JOSEF voltage relay DY-31/200 board front wiring has low power consumption and high precision
Category:
electron/electrical/Liquid level controller
Model:
DY-31/200
Brand:
Shanghai Joseph
model:
DY-31/200
Processing & Customization:
yes
rated voltage:
two hundred and twenty
Place of Origin:
Shanghai
manufacturer:
Shanghai Joseph
Retail Price
155.00RMB
重量
kg
- Product Description
-
model DY-31/200
Processing & Customization yes
rated voltage two hundred and twenty
Place of Origin Shanghai
manufacturer Shanghai Joseph
Description :
One purpose
DY series voltage relays are used in relay protection circuits as action components for overvoltage protection or low-voltage lockout.
working principle
The relay is electromagnetic and operates instantaneously. The magnetic system has two coils, with the coil heads connected to the base terminals. Users can connect the coils in series or parallel as needed, thus doubling the setting range of the relay.
The scale value and rated value of the relay are sufficient when the coils are connected in parallel (in V units). Rotate the pointer on the dial to change the reaction torque of the balance spring, thereby changing the action value of the relay.
Relay action: For overvoltage relays, when the voltage rises to or exceeds the set value, the relay will act, closing the dynamic contact and disconnecting the dynamic contact. When the voltage drops to 0.8 times the set value, the relay returns, the dynamic contact opens, and the dynamic contact closes. For low-voltage relays, when the voltage drops to the set voltage, the relay acts, the dynamic contact opens, and the dynamic contact closes
II Technical Specifications
DY-32/60C and DY-34/60C specifications are long-term thermal stable (with built-in series capacitors) voltage relays.
● Relay scale limit error: not greater than 6%.
● Variation of action value: not greater than 6%.
The return coefficient of voltage relays DY-31, 32, 33, and 34 shall not be less than 0.8; DY-35、 The return coefficient of low voltage relays 36, 37, and 38 shall not exceed 1.25.
Action Time
For overvoltage relays
At 1.1 times the action value, the action time should not exceed 0.12s; at 2 times the action value, the action time should not exceed 0.04s.
For low-voltage relays
When the working voltage of the relay is 0.5 times the set voltage, the action time shall not exceed 0.15 seconds.
When the relative humidity of the surrounding air is not greater than 85%, the insulation resistance of the relay circuit to the shell (non-conductive metal part on the shell) should not be less than 300M Ω when measured with a 500V megohmmeter.
The insulation of the conductive part of the relay to the shell (non-conductive metal part on the shell) can withstand a test of 50Hz AC voltage 2kV for 1 minute.
● Contact breaking capacity: When the voltage is not greater than 250V and the current is not greater than 2A, the breaking power of the contact is 50W in a DC circuit with inductive load (time constant not greater than 5 × 10-3s) and 250VA in an AC circuit.
Power consumption: At the minimum setting value, the power consumed by the coil of the relay does not exceed 20VA.
When the temperature of the surrounding medium is+40 ℃, the relay can operate for a long time under the long-term allowable current and voltage shown in Table 2 and Table 3 without damage to insulation and other electrical components, and the temperature rise of the coil is not greater than 65 ℃.
● Lifespan: The relay has an electrical lifespan of 500 times and a mechanical lifespan of 5000 times.
Usage and maintenance
Before using the relay, the housing needs to be removed, the machine needs to be pulled out, and there should be no damage caused during transportation: such as the moving plate touching the magnetic plate, the balance spring coils touching each other, friction on the moving plate shaft, etc. Therefore, set the pointer of the relay to the * setting point, manually rotate the movable system towards the magnetic plate direction, and then release it. The movable system should return to its original equilibrium position until the stop, and then make necessary adjustments and settings.
When readjusting the relay, it must be ensured.
The axial movement of the movable system is between 0.15 and 0.3mm.
The air gap between the rotor and the magnetic pole should ensure that the rotor and the magnetic plate do not collide under any specified working conditions of the relay.
Relays with dynamic contact points and dynamic contact points must not have bridge shaped contacts simultaneously make contact with dynamic contact points and dynamic contact points during operation.
When the pointer rotates from the * scale value to the * final scale value, the coils of the balance spring must not touch each other.
When the relay is activated, the bridge shaped contact should slide on the centerline of the static contact (tolerance ± 1mm), and the total air gap between the dynamic and static contacts should not be less than 2mm.
Rear wiring of voltage relay DY-32/60C board
Voltage relay DY-36/160V board front with seat
Voltage relay DY-23C/60C with board front base
Voltage relay DY-29C setting value: 40-160V. Wiring in front of the fixed installation board inside the cabinet
Fixed installation of voltage relay DY-36 220VDC cabinet bottom plate
Fixed bottom plate of voltage relay DY-36/60C 220VDC cabinet
Voltage relay DY-29C/160 40~160V board front wiring
Voltage relay DY-48 set voltage AC160V, protruding board front wiring, 2 closed points and 1 open point
Front wiring socket of voltage relay DY-34/60C board
Voltage relay DY-38 setting voltage range: 12~48V Contact form: one normally open and two normally closed
Low voltage relay DY-28C/160
Voltage relay DY-34 100VAC 15~30V board rear wiring
Installation of voltage relay DY-54G 33~132V rail
Voltage relay DY-24C/60C
Voltage relay DY-36 80~320V with base
Voltage relay DY-23C, D type, rated voltage 200V, 50~200V
Voltage relay DY-35, rated voltage 48V, 12-48V, including base
Voltage relay DY-32/200 50~200V board front with seat
Front wiring of voltage relay DY-31/200 board
Overvoltage relay DY-21C voltage setting range 50-200V board front with seat
Front wiring of voltage relay DY-34/60C-TH board
Voltage relay DY-24C/200 50-200V board front wiring
Front wiring of voltage relay DY-31 15~60 board








Key words:- voltage relay