of the relay are connected together, and the non live terminals exposed to the outside or between the casings can withstand an effective value of 2000V, 50H AC power, which is small and lasts for 1 minute without breakdown or flashover.

      

    Current Relay JL-8GB/11 Power Supply: 220AC/DC Set Current: 0.03-9.99AAC

      Current relay JL-8GA/21

      Overcurrent relay JL-8GB/1 AC220V 0.1-9.9A

      Current relay JL-8B/521DK (XJL-52/DK) 0.5-3A

      Current relay JL-8B/222DK

      Front wiring of current relay JL-8B/1121 board

      Current relay JL-8B/12 DC220V 0.1-99.9AAC

      Current Relay JL-8B/3211 0.03~9.99A Auxiliary Power Supply: 110~220V AC/DC Universal Rail Installation

      Current relay JL-8B/E2 110VDC board rear wiring

      Current relay JL-8B/E3 DC110V 30A

      Overcurrent relay JL-8B/1211 0.03-0.999A, AC220V in front of the guide rail plate

      Current relay JL-8B/1331G rail mounted installation

      Current relay JL-8B/322DK setting range: 1-6A XJL-32/DK board front wiring

      Current relay JL-8B/2211 with base

      Current relay JL-8B/1111 0.03~0.999A

      Current relay JL-8B/1221 0.03~9.99A

      Current relay JL-8B/512DK rail type board front wiring 1-6A

      Current relay JL-8GA/21

      Non auxiliary current relay JL-8A/11DK 0.1~9.9A

      Overcurrent relay JL-8C/32-3

      Zero sequence current relay JL-8C/11-31 DC220V

      Zero sequence current relay JL-8C-12-2-2 (SX) 85-260VAC/DC

      Front wiring of current relay JL-8D/2X board

      Fixed time overcurrent relay JL-8D/2X122A4 100~300VDC 0~9.9A board front wiring

      Fixed time current relay JL-8D/2X112A5G AC220V 0.1~9.9S 0.1~9.9A

      Current relay JL-8D/2X112A5 DC220V rail mounted installation

      Fixed time overcurrent relay JL-8D/2X122A4DG 220V

    Key words:
    • Timed limit