XY-03FJ portable laser dust detector PM10 PM2.5 dust tester data direct reading
Category:
Instrumentation/Gas analyzer/Dust detector
Model:
LD-5
Brand:
Qingdao Xinye Environmental Protection
model:
LD-5
sampling flow:
0-800
Measurement range:
( 0.001~10) mg/m3
measurement time:
twelve
measurement accuracy:
2%
Product Type:
portable
Working Voltage:
twenty-four
type:
Particle measurement
flow range:
800mi
output method:
two hundred and thirty-two
Temperature control range:
-40-70
noise:
60b
Applicable Industries:
Environment, Third Disease Control, etc
size:
180*94*181
manufacturer:
Qingdao Xinye Environmental Protection
Retail Price
8,600.00USD
重量
kg
- Product Description
-
model LD-5
sampling flow 0-800
Measurement range ( 0.001~10) mg/m3
measurement time twelve
measurement accuracy 2%
Product Type portable
Working Voltage twenty-four
type Particle measurement
flow range 800mi
output method two hundred and thirty-two
Temperature control range -40-70
noise 60b
Applicable Industries Environment, Third Disease Control, etc
size 180*94*181
manufacturer Qingdao Xinye Environmental Protection
Description :
XY-03FJ portable laser dust detector PM10 PM2.5 dust tester data direct reading
XY-03FJ portable laser dust detector PM10 PM2.5 dust tester data direct reading
1 Product Overview
The XY-03FJ portable laser dust detector (hereinafter referred to as the detector) is suitable for rapid determination of inhalable particulate matter concentration in public places, PM10 concentration detection at central air conditioning exhaust outlets, dust concentration detection in labor hygiene aspects such as industrial and mining production sites, monitoring of inhalable dust concentration in environmental protection fields, and evaluation of air purifier purification efficiency.












2. Adopting standards
Determination of Dust Concentration in Air by Light Scattering LD98-1996
Method for determination of inhalable particulate matter (PM10) in the air of public places - light scattering method "WS/T206-2001
TB/T2323-1992 "Determination of relative mass concentration and conversion method of mass concentration of dust in railway operation site air".
3 Main Features
3.1 High measurement accuracy, with an accuracy of up to 1ug/m3 or 0.001mg/m3;
3.2 The electronic flowmeter automatically controls the flow rate with minimal fluctuations;
3.3 Can synchronously display PM2.5, PM10, and TSP concentrations.
3.4 Use a high-resolution 4.3-inch touch screen with high sensitivity, intuitive interface, and simple operation.
3.5 Optional 40mm filter membrane can be used to collect dust samples while monitoring particle concentration.
3.6 Multiple working modes, able to read TWA and STEL directly, can start sampling at a set time, and the obtained data can be stored, queried, or imported into a PC for data processing.
3.7 Equipped with a powerful suction pump, it is more suitable for sampling occasions that require a longer sampling tube (such as the detection of PM10 inhalable particulate matter concentration at the exhaust outlet of central air conditioning).
3.8 Customizable relative particle correction coefficient, capable of storing 20 sets of relative particle correction coefficients, making searching more convenient and efficient;
3.9 Measurement time: 99h59min59s. Setting is more flexible;
3.10 can be started at regular intervals, measured at multiple intervals, and measured continuously multiple times, making the measurement more efficient;
3.11 The particle concentration units ug/m3 and mg/m3 can be switched at any time;
3.12 Generally, there are ≥ 500 sets of data stored in the measurement cycle, and ≥ 50 sets of data stored in the labor hygiene cycle. The storage capacity can be increased according to customer needs;
3.13 Test data can be directly viewed, clear and fast; And it can be exported via USB or printed via Bluetooth;
3.14 The output interface can be customized according to customer needs for RS232 or RS485 output;
3.15 7.4V 7.8Ah high-energy lithium battery ensures stable and efficient operation of the instrument;
3.16 Alarm mode can be set with average concentration alarm and instantaneous concentration peak alarm to meet the needs of different scenarios;
3.17 Optional 4G network, customized transmission platform according to customer needs, or connected to national testing platform;
3.18 USB one click upgrade function, fast and convenient.
4 Working principle:
The light scattering rapid dust analyzer with laser as the light source has multiple cutters to choose from and a built-in filter membrane sampling device, which can collect dust samples while continuously monitoring particulate matter in the air.
technical indicators:
Main parameters
parameter range
resolution
accuracy
sampling flow
1L/min
0.01L/min
Better than ± 2.5%
delay time
0~23h59min59s
1s
Better than ± 0.1%
sampling time
1min~99h59min59s
1s
Better than ± 0.1%
PM2.5
(0~30000)ug/m3
1ug/m3
≤100ug/m3:±10ug/m3
100~30000ug/m3:±10%
PM10
(0~30000)ug/m3
1ug/m3
≤100ug/m3:±15ug/m3
100~30000ug/m3:±15%
particulate matter
(0~30000)ug/m3
1ug/m3
≤100ug/m3:±20ug/m3
100~30000ug/m3:±20%
atmospheric pressure
(60~120)kPa
0.1kPa
Better than ± 0.5kPa
ambient temperature
(-40~85)℃
0.1℃
Better than ± 1 ℃
Front pressure of flowmeter
(-35~35)kPa
0.01kPa
Better than ± 2.5%
Temperature before flowmeter
(-55~125)℃
0.1℃
Better than ± 2%
Operating Temperature
(-20~80) ℃
/
/
Operating Humidity
(0~95)% RH without condensation
/
/
working power supply
DC12V2A
store data
≥ 500 groups
warm-up time
2 minutes
Built-in lithium battery
7.4V 7.8Ah
Continuous working time
>8h
noise
<55dB(A)
power consumption
Battery power supply ≤ 5W
Charger power supply ≤ 20W
Overall dimensions
210mm×100mm×190mm
Total weight
About 1.8kg
AfterSalesService :