Dust rapid detection instrument, laser scattering method for measuring PM10/PM2.5 concentration analyzer, digital dust meter
Dust rapid detection instrument, laser scattering method for measuring PM10/PM2.5 concentration analyzer, digital dust meter

Dust rapid detection instrument, laser scattering method for measuring PM10/PM2.5 concentration analyzer, digital dust meter

Category:

Instrumentation/Gas analyzer/Dust detector

Model:

LD-5

Brand:

Qingdao Xinye Environmental Protection

model:

LD-5

sampling flow:

0-800

Measurement range:

( 0.001~10) mg/m3

measurement time:

twelve

measurement accuracy:

2%

Product Type:

portable

Working Voltage:

twenty-four

type:

Particle measurement

flow range:

800mi

output method:

two hundred and thirty-two

Temperature control range:

-40-70

noise:

60b

Applicable Industries:

Environment, Third Disease Control, etc

size:

180*94*181

manufacturer:

Qingdao Xinye Environmental Protection

Retail Price

4,980.00USD


重量

kg

  • Product Description
  • model

    LD-5

    sampling flow

    0-800

    Measurement range

    ( 0.001~10) mg/m3

    measurement time

    twelve

    measurement accuracy

    2%

    Product Type

    portable

    Working Voltage

    twenty-four

    type

    Particle measurement

    flow range

    800mi

    output method

    two hundred and thirty-two

    Temperature control range

    -40-70

    noise

    60b

    Applicable Industries

    Environment, Third Disease Control, etc

    size

    180*94*181

    manufacturer

    Qingdao Xinye Environmental Protection

    Description :

    Dust rapid detection instrument, laser scattering method for measuring PM10/PM2.5 concentration analyzer, digital dust meter

    technical indicators:

      Main parameters

      

      parameter range

      

      resolution

      

      accuracy

      

      sampling flow

      

      1L/min

      

      0.01L/min

      

      Better than ± 2.5%

      

      delay time

      

      0~23h59min59s

      

      1s

      

      Better than ± 0.1%

      

      sampling time

      

      1min~99h59min59s

      

      1s

      

      Better than ± 0.1%

      

      PM2.5

      

      (0~30000)ug/m3

      

      1ug/m3

      

      ≤100ug/m3:±10ug/m3

      100~30000ug/m3:±10%

      

      PM10

      

      (0~30000)ug/m3

      

      1ug/m3

      

      ≤100ug/m3:±15ug/m3

      100~30000ug/m3:±15%

      

      particulate matter

      

      (0~30000)ug/m3

      

      1ug/m3

      

      ≤100ug/m3:±20ug/m3

      100~30000ug/m3:±20%

      

      atmospheric pressure

      

      (60~120)kPa

      

      0.1kPa

      

      Better than ± 0.5kPa

      

      ambient temperature

      

      (-40~85)℃

      

      0.1℃

      

      Better than ± 1 ℃

      

      Front pressure of flowmeter

      

      (-35~35)kPa

      

      0.01kPa

      

      Better than ± 2.5%

      

      Temperature before flowmeter

      

      (-55~125)℃

      

      0.1℃

      

      Better than ± 2%

      

      Operating Temperature

      

      (-20~80) ℃

      

      /

      

      /

      

      Operating Humidity

      

      (0~95)% RH without condensation

      

      /

      

      /

      

      working power supply

      

      DC12V2A

      

      store data

      

      ≥ 500 groups

      

      warm-up time

      

      2 minutes

      

      Built-in lithium battery

      

      7.4V 7.8Ah

      

      Continuous working time

      

      >8h

      

      noise

      

      <55dB(A)

      

      power consumption

      

      Battery power supply ≤ 5W

      Charger power supply ≤ 20W

      

      Overall dimensions

      

      210mm×100mm×190mm

      

      Total weight

      

      About 1.8kg

      

    1. Purpose:

      This instrument uses laser scattering method to measure the concentration of PM10/PM2.5 in ambient air, and is suitable for monitoring particulate matter PM10/PM2.5 in indoor environments such as homes, offices, and car cabins.

      2. Equipment

      2.1 Small size, light weight, and low noise;

      2.2 Large display screen, which can clearly display measurement data under strong light;

      2.3 Real time measurement of PM2.5/PM10 and temperature and humidity parameters in the ambient air;

      2.4 Good stability, high sensitivity, and fast testing speed.

      *3. Main technologies

      3.1 PM10 measurement range: parameter range (0-999) μ g/m3, resolution of 0.1 μ g/m3, accuracy of ± 15% and ± 10 μ g/m3 values

      3.2 PM2.5 measurement range: parameter range (0-999) μ g/m3, resolution of 0.1 μ g/m3, accuracy of ± 15% and ± 10 μ g/m3 values

      3.3 Temperature measurement range: parameter range (-20~40) ℃, resolution of 0.1 ℃, accuracy better than ± 1 ℃

      3.4 Humidity measurement range: parameter range (0-99)% RH, resolution 0.1% RH, accuracy better than ± 3% RH

      3.5 Measurement principle: Light scattering measurement method

      3.6 Detection Method: Automatic

      3.7 Response time: ≤ 10s

      3.8 Host weight: ≤ 0.6 kg

      3.9 Power consumption:<1W

      4. Configuration requirements

      1 host, 1 charger, 1 USB data cable, 1 USB flash drive, 2 manuals, 1 certificate of conformity, 1 warranty card, 1 packing list, and 1 protective box.

    AfterSalesService :

    Key words:
    • Dust rapid detector