Handheld fast oil fume detector, oil fume non methane total hydrocarbon particulate matter three in one oil fume analyzer XY-5021
Category:
Instrumentation/Gas analyzer/Smoke and dust detector
Model:
XY-2000E
Brand:
Qingdao Xinye Environmental Protection
model:
XY-2000E
Specifications:
375*260*210mm
type:
Smoke and dust
Processing & Customization:
yes
Product weight:
four point eight
Working environment temperature:
-20-45
noise:
ninety-five
Sampling flow range:
0-110L/min
Sampling flow accuracy:
Better than ± 2.5% FS
manufacturer:
Qingdao Xinye
Retail Price
1,680.00USD
重量
kg
- Product Description
-
model XY-2000E
Specifications 375*260*210mm
type Smoke and dust
Processing & Customization yes
Product weight four point eight
Working environment temperature -20-45
noise ninety-five
Sampling flow range 0-110L/min
Sampling flow accuracy Better than ± 2.5% FS
manufacturer Qingdao Xinye
Description :
XY-5021 Handheld Rapid Oil Fume Detector Oil Fume Non Methane Total Hydrocarbon Particle Three in One Oil Fume Analyzer
XY-5021 Handheld Rapid Oil Fume Detector

Product Overview
The XY-5021 portable rapid oil fume detector (three in one) (hereinafter referred to as the detector) is mainly used to collect the concentration of oil fume emissions in flues and chimneys. This detector meets the requirements of JJG 680-2007 "Verification Regulations for Smoke and Dust Samplers", JJG 518-1998 "Verification Regulations for Pitot Tubes", GB16157-1996 "Determination of Particulate Matter and Sampling Methods for Gaseous Pollutants in Fixed Pollution Source Exhaust", HJ/T48-1999 "Technical Conditions for Smoke and Dust Samplers", and GB18483 "Emission Standards for Cooking Fumes in the Catering Industry". The product has stable performance, easy operation, small portability, and stable flow rate, greatly reducing labor intensity.
Scope of Application
The detector is suitable for fixed flow sampling and concentration measurement of oil fume in fixed pollution sources, as well as measurement of oil fume parameters such as temperature, dynamic pressure, static pressure, and environmental atmospheric pressure and temperature parameters of flue gas, to evaluate the concentration of organized emissions of oil fume.
adopt standards
JJG 680-2007 "Verification Regulations for Smoke and Dust Samplers"
JJG 518-1998 "Verification Regulations for Pitot Tubes"
GB16157-1996 "Determination of particulate matter and sampling methods for gaseous pollutants in exhaust from fixed sources of pollution"
HJ/T48-1999 Technical Conditions for Smoke and Dust Samplers
GB18483 "Emission Standards for Cooking Fumes in the Catering Industry"
Main Features
4.1 Simple on-site operation, direct reading of oil fume, data can be output in more than 2 minutes;
4.2 Electronic flowmeter automatically controls flow and compensates for flow changes caused by voltage fluctuations, resistance, and temperature changes;
4.3 Using high-performance imported diaphragm pumps greatly improves stability, has a long service life, low noise, and overload protection function;
4.4 Measure flow rate and displacement based on pitot tube;
4.5 can measure smoke temperature, static pressure, and dynamic pressure;
4.6 Use high-resolution capacitive touch screen, high sensitivity, intuitive interface, and simple operation;
4.7 Equipped with Bluetooth printer for fast data output;
4.8 Equipped with USB drive export function, automatically generating tables for easy data processing;
4.9 Equipped with a built-in lithium battery, it can be directly measured on site to meet the needs of rapid monitoring;
4.10 Optional noise monitoring function.
working principle
The detector uses a sampling pump to extract oil fume samples. When the gas flows through the oil fume sensor, the oil fume concentration signal is sent to the microprocessor for processing to obtain the concentration. Based on the pitot tube and temperature sensor, the dynamic static pressure and oil fume temperature of the flue and chimney are measured and converted into the flow velocity of the flue and chimney.
technical indicators
The main technical specifications of the detector are shown in Table 1.
Table 1 Main technical indicators of the detector
Main parameters
parameter range
resolution
accuracy
sampling flow
1.0L/min
0.1L/min
Better than ± 2.5%
delay time
0~23h59min
1s
Better than ± 0.2%
/
working power supply
DC12V 2A
store data
≥ 500 groups
warm-up time
1 minute
Built-in lithium battery
7.4V 10Ah
Continuous working time
>15h
noise
<55dB(A)
power consumption
<20W
Overall dimensions
220mm × 160mm × 100mm, smoke gun length 750mm
Total weight
About 3kg