JOSEF zero sequence current relay JL-8C/11-31 DC220V has good stability
Category:
electron/electrical/Liquid level controller
Model:
JL-8C/11-31
Brand:
Shanghai Joseph
model:
JL-8C/11-31
Processing & Customization:
yes
rated voltage:
two hundred and twenty
Place of Origin:
Shanghai
manufacturer:
Shanghai Joseph
Retail Price
125.00RMB
重量
kg
- Product Description
-
model JL-8C/11-31
Processing & Customization yes
rated voltage two hundred and twenty
Place of Origin Shanghai
manufacturer Shanghai Joseph
Description :
Current Relay JL-8GB/11 Power Supply: 220AC/DC Set Current: 0.03-9.99AAC
Current relay JL-8GA/21
Overcurrent relay JL-8GB/1 AC220V 0.1-9.9A
Current relay JL-8B/521DK (XJL-52/DK) 0.5-3A
Current relay JL-8B/222DK
Current relay JL-8B/1331G rail mounted installation
Current relay JL-8B/322DK setting range: 1-6A XJL-32/DK board front wiring
Current relay JL-8B/2211 with base
Current relay JL-8B/1111 0.03~0.999A
Current relay JL-8B/1221 0.03~9.99A
Current relay JL-8B/512DK rail type board front wiring 1-6A
Current relay JL-8GA/21
Non auxiliary current relay JL-8A/11DK 0.1~9.9A
Overcurrent relay JL-8C/32-3
Zero sequence current relay JL-8C/11-31 DC220V
Zero sequence current relay JL-8C-12-2-2 (SX) 85-260VAC/DC
Front wiring of current relay JL-8D/2X board
Fixed time overcurrent relay JL-8D/2X122A4 100~300VDC 0~9.9A board front wiring
Fixed time current relay JL-8D/2X112A5G AC220V 0.1~9.9S 0.1~9.9A
Current relay JL-8D/2X112A5 DC220V rail mounted installation
Fixed time overcurrent relay JL-8D/2X122A4DG 220V
Technical data
Setting range: 0.03A~9.99A, with a step difference of 0.01A; 0.3A~99.9A, with a step difference of 0.1A
Action time: 1.2 times the set current, action time not exceeding 25ms;
Twice the set current, with an action time not exceeding 20ms
Return coefficient: overcurrent relay: 0.9~0.97; Undercurrent relay: 1.05~1.15.
Setting error: less than 2%
Power consumption: When the relay does not operate, the power consumption is less than 4W. When the relay operates, the power consumption is less than 5W;
Contact capacity: When the voltage is not greater than 250V, the continuous current of the contact is 5A; when the medium voltage is not greater than 250V, a DC circuit breaker with a time constant L/R of 5ms can disconnect 30W. In an AC circuit with a power factor COS of 04 when the voltage is not greater than 250V, it can disconnect 200VA.
Contact life: electrical life: 105 times, mechanical life: 106 times.
Insulation resistance: The live terminals of the relay are connected together, and the insulation resistance between the exposed non live terminals or the outer shell is measured with a megohmmeter with an open circuit voltage of 500V and not less than 300MQ.
Dielectric strength: The live terminals of the relay are connected together, and the non live terminals exposed to the outside or between the casings can withstand an effective value of 2000V, 50H AC power, which is small and lasts for 1 minute without breakdown or flashover.





Key words:- Current relay