Portable rapid oil fume detector - Emission standard for cooking fume in the catering industry - Non methane total hydrocarbon particulate matter - Oil fume concentration
Portable rapid oil fume detector - Emission standard for cooking fume in the catering industry - Non methane total hydrocarbon particulate matter - Oil fume concentration

Portable rapid oil fume detector - Emission standard for cooking fume in the catering industry - Non methane total hydrocarbon particulate matter - Oil fume concentration

Category:

Instrumentation/Environmental testing instruments/Ozone detection instrument

Model:

XY-3100E

Brand:

Qingdao Xinye Environmental Protection

model:

XY-3100E

type:

handheld

measurement object:

Oil fume concentration

measurement range:

(0~50.0)mg/m3

measurement accuracy:

When ≤ 2mg/m3, it is better than ± 0.2mg/m3, and>; Better than ± 5% FS at 2mg/m3

resolution:

0.01mg/m3

power supply:

220V

Processing & Customization:

yes

weight:

three point three

manufacturer:

Qingdao Xinye

Retail Price

16,800.00USD


重量

kg

  • Product Description
  • model

    XY-3100E

    type

    handheld

    measurement object

    Oil fume concentration

    measurement range

    (0~50.0)mg/m3

    measurement accuracy

    When ≤ 2mg/m3, it is better than ± 0.2mg/m3, and>; Better than ± 5% FS at 2mg/m3

    resolution

    0.01mg/m3

    power supply

    220V

    Processing & Customization

    yes

    weight

    three point three

    manufacturer

    Qingdao Xinye

    Description :

    productOverview

      XY-3076 portable oil fume detector (hereinafter referred to as the detector) is a high-precision portable integrated multifunctional oil fume detector. The instrument adopts imported sensors and comes with temperature and pressure compensation correction. It has the advantages of high measurement accuracy, corrosion resistance, and wide temperature range. It is widely used in restaurants, canteens, hotels, environmental monitoring stations, universities, scientific research institutions, urban teams, etc. to detect the concentration of oil fume emissions and working parameters.

    execution standard

      HJ2526-2012 "Technical Standard for Portable Dietary Oil Fume Detector"

      GB "Emission Standards for Cooking Fumes in the Catering Industry"

      DB11/1488 "Emission Standards for Air Pollutants from the Catering Industry in Beijing"

      SZDB/Z 254-2017 "Specification for Oil Fume Emission Control in the Catering Industry"

      GB/T "Determination of particulate matter and sampling methods for gaseous pollutants in exhaust from fixed pollution sources"

    productfeature

      1. The flue gas flow rate is measured using an inlet pressure differential sensor;

      2. Adopting a 4.3-inch high-resolution LCD touch industrial screen, the operation interface is simple and easy to learn, and it is clearly visible under strong light;

      3. Equipped with high-efficiency lithium batteries as standard, it can ensure long-term measurement data;

      4. The whole machine has a compact structure, a reasonable layout, and is convenient for sampling personnel to carry and use;

      5. The whole machine is made of corrosion-resistant 316 stainless steel, suitable for various working conditions, beautiful and corrosion-resistant;

      6. Equipped with a micro Bluetooth printer as standard, making it convenient for customers to print inspection data on site;

      7. Comes with USB export function as standard, making it convenient for customers to view data on their computer.

      8. Standard 232 serial port function, which can achieve one click software upgrade.

      9. The gun body is heated throughout the entire process, and the heating temperature can be set;

      10. It can display the instantaneous value of oil fume in real time and record the mean and peak values;

      11. Automatically calculate parameters such as average gas flow rate, average pressure, and flue gas flow rate.

      12. Adopting an integrated design to reduce external interference and make it easy to use;

    Technical Specifications

    Main parameters

      

    parameter range

      

    resolution

      

    accuracy

      

      atmospheric pressure

      

      (60~120)kPa

      

      0.001kPa

      

      Not exceeding ± 0.5kPa

      

      Smoke dynamic pressure

      

      (0-3500)Pa

      

      1Pa

      

      Better than ± 2.0%

      

      Smoke static pressure

      

      (-35~35) kPa

      

      0.01kPa

      

      Better than ± 4.0%

      

      Smoke velocity

      

      (0~45)m/s

      

      0.1m/s

      

      Better than ± 4.0%

      

      humidity ratio

      

      (0~60)%

      

      0.1%

      

      Better than ± 1.5%

      

      Smoke temperature

      

      <400℃

      

      Particle concentration

      

      0~50mg/m3

      

      0.01mg/m3

      

      <0.1mg/m3:±0.015mg/m3

      &>0.1mg/m3: ± 15% reading

      

      Oil fume concentration

      

      0~30mg/m3

      

      0.01mg/m3

      

      <0.1mg/m3:±0.015mg/m3

      &>0.1mg/m3: ± 15% reading

      

      TVOCs concentration (optional)

      

      1-100ppm

      

      0.1ppm

      

      ±5% F.S

      

      NMHC concentration

      (Optional)

      

      1-130mg/m3

      

      0.1mg/m3

      

      ±5% F.S

      

      Sampling tube length 0.6 meters

      

      0.6 meters (customizable for other lengths)

      

      Total weight

      

      About 10.5KG (including battery)

      

      Total power consumption

      

      ≤130w

      

      charging power supply

      

      24V5A

      

      Overall dimensions

      

      Length x width x height=890 x 155 x 135 mm

      

    AfterSalesService :

    Key words:
    • Quick oil fume detector