Portable BOD Rapid Analyzer Biochemical Oxygen Demand Analyzer 1S Detection Data Direct Reading Suitable for Rapid Detection
Portable BOD Rapid Analyzer Biochemical Oxygen Demand Analyzer 1S Detection Data Direct Reading Suitable for Rapid Detection

Portable BOD Rapid Analyzer Biochemical Oxygen Demand Analyzer 1S Detection Data Direct Reading Suitable for Rapid Detection

Category:

Environmental Protection/Analytical instruments/BOD measuring instrument

Model:

XY-880H

Brand:

Qingdao Xinye Environmental Protection

model:

XY-880H

type:

portable

measurement range:

0-5000mg/L

measurement accuracy:

2%

power supply voltage:

220v

Processing & Customization:

yes

measurement object:

BOD

weight:

209kg

Measuring principle:

Fluorescence spectroscopy

Sample measurement time:

1s

injection method:

automatic

Retail Price

18,600.00USD


重量

kg

  • Product Description
  • model

    XY-880H

    type

    portable

    measurement range

    0-5000mg/L

    measurement accuracy

    2%

    power supply voltage

    220v

    Processing & Customization

    yes

    measurement object

    BOD

    weight

    209kg

    Measuring principle

    Fluorescence spectroscopy

    Sample measurement time

    1s

    injection method

    automatic

    Description :

      1、 Product Usage:

      The BOD rapid analyzer is a standard industrial output type biochemical oxygen demand (BOD) rapid measurement instrument, which has the characteristics of high accuracy, good stability, and simple use. It can be widely used for the detection of various industries (industrial wastewater, urban sewage, domestic sewage, and surface water in rivers and lakes) wastewater.

      This product has greatly improved in terms of stability, accuracy, measurement range, and practicality. Suitable for various needs of different users, it can be applied in the detection of industrial wastewater such as chemical, petroleum, coking, papermaking, metallurgy, brewing, and pharmaceuticals, as well as various domestic wastewater.

      2、 Parameter technical indicators

      Measurement range 0-1000mg/L/0-10000mg/L

      Measurement accuracy 0.5%

      Measurement method: Fluorescence spectroscopy

      Measurement time: less than or equal to 3 seconds

      Resolution 1mg/L

      Response time (T90, seconds) 1 second

      Operating temperature -40 ℃ to+85 ℃

      Working humidity environment 0% -90% RH (relative humidity), non condensing

      Work pressure range: ± 10% of atmospheric pressure

      Probe size φ 32 × 201 (mm)

      Probe cable size 5 meters (default)

      Charger AC 220V 50Hz

    3、 Product features:

      1. The instrument adopts fluorescence spectroscopy, which has the characteristics of small size, portability, and flexibility.

      2. Adopting a dual-purpose AC/DC power supply.

      3. It can be used in the laboratory and meets the requirements for on-site testing in areas without electricity in the field.

      4. BOD on-site detection is a domestic start-up, and this instrument complies with relevant industry standards of the State Environmental Protection Administration. The testing method is included in the "Water and Wastewater Analysis Methods"

    AfterSalesService :

    Key words:
    • Portable BOD rapid analyzer